    Interesting. Thanks for the update! Seems...

    Interesting. Thanks for the update!

    Seems like it still isn't auto-setup like the carrier option but at least we can use it now with the iComfort Wifi.
  2. Replies
    11
    Views
    1,025

    Do you have any additional information about the...

    Do you have any additional information about the iComfort Zoning Panel? I have been waiting for this since the original iComfort has come out.

    Thanks.
  3. Replies
    0
    Views
    108

    Lennox Communicating Zoning

    Does anyone know if Lennox will be releasing a communicating zoning system that works with the iComfort Wi-Fi and SLP98V? I would hate to give-up my iComfort Wi-Fi to use the Harmony III zoning...
  4. Replies
    7
    Views
    642

    This is the Ask Our Pro's forum, and only Pro...

    This is the Ask Our Pro's forum, and only Pro members that have been vetted by the AOPC may post advise, commentary, or ask questions of the OP here.

    You can find the rules for posting and...
  5. Replies
    3
    Views
    524

    This is the Ask Our Pro's forum, and only Pro...

    This is the Ask Our Pro's forum, and only Pro members that have been vetted by the AOPC may post advise, commentary, or ask questions of the OP here.

    You can find the rules for posting and...
  6. Replies
    1
    Views
    287

    This is the Ask Our Pro's forum, and only Pro...

    This is the Ask Our Pro's forum, and only Pro members that have been vetted by the AOPC may post advise, commentary, or ask questions of the OP here.

    You can find the rules for posting and...
  7. Water pad is new, water is turned on and flowing...

    Water pad is new, water is turned on and flowing (connected to hot) and winter mode is turned on. It is connected to an SLP98V so I'm thinking the low CFM and heat that is constantly runs at is not...
  8. Question about by-pass humidifier and furnace air filter

    With my bypass humidifier dumping the humid air into the return airflow, which is then filtered by a Merv 16 air filter ... wouldn't all the humidity be caught by the filter?

    I'm having a hard...
  9. You need to re-read my question.

    You need to re-read my question.
  10. TB - I think you misunderstood my problem. The...

    TB - I think you misunderstood my problem. The only way I can lower the humidity setting is by lowering the dehumidify setting (because of the deadband - but of course, de-humidify can only be...
  11. Lennox iComfort WiFi - Dew Point Control Humidity Setting

    Hi,

    Does anyone know how to adjust the humidity setting when dew-point control is on? It seems that I can only adjust the dehumidify setting which will them move the humidify setting within a 5%...
  12. Replies
    24
    Views
    2,452

    So I think I've finally figured this out, with no...

    So I think I've finally figured this out, with no help of the Lennox dealer.

    Looked up the installation manual on the SLP98V. It clearly states that the vent from the condensate trap must not...
  13. Replies
    24
    Views
    2,452

    I had the guys come out to inspect. What a waste...

    I had the guys come out to inspect. What a waste of two visits and $$$ for "annual cleaning". On his first visit he agreed there may be an issue with water in the inducer. He removed the inducer...
  14. ... and 95%+ of the "pros" that have no idea as...

    ... and 95%+ of the "pros" that have no idea as well?
  15. My question was erased when revising the above......

    My question was erased when revising the above... it is...

    In the installer menu there are two options.

    1. Modulating Gas Heat Step Change PI Gain; and
    2. Modulating Gas Heat Steady State PI...
  16. Any Lennox Pro's can answer my iComfort Wi-Fi Modulating Question?

    Load−tracking Variable Capacity FAQs
    (SLP98V only)

    What is Load−tracking Variable Capacity?
    When an SLP98 Furnace is connected to an icomfort Wi−Fi thermostat, the thermostat takes complete...
  17. Replies
    24
    Views
    2,452

    Ok thanks

    Ok thanks
  18. Replies
    24
    Views
    2,452

    Any idea what normally causes this then?

    Any idea what normally causes this then?
  19. Replies
    24
    Views
    2,452

    Just received this from my thermostat... I guess...

    Just received this from my thermostat... I guess it related to water inside the inducer?

    Dear icomfort user,

    The icomfort system has generated a new alert. Below is some more detailed...
  20. Replies
    24
    Views
    2,452

    I can definitely hear some water hitting the...

    I can definitely hear some water hitting the inducer fan blades - I'm trying to figure out if this is a normal condition for these types of furnaces so I don't have my dealer come around and tinker...
  21. Replies
    24
    Views
    2,452

    Enough to hear?

    Enough to hear?
  22. Replies
    24
    Views
    2,452

    I had the tech come in today. He didn't know what...

    I had the tech come in today. He didn't know what was causing the condensation and said he needed to circle back with lennox.

    Question for the pros - should the draft inducer be totally bone dry,...
  23. Replies
    24
    Views
    2,452

    It was installed in February of this year (2012).

    It was installed in February of this year (2012).
  24. Replies
    24
    Views
    2,452

    Lennox SLP98V - Gurgling Noise

    Hi,

    Winter is coming and we have started using our furnace. I notice that our SLP98V has a gurgling noise at the fan inducer (sounds like water/condensate is swishing around in there). The...
  25. Replies
    22
    Views
    1,681

    If I use an independent ventilation controller...

    If I use an independent ventilation controller and command it to run the infinity system by the G terminal, if the infinity system is off, won't all the zone dampers also be in the "closed" position...