  1. 14x8 is about 2/3s the size you should have in sq...

    14x8 is about 2/3s the size you should have in sq ft. 20x8 would be much better.
  2. Thread: CapSizing

    by beenthere
    Replies
    21
    Views
    435

    Please put your email address in your profile,...

    Please put your email address in your profile, they are not allowed in post, thank you.
  3. Replies
    25
    Views
    566

    Any good commercial electrician can g you the 120...

    Any good commercial electrician can g you the 120 you need. For us to tell you how would be over stepping thee DIY boundary.
  4. Thread: CapSizing

    by beenthere
    Replies
    21
    Views
    435

    Not good for the compressor or fan motor. Shorter...

    Not good for the compressor or fan motor. Shorter life span.
  5. Replies
    21
    Views
    578

    Unless you have allergies, just use MERV 8...

    Unless you have allergies, just use MERV 8 filters.
  6. Replies
    8
    Views
    221

    Some schools don' teach electrical diagnostics....

    Some schools don' teach electrical diagnostics. He may have been asking how to do electrical diagnostics.

    522, get your post count up to 15, and apply for pro membership, where you can get in deph...
  7. Replies
    16
    Views
    362

    Sensor/humidistat location is okay. A bypass...

    Sensor/humidistat location is okay.

    A bypass would do a better job. Not possible for me to say if it would be enough or not though.
  8. Replies
    16
    Views
    362

    Humidifier looks to be mounted on the return....

    Humidifier looks to be mounted on the return. That is okay for a bypass, but the 700 is a powered humidifier, and doesn't humidifier as well when mounted on the return.
  9. Replies
    21
    Views
    578

    You have a low air flow issue. And that is...

    You have a low air flow issue. And that is causing your high stack temp. What kind of air filter are you using.
  10. It mimics the anticipator of non digital...

    It mimics the anticipator of non digital thermostats. Simply attempts to delay the on and off of the equipment to get the set CPH based on previous run cycles. Its more accurate when the heat loss or...
  11. Not with a good Honeywell thermostat. Temp over...

    Not with a good Honeywell thermostat. Temp over rides cycles per hour. So no unpleasant temp swings setting it to 1 CPH.
  12. Replies
    16
    Views
    362

    Is it mounted before or after the humidifier. And...

    Is it mounted before or after the humidifier. And is the humidifier mounted on the supply or return. Is the water line directly attached at the water heater, or is it tapped into a hot water line...
  13. Replies
    5
    Views
    186

    Please put your email address in your profile,...

    Please put your email address in your profile, they are not allowed in post. Thank you.
  14. Replies
    10
    Views
    541

    Mismatched indoor and outdoor unit won't kill a...

    Mismatched indoor and outdoor unit won't kill a compressor in a year. Lots of apartment complexes have mismatches that are running since 2006.

    However, a heat pump does have some problems with a...
  15. Replies
    16
    Views
    362

    Have it repiped to the hot water line off the...

    Have it repiped to the hot water line off the water heater.
  16. Replies
    3
    Views
    216

    Call owner of company, and tell him what happened.

    Call owner of company, and tell him what happened.
  17. Replies
    9
    Views
    330

    Normal.

    Normal.
  18. Replies
    16
    Views
    362

    Does the furnace have long or short on...

    Does the furnace have long or short on cycles/times.
  19. Replies
    13
    Views
    605

    In the original post, you posted 100, not 110.

    In the original post, you posted 100, not 110.
  20. Replies
    21
    Views
    578

    LOL, a pretty dismal one.

    LOL, a pretty dismal one.
  21. Replies
    7
    Views
    182

    Its best to use the EHD. Most line sizing charts...

    Its best to use the EHD. Most line sizing charts don't use inches for sizing CSST, just the EHD.
  22. Replies
    21
    Views
    578

    His oil company doesn't even do adjustments. I...

    His oil company doesn't even do adjustments. I doubt they could make any nozzle other then factory spec work.
  23. Replies
    7
    Views
    182

    Gastite uses the larger corrugation as its...

    Gastite uses the larger corrugation as its measurement, and Trackpipe uses the smaller corrugation for its measurement. So 1/2" Gastite is a smaller EHD then 1/2" Tackpipe.
  24. Replies
    7
    Views
    182

    1/2 PSI, as in an actual 14". 1/2 track pipe will...

    1/2 PSI, as in an actual 14". 1/2 track pipe will carry it, Gastite would be pushing it.

    Better to run 3/4", that allows for the pressure drop through bends.
  25. Replies
    13
    Views
    479

    Put an outdoor stat on an set it to hold out...

    Put an outdoor stat on an set it to hold out second stage until X temp.