    So did you actually see flame with the combustion...

    So did you actually see flame with the combustion blower off? When the combustion blower did run and the burner fired, what was the gas pressure?
  2. Replies
    22
    Views
    876

    [QUOTE=mixsit;18991981]'Cause I didn't do this.....

    [QUOTE=mixsit;18991981]'Cause I didn't do this..

    You stated in your original post that you did.
  3. Thread: Evap coil repair

    by hands
    Replies
    8
    Views
    440

    I have made repairs like that on condenser coils....

    I have made repairs like that on condenser coils. I used a hacksaw blade to cut the copper tubing and blew nitrogen through the system to remove the shavings. I then used a piece of larger tubing...
  4. Thread: HVAC Consultant

    by hands
    Replies
    4
    Views
    520

    A lot of travel time and long wait time for...

    A lot of travel time and long wait time for someone to let you in the fenced area. I had a service call at one and couldn't even drive my van up the very long and steep hill. The maintenance guy that...
  5. Replies
    19
    Views
    949

    Most process chiller water loops are not a sealed...

    Most process chiller water loops are not a sealed loop. So there will be evaporation over time. If it is a glycol mixture, you will need to check the glycol % when the water loop is low because the...
  6. Replies
    17
    Views
    1,328

    I have seen a lot of problems with Trane units...

    I have seen a lot of problems with Trane units over the last several years. I have a customer that has mostly Trane units. In the last four years, there have had nine RTU's installed. Eight of them...
  7. Replies
    3
    Views
    355

    If the subcooling looks good and you don't have...

    If the subcooling looks good and you don't have an airflow problem, you will have to adjust the TXV. But I would make sure the evaporator is clean. I just went through similar problem with a RTU,...
  8. Thread: BDP RTU problem

    by hands
    Replies
    5
    Views
    553

    Well, I got back to the unit today and found that...

    Well, I got back to the unit today and found that the evaporator coil was dirty, especially on the lower half which is circuit #1. So I would say it did have ice on it the other day when I was having...
  9. Thread: BDP RTU problem

    by hands
    Replies
    5
    Views
    553

    I haven't been able to check the unit any...

    I haven't been able to check the unit any further. It is possible that circuit #1 had ice on it, but circuit #2 ran fine. I didn't check it out very good due to the rain. I hope to get back to it...
  10. Thread: BDP RTU problem

    by hands
    Replies
    5
    Views
    553

    BDP RTU problem

    I was doing the PM on BDP RTU, M# 580DEV120180AAAA. I found that ckt#1 was tripping on low pressure and the suction line was frosted from the evaporator to the compressor. I added 1 lb. of R-22 which...
  11. You should check it at the outlet of each...

    You should check it at the outlet of each evaporator coil as you would with any system. I would setup each circuit by itself, then run both circuits together and check them again.
  12. Replies
    2
    Views
    257

    filter-drier pressure drop.

    I was just wondering what kind of pressure drop across a filter-drier core you guys change the core. It seems that I remember reading that when it gets to 3 psi above the starting pressure drop, you...
  13. Thread: leak testing ?

    by hands
    Replies
    12
    Views
    601

    I think it's just the temperature difference. If...

    I think it's just the temperature difference. If you have the time, you could watch the pressure to see if it goes back up to 170 psi as the ambient temperature goes up. Put I would start evacuating,...
  14. Replies
    8
    Views
    538

    I have repaired several leaks on the factory 90...

    I have repaired several leaks on the factory 90 right off the compressor. This is very common on Trane equipment. I have always just brazed over the leak, but put a heavy coating of sil-foss over...
  15. Replies
    12
    Views
    736

    Staybrite #8 will not stick to braze, I have...

    Staybrite #8 will not stick to braze, I have tried it. But you can braze over staybrite, and yes I have done it.
  16. Replies
    34
    Views
    1,968

    Why don't you just braze in your fitting and then...

    Why don't you just braze in your fitting and then braze around the soft solder fittings that you are worried about. You can braze right over solder with no problem. You could also just cut out some...
  17. Thread: Laptops

    by hands
    Replies
    7
    Views
    608

    My company gave all Service Techs net books to...

    My company gave all Service Techs net books to use. We do electric service reports with them.
  18. Thread: Work Pants

    by hands
    Replies
    52
    Views
    4,172

    I like Dickies Carpenter jeans. They are made...

    I like Dickies Carpenter jeans. They are made well and hold up good.
  19. I would think every service tech could sweat...

    I would think every service tech could sweat loose a solder joint and re-solder it. If they couldn't, they would have a problem changing a compressor. As for the solders he mentioned, Stay-Brite #8...
  20. I would just sweat it loose, clean the joint...

    I would just sweat it loose, clean the joint good, flux it and solder it with 45% silver solder.
  21. Replies
    5
    Views
    317

    I get them from Air Filters Direct in Cincinnati.

    I get them from Air Filters Direct in Cincinnati.
  22. Replies
    30
    Views
    1,884

    Why don't you just send a tech that knows what...

    Why don't you just send a tech that knows what he's doing, recover the charge, replace the liquid line filter drier, evacuate the circuit and charge it. This would be the right thing to do and would...
  23. Thread: r22 at 300 psig?

    by hands
    Replies
    30
    Views
    1,949

    With a space temperature that low, the suction...

    With a space temperature that low, the suction pressure will be low and the evaporator coil will freeze up. They might be trying to keep the head pressures up which will also make the suction...
  24. Replies
    18
    Views
    837

    Sounds like one fan is moving all of the air and...

    Sounds like one fan is moving all of the air and the other fan is freewheeling. Try starting out with both fans at say 20 Hz and increase them at the same time and see if the amps stay closer. Have...
  25. Replies
    4
    Views
    357

    I attended a class on compressor rebuilds. The...

    I attended a class on compressor rebuilds. The guy giving the class said that a full remanufactured compressor, even from Carlyle, still uses mostly used parts. He said that they only replace the bad...