  1. I would have to ask for a little trust on that...

    I would have to ask for a little trust on that one... You have no reason to but... I have the install guide, which clearly show the inside holes as primary and the outer as secondary. If you remove...
  2. Beshvac - I could have perhaps worded that...

    Beshvac - I could have perhaps worded that better. I have a inspection camera / boroscope I had worked into the coil case and I was looking at the backside of the primary drain.

    Never forget the...
  3. Vstech - Tee into coupling- that's just temporary...

    Vstech - Tee into coupling- that's just temporary while I tested this out. I cut the original lines and left the existing p trap in place and test fitted everything. The entire p-trap will be...
  4. :grin2: Better picture below. The picture is...

    :grin2: Better picture below. The picture is not level due to my picture taking. Cant figure out how to take museum quality shots like my daughter while hanging off a ladder by one toe in a...
  5. Condensate P trap not working with Capped clean out.

    Discovered this weekend My primary condensate drain was not working after noticing water in the emergency / auxiliary drain pan. The line did not have a clean out before the P trap (see attached...
  6. Thank you for the response. I eventually located...

    Thank you for the response. I eventually located the manual for the coil, which basically says a p trap with no air vent before the trap. Local code requires a. Vent after the trap. The manual says...
  7. Replies
    0
    Views
    165

    Dual XV80 systems incorrectly wired?

    Two Story house with two units. Both are using a XV80, gas heat, with different outside units

    I just replaced a XL16I single stage outdoor unit with a XR16. Who knew a fans peed controller bad...
  8. Can't seem to delete this post... Please ignore...

    Can't seem to delete this post... Please ignore the above. I exceed the time limit for a edit and was unable to revise, and have yet to find the delete command.. Here is the revised post.

    While...
  9. Condensate drain clarification before repair.

    While troubleshooting a humidity problem I discovered I have a P trap that is not draining. Since there is no clean out I will have to cut the PVC to access it for cleaning and install a clean out....
  10. Replies
    18
    Views
    6,134

    Thanks. The vendor was the one who suggested we...

    Thanks. The vendor was the one who suggested we could keep the 12 year old XV80. He said its no different from the current model
  11. Replies
    18
    Views
    6,134

    ok. The outside unit is 4TTR6036B1000A. The coii...

    ok. The outside unit is 4TTR6036B1000A. The coii is a 4TXCB036BC3HCBA. I think the XV 90 (Mfg in 2001) is Tud080b9v3s.

    One of my primary concerns was to get as efficient as possible, preferrably...
  12. Replies
    18
    Views
    6,134

    As you area trane delaer let me expand on that...

    As you area trane delaer let me expand on that question. The model is 4TTR6036B1000A (single stage). According to the dealer I talked to , based on the trane literature guide he has, this XR16 is a...
  13. Replies
    18
    Views
    6,134

    The XR16 comes in a single stage and a 2 stage....

    The XR16 comes in a single stage and a 2 stage. My unit I am considering is a single stage. Thats based on the model number ( 4TTR6036B1000A) and the fact that the box says single stage :)
  14. Replies
    18
    Views
    6,134

    Trane XL16i vs XR16

    I need to replace my outside condensor unit and inside coils. 3 ton unit , xv90 furnace. I plan to keep the XV90 furnace section as it is still in great shape.

    I have one shop pushing the XL16i ....
Results 1 to 14 of 14