  1. Replies
    7
    Views
    232

    Seems like Rotolocks are going to become a thing...

    Seems like Rotolocks are going to become a thing of memories soon.
  2. Replies
    17
    Views
    545

    Could be an old Williams or Air Ease outdoor...

    Could be an old Williams or Air Ease outdoor unit. Or even an American Furnace (AFCO) that matched the furnace. They were green and front discharge.
  3. Replies
    7
    Views
    232

    The rotolocks were on the old Climatuff GE...

    The rotolocks were on the old Climatuff GE compressors.
  4. Propane probably won't raise the house 16 in 2...

    Propane probably won't raise the house 16 in 2 hours!
  5. Replies
    17
    Views
    545

    Judging from my literature, that model was sold...

    Judging from my literature, that model was sold for a long time in the 70s. Since it says American Furnace on it, I'd guess early 70s. Still got a Singer outside?
  6. Air source temp drops as outdoor temp drops. 12...

    Air source temp drops as outdoor temp drops. 12 rise seems a bit low for 20s out but depends on airflow. On your water source unit, the heat output will vary a bit with the loop water temp but temp...
  7. No snow? Noticed not on feet/pump ups. Still...

    No snow? Noticed not on feet/pump ups. Still would have defrost water come out.
  8. Is there any backup heat?

    Is there any backup heat?
  9. Funny sound! Where are you located?

    Funny sound! Where are you located?
  10. Replies
    16
    Views
    428

    The X13 doesn't increase speed to maintain CFM...

    The X13 doesn't increase speed to maintain CFM though. They'll drop CFM as static increases just like a PSC.
  11. Trane usually changes a letter to indicate a...

    Trane usually changes a letter to indicate a change in the unit, the letter after the 036 size. From what I can find, the 036C is communicating. Nothing I found on the 036E says it is.
  12. We've changed plenty of pressure switches this...

    We've changed plenty of pressure switches this winter. The components used in today's furnaces tend to come from 3rd world countries and doesn't hold up like they used to. And water in the switch...
  13. Replies
    15
    Views
    519

    Probably got fed up with the failures of the CR...

    Probably got fed up with the failures of the CR ones. I remember Turkey Day 2013. The on call found 3 sticking pressure switches on new furnaces. 3 different brands. Same mfr of the switch in Costa...
  14. Replies
    15
    Views
    422

    Dang, I could do a simple whole house J in 30-45...

    Dang, I could do a simple whole house J in 30-45 minutes, especially on a ranch.

    33K to heat 2000 in Minniesota doesn't make sense. Seems awfully small. My 970 sq ft well built house in Indy can...
  15. Replies
    15
    Views
    519

    Just got the latest and greatest Lennox/Allied...

    Just got the latest and greatest Lennox/Allied .9" pressure switch in. Made by Honeywell in Mexico!
  16. We had a Bryant that had high voltage go through...

    We had a Bryant that had high voltage go through the low voltage circuit, fried a bunch of stuff. Turns out the wire to the defrost stat had rubbed through a compressor lead putting 120V into it....
  17. Replies
    5
    Views
    183

    When the temp gets below freezing, the heat pump...

    When the temp gets below freezing, the heat pump has a hard time keeping up. MOST installers use an outdoor sensor to lock out the pump below around 30. A few stats on WiFi get the local temp from...
  18. Replies
    15
    Views
    514

    I wouldn't spend the money for an oversized 2...

    I wouldn't spend the money for an oversized 2 stage. All you are getting is a pricey 1 stage. Mine is oversized, went through the -15 stuff last winter with high switched off with a toggle switch....
  19. Replies
    5
    Views
    183

    Is there an outdoor sensor that turns the unit...

    Is there an outdoor sensor that turns the unit over to gas heat in cold weather? Also ask them if they hooked up defrost heat to temper the cold air in a defrost.
  20. There was a brief time that the 16i was...

    There was a brief time that the 16i was communicating. That was several years ago so if this is a surplus unit or been sitting around some time, he could have that model.
  21. Replies
    15
    Views
    519

    I never heard of Costa Rica until I saw it on a...

    I never heard of Costa Rica until I saw it on a pressure switch!
  22. Microchannel in & out, thrilling!

    Microchannel in & out, thrilling!
  23. Replies
    15
    Views
    514

    What's the heat gain/loss numbers for that place?...

    What's the heat gain/loss numbers for that place? I'm guessing they will way oversize!
  24. Replies
    3
    Views
    257

    400 CDD? Doesn't sound like anything over 13/14...

    400 CDD? Doesn't sound like anything over 13/14 SEER makes sense.
  25. Replies
    15
    Views
    519

    Apparently that's another number for a 93W13. So...

    Apparently that's another number for a 93W13. So no, we haven't had problems. Now the pressure switch on those 1 stage 95s, that's another story :(
  26. Replies
    3
    Views
    162

    Try a United Refrigeration.

    Try a United Refrigeration.
  27. Replies
    15
    Views
    519

    What's Lennox's part #? Lot of them are the same...

