  1. Replies
    31
    Views
    23,169

    i know

    I am one of their biggest cheerleaders. We have 4 guys that we sent to cali for factory training and most problems we run into were ther contractors install mistakes. have had maybe to oder two...
  2. Replies
    31
    Views
    23,169

    lets be clear

    Mitsu cant touch the heating capacity of Daikin especially in low temps. The a/c will run lower than the posted lockout temps also. Daikin is also the originator not the imitator. They are #2 in the...
  3. Replies
    10
    Views
    529

    best out there

    testo 330-1
  4. Replies
    14
    Views
    1,050

    looking for the best

    go to the originator not the imitators use Daikin mini splits and vrv systems less than a tenth of one percent global failure rate.
  5. Replies
    10
    Views
    491

    rethink overpaid

    I once thought these guys were overpaid until I had the chance to try and hit a 100 mph fast ball and a 78 mph curve ball. this takes unbelivable skill and talent.
  6. Replies
    0
    Views
    231

    lets talk baseball and bat discounts

    Ok, lets forget about heating for a moment. How many dads here have kids in baseball or softball? how many coach? how many cant due to on call schedules and work in general? Here is a freebie for you...
  7. Replies
    13
    Views
    1,368

    let me explain "good techs are a dying breed" to...

    let me explain "good techs are a dying breed"
    to many want to graduate and get a office job to few want to get their hands dirty.
  8. Replies
    13
    Views
    1,368

    22 yrs in the trade. learned from school of hard...

    22 yrs in the trade. learned from school of hard knocks and some of the best in the biz, now service manager for small 6 mllion dollar company. here is my advise keep your nose clean. respect all...
  9. Replies
    28
    Views
    1,611

    checked this?

    are you using new gauges? allot of my guys have got new gauges that leaked. pressure test and soap your hoses.
  10. Replies
    18
    Views
    1,673

    rheem has some nice rooftops trane and lennox...

    rheem has some nice rooftops trane and lennox would be my next choices
  11. Replies
    26
    Views
    13,746

    I heard the turbo cors are very sensitive to...

    I heard the turbo cors are very sensitive to vibration and must be isolated. this makes cents due to the electronics in them. We haven't used one yet but I'm dying to. with all of the energy concern...
  12. Replies
    8
    Views
    1,414

    this is a non propriatary controller. from my...

    this is a non propriatary controller. from my info jci propriatary cannot