    Thanks for the quick response Russell. I talked...

    Thanks for the quick response Russell. I talked to Kris, but you guys don't have a record of the RMA# that was given to Johnstone. Probably written down wrong on the receipt that they gave me....
  2. Replies
    29
    Views
    2,692

    Nice...Very Nice!

    Nice...Very Nice!
  3. Replies
    81
    Views
    9,390

    What is the normal turn-around time for warranty...

    What is the normal turn-around time for warranty service? I sent mine back (through Johnstone) on Monday the 10th.
  4. Replies
    6
    Views
    606

    I bought an SMAN 3 two months ago. Broke a clamp...

    I bought an SMAN 3 two months ago. Broke a clamp a week after I got it and Johnstone swapped it out for me right away. About a week ago, my low side gauge got stuck at 136.2 PSI and would not budge...
  5. Replies
    2
    Views
    1,028

    I sent them my resume several years back and was...

    I sent them my resume several years back and was contacted by an agent in a few days. No chiller work, but she thought I would be a good "fit" for an ice plant they were building. The work weeks are...
  6. Replies
    10
    Views
    590

    I guess I just assumed based on the name of the...

    I guess I just assumed based on the name of the forum.

    So I guess my question would be: WTF would he be doing here if he's not in the field.

    'Scuse me while I head over to DIYneurosurgery.com...
  7. Replies
    10
    Views
    590

    Come on...if you can't figure out how to DIY...

    Come on...if you can't figure out how to DIY install a friggin garbage disposal, what kind of an A/C man are you?

    Home Depot even gives free classes for muggles.
  8. Thread: RTAA

    by ChillerWisperer
    Replies
    7
    Views
    810

    Bingo...I'll bet the female load solenoid coil is...

    Bingo...I'll bet the female load solenoid coil is burnt. It's the one by itself on the side of the compressor. It should energize about a minute after the compressor starts for the first stage of...
  9. Replies
    12
    Views
    11,018

    Quit yelling, open the yellow pages and contact a...

    Quit yelling, open the yellow pages and contact a professional tech.

    That's how you do it.
  10. Replies
    19
    Views
    1,422

    http://www.scubaboard.com/forums/images/smilies/ro...

    http://www.scubaboard.com/forums/images/smilies/rofl3.gif
  11. Should have had a pro do it. This ain't a toy!...

    Should have had a pro do it. This ain't a toy! Though your first two mistakes were interviewing a guy who said he was a chiller mechanic, then compounding the problem by not knowing the difference...
  12. Replies
    6
    Views
    1,861

    Hey thanks, Heavy. I'm trying to track down some...

    Hey thanks, Heavy. I'm trying to track down some bleed resistors for a YK speed drive. I have the 800 number, but not the website. Most appreciated!
  13. Replies
    5
    Views
    2,011

    Not asking for much are you?:eek2:

    Not asking for much are you?:eek2:
  14. Replies
    19
    Views
    3,163

    This thread is over 5 years old! I think tiny...

    This thread is over 5 years old! I think tiny probably found another line of work by now.
  15. Replies
    6
    Views
    775

    D'oh!

    D'oh!
  16. Replies
    0
    Views
    1,154

    FS: Trane 5 ton XR14 condensing unit

    I have a Trane 5 ton XR14 R-22 condensing unit that was pulled out when the customer upgraded to a 410 unit. Mfr date is 11/05, so warranty is good through 11/10. Compressor was shot, so I got a...
  17. Replies
    6
    Views
    775

    That composite material is the plastic (carbon...

    That composite material is the plastic (carbon fiber actually) from the gate rotor lining. Do yourself a favor and pull an inspection cover. I think you just wasted time pulling the charge. You could...
  18. Replies
    6
    Views
    775

    Isolate the compressor and pull a side cover to...

    Isolate the compressor and pull a side cover to inspect the gate rotors. They need to be smooth and with a knifelike edge. If they are pitted, scored or gouged they won't seal well enough to get...
  19. Replies
    4
    Views
    1,377

    Same download, but Trane techs have the Kestral...

    Same download, but Trane techs have the Kestral key to unlock Kestral view. Yes, you can use the garden variety version to bind a new device like a quad relay output board or other LLID device. You...
  20. Replies
    39
    Views
    4,026

    Jesus...what is this? The Bevis and Butthead...

    Jesus...what is this? The Bevis and Butthead show?!?

    Read the damn book when you're not sure!

    We give you tools and you still beat on it with hammers. /End rant/

    cri: not ragging on you,...
  21. Replies
    39
    Views
    4,026

    These may help. I've included the unReliatel...

    These may help. I've included the unReliatel version too, since I'm sure you'll run into them a bit.

    Complements of Mother Trane...
  22. Deciphering Trane small compressor model numbers

    I need help deciphering model numbers on small Trane compressors. A friend called me because I'm supposed to be the "Trane guy" and asked about model numbers. He has a GP343FG1GA and wants to replace...
  23. It's a last ditch effort to get a unit through a...

    It's a last ditch effort to get a unit through a summer or until coils can be replaced. It definitely speeds electrolytic corrosion and the days of the coil are numbered once you've decided to take...
  24. Replies
    19
    Views
    2,854

    Like graham said, install your transducer as far...

    Like graham said, install your transducer as far away from the vacuum pump as possible. Use a double female flare coupling and tighten it down good. If I'm still pulling in air around the coupling,...
  25. Replies
    31
    Views
    2,999

    Dehydration is your single biggest enemy. If you...

    Dehydration is your single biggest enemy. If you start to get dehydrated, your cooling mechanism isn't as efficient and your electrolytes go out of whack which affects your thought process. Remember...