    What's Lennox's part #? Lot of them are the same as Allied and we haven't lost any yet, knock on wood. The A95 single stage upflow uses a 93W13.
  28. Replies
    7
    Views
    203

    Yes, nice to wire a HW to the IAQ! Seems to me...

    Yes, nice to wire a HW to the IAQ!

    Seems to me Thermastor made or makes Honeywell.
  29. Replies
    29
    Views
    1,244

    The Focus Pro will not stage the backup, few...

    The Focus Pro will not stage the backup, few stats do. Have to get into some of the Vision Pro or Prestige models to do that.
  30. Replies
    5
    Views
    253

    I had one on Christmas Eve could years ago. Still...

    I had one on Christmas Eve could years ago. Still dressed in my go to church goodies. Rheem 90, had a run of sticking switches so I knew what to do. I say to the customer, watch this, and gave the...
  31. Small gas pack outside ducted into crawl with...

    Small gas pack outside ducted into crawl with floor vents.

    Or little gas furnace in the crawl or attic with split A/C. Sorta depends upon how much room in crawl and attic. I'd guess if they have...
  32. WHY???? Besides, unusual to find a 6 ton...

    WHY???? Besides, unusual to find a 6 ton residential single phase air handler. Got any model #s?
  33. Replies
    13
    Views
    485

    Direct vent (2 pipe) is 12" in the US.

    Direct vent (2 pipe) is 12" in the US.
  34. Replies
    9
    Views
    264

    Most heat pumps use a timer. When the unit has...

    Most heat pumps use a timer. When the unit has run x minutes, the board looks to see if the coil is below freezing. If so it will defrost, needed or not. If the outdoor temp is below 40-45, the coil...
  35. Replies
    16
    Views
    491

    It is automatic. It's logic based on time and...

    It is automatic. It's logic based on time and temp, you don't have to adjust anything. It will keep you warm.
  36. Replies
    9
    Views
    264

    Yea, but defrosts are longer than 10-15 seconds....

    Yea, but defrosts are longer than 10-15 seconds. What kind of control/thermostat do you have?
  37. With return air that cold, flue gas will condense...

    With return air that cold, flue gas will condense in the primary heat exchanger causing rust & corrosion. Don't know why the old one didn't warn you put it is an issue to be aware of.
  38. They just hang lose in the control compartment....

    They just hang lose in the control compartment. The demand boards do let a lot of frost build up before they go into defrost. Sure beats the timers constantly defrosting a clean coil.
  39. Replies
    5
    Views
    239

    Something wrong both places. My dual fuel was on...

    Something wrong both places. My dual fuel was on HP only at 26 out and the pump warmed me up from 63 to 66 without backup. Your heat pump ought to do better than it is and you sure should have a...
  40. Replies
    8
    Views
    253

    I can't find anything either. This in the US? I...

    I can't find anything either. This in the US? I didn't know Nordyne sold minis.
  41. Replies
    39
    Views
    1,202

    The timer cripples the comfort a 2 stage furnace...

    The timer cripples the comfort a 2 stage furnace is capable of. Which sounds better in bitter weather? Constant cycling between low, high & off or long run cycle on quiet, gentle low fire? Do you...
  42. Replies
    9
    Views
    337

    G like any other system. BUT be sure you are...

    G like any other system. BUT be sure you are using the G with the black stripe if a variable speed air handler. Green with yellow stripe is dehumidify. Purple is defrost heat to W1.
  43. Replies
    7
    Views
    355

    Likely just his local Bryant or Carrier supplier...

    Likely just his local Bryant or Carrier supplier that doesn't stock much. Locally both of ours are fine to deal with. I don't care for our Amana supplier however but there is little of it sold...
  44. Replies
    4
    Views
    256

    I'm still waiting for a Trane HX that neither...

    I'm still waiting for a Trane HX that neither Trane nor A-S distributor stocked locally. Luckily they aren't down.

    At 6 years if registered, a Friggie original owner should get a new furnace.
  45. The unit is in cool mode. The outdoor coil is the...

    The unit is in cool mode. The outdoor coil is the high side so it doesn't matter what the indoor coil does. Sure wish my blower shut off on start up, keep that blast of cold air from nailing me...
  46. There's gotta be at least 1 "wallie" out that...

    There's gotta be at least 1 "wallie" out that way. Lotta boilers out there.
  47. I've had experience with a couple of steamers...

    I've had experience with a couple of steamers with not good results. Have not tried the Aprilaire 800. Personally I'd do a bypass hum. If you need capacity, the General 1099LHS has lots higher output...
  48. Replies
    16
    Views
    696

    Since the N coils are murder to uncase, we use...

    Since the N coils are murder to uncase, we use ADP with our Rheems. No leaks, lots of plugged TXVs.
  49. It was the new Vision Pro TH8321R and the...

    It was the new Vision Pro TH8321R and the equipment module. Needed wireless. Otherwise same principle as the Prestige.
  50. Replies
    3
    Views
    247

    600 for sure

    600 for sure