Search:

Type: Posts; User: jdservice

Search: Search took 0.00 seconds.

  1. Replies
    21
    Views
    1,781

    Good thing its only produce!! Next they will do...

    Good thing its only produce!! Next they will do the same with the meat case at Thanksgiving....
  2. Replies
    60
    Views
    12,416

    Tif ZX1 will find the leak.

    Tif ZX1 will find the leak.
  3. Replies
    53
    Views
    4,187

    Split and wash out the "inside condensor". Pull...

    Split and wash out the "inside condensor". Pull the top off where the condensor fans are located. Set the whole condensor fan assembly on the top of the unit. Thats why you have all that extra...
  4. Thread: Racked

    by jdservice
    Replies
    35
    Views
    2,868

    Sounds like the TXV is not working. Maybe try...

    Sounds like the TXV is not working. Maybe try replacing the powerhead. Its a lot easier then replacing the valve.
  5. Replies
    8
    Views
    761

    Had new E2 installed during recent upgrade at one...

    Had new E2 installed during recent upgrade at one of my accounts by another contractor. The mechanic from Source was Justin. Cool guy that I met in Petaluma.
    More power to them for trying to save my...
  6. Replies
    12
    Views
    1,459

    We did a major rebuild of a 1959 Ray Winther...

    We did a major rebuild of a 1959 Ray Winther installed TD system in San Rafael,Ca last spring. Due to space concerns at the market the customer chose to rebuild as opposed to replacing. It was a...
  7. Replies
    194
    Views
    21,020

    If you install a sight glass on the discharge...

    If you install a sight glass on the discharge line of compressor. It said Hill on that guys shirt.
  8. Replies
    194
    Views
    21,020

    If you install a new lineup of meat cases and...

    If you install a new lineup of meat cases and your crew cuts one of the rails with a torch and blows molten steel
    all over the customers new floor tiles. I think they will be paying to replace about...
  9. Replies
    11
    Views
    1,138

    You need to have a suction accumulator on low...

    You need to have a suction accumulator on low temp applications and with R-22 it needs all the cold it can get on the hot days. Should be insulated. Also crank case heaters are installed on most low...
  10. Replies
    2
    Views
    594

    Try setting all the head pressure controls for a...

    Try setting all the head pressure controls for a 70 degree condensing temp. This will most likely be quite a bit lower then it is set for now and will save money. Wash out the condensors 2 times per...
  11. Replies
    7
    Views
    1,214

    Sounds like a problem with the design, the piping...

    Sounds like a problem with the design, the piping or both.
    What suction pressure did those units run during normal operation.
  12. Replies
    17
    Views
    1,540

    Those compressors don`t have handles on them for...

    Those compressors don`t have handles on them for a reason.
    Chain fall is the only way roll. I have changed a couple of 3D 10HP solo but not by choice. Both were also one on one systems. To hard to...
  13. Thread: rmcc panel

    by jdservice
    Replies
    6
    Views
    874

    What questions do you have? I have a manual handy.

    What questions do you have? I have a manual handy.
  14. Replies
    2
    Views
    550

    Have a Recold tube bundle in a JC-165 to change...

    Have a Recold tube bundle in a JC-165 to change out. Bundle is solid rock and has already had passes cut out of the low temp due to leaks. The new bundle is 1600 pounds shipping weight. I think we...
  15. Thread: wages

    by jdservice
    Replies
    2
    Views
    801

    42.00 dollars per hour plus paid health and...

    42.00 dollars per hour plus paid health and welfare and paid pension and paid 401A supplemental pension. Total package around 60.00 dollars per hour. I worked 3000 hours last year doing only market...
  16. Replies
    22
    Views
    1,546

    How about the Einstein E2. It seems to work well....

    How about the Einstein E2. It seems to work well. Really do like the RMCC. Just started up a store in 04 that had 6 RMCC controllers. We do have one store in our area with Danfoss. Have had no...
  17. Replies
    5
    Views
    760

    Dave are you tellin me you run the evaporator...

    Dave are you tellin me you run the evaporator temp 10 degrees above design and that works without a problem. What kind of product do you get in the bin? Have been told by Howe to lower temp to -10...
  18. Replies
    22
    Views
    1,546

    Sorry Dave I just have a sour taste after being...

    Sorry Dave I just have a sour taste after being told by the aftermarket parts distributer for the "global" company I worked for that if I had a bad Sporlan Sol. coil that it would be more profitable...
  19. Replies
    50
    Views
    5,140

    Our shop is in Santa Rosa. We pretty much cover...

    Our shop is in Santa Rosa. We pretty much cover all of the wine country down to the bridges. We don`t cross the bridges, plenty of work up here. Does everybody know about the TD system were talking...
  20. Replies
    41
    Views
    12,389

    Had my first ZX1 for two years with no problems....

    Had my first ZX1 for two years with no problems. Started having charging problems and replaced battery. I think the key is to have a sensor for R-22 and blends and another one for HFC refrigerants. I...
  21. Replies
    22
    Views
    1,546

    Lets start direct depositing all of our money...

    Lets start direct depositing all of our money into Finlands economy, and while were at it lets give praise to GE for making 9W motors in China. Bet those workers in Garrett Indiana were stoked about...
  22. Replies
    5
    Views
    760

    Has any body out there had problems with Howe ice...

    Has any body out there had problems with Howe ice flakers connected to rack systems? Got a 3000 RLE connected to a 6 compressor Protocol system. Lots of problems with the barrel icing up. Have been...
  23. Replies
    50
    Views
    5,140

    We still have plenty of TD systems running in...

    We still have plenty of TD systems running in northern CA.
    We still have an original Ray Winther install from the early 1960's that is still running!. I have seen Raleys retrofit a TD to R-404A!...
  24. Replies
    41
    Views
    12,389

    Well if Raleys uses it, they must be the...

    Well if Raleys uses it, they must be the best.LOL. What a hoot. Tif ZX-1 will find more leaks then you will want to fix. It will get you close enough to find it with either soap bubbles or with R-22...
  25. Replies
    19
    Views
    1,783

    Shoppers just go about their buisness while the...

    Shoppers just go about their buisness while the SMOKE escapes from the kneeknocker case.Do I smell a faint odor of juicy fruit gum in the air? At least its O-ZONE friendly. Nice day to own the...
  26. Replies
    6
    Views
    880

    If it was ordered OEM then the tubes would be...

    If it was ordered OEM then the tubes would be gold plated and the wrong coil would be delivered.Just keep pumping 502 in there junior and we'll find a leak one of these days. Added 850 pounds and...
  27. Replies
    12
    Views
    1,937

    Worked on 2 WHIP racks at a market in San...

    Worked on 2 WHIP racks at a market in San Francisco. Was told the "we hope it performs" By former GHV employee. Have seen one POLAR rack. Overkill on the control panel is all I can remember. Oh and...
  28. Replies
    4
    Views
    919

    Fluke 52. Has a nice clamp on probe for checking...

    Fluke 52. Has a nice clamp on probe for checking superheat,has a probe you touch the discharge line for discharge temp. Sometimes the little bead probes for checking case temps don't stay where you...
  29. Replies
    12
    Views
    1,937

    A Kimmel Motz WHIP rack- we hope it performs.

    A Kimmel Motz WHIP rack- we hope it performs.
  30. Replies
    52
    Views
    5,792

    Bitter Mechanic- A mechanic that starts breaking...

    Bitter Mechanic- A mechanic that starts breaking freezer case glass doors with a hammer with hopes of the store not ever calling for service again.
  31. Replies
    9
    Views
    1,748

    Your question should be directed to your local...

    Your question should be directed to your local supply house.
  32. Replies
    13
    Views
    3,880

    You have pressures running W/I freezer temp. You...

    You have pressures running W/I freezer temp. You should try getting the suction pressure up to W/I cooler design. Maybe 20 to 25 degrees. Sounds like a TXV problem or the evap.coil is iced up.
  33. Replies
    17
    Views
    1,544

    Proper meat case operation is critical in any...

    Proper meat case operation is critical in any market. Especialy if it is a multi or single deck open case. The butcher cuts it and puts it in the case and if its not working correctly he knows the...
  34. Replies
    6
    Views
    1,286

    This type of freezer case does not work very...

    This type of freezer case does not work very well. If it is the same type as the ones I have experience with it is basicly a W/I freezer box that has very large doors and is loaded from the front....
  35. Replies
    6
    Views
    880

    Anyone know where to get replacement coils made...

    Anyone know where to get replacement coils made for replacing OEM leaky aluminum coils on service fish case?
    model NESSH8U
  36. Replies
    6
    Views
    1,286

    If -20 suction temp only gets you 8 degree box...

    If -20 suction temp only gets you 8 degree box temp you either have iced up evap. coils or TXV problems. Check superheat at coils and make sure its low. I hope these are standard type W/I freezer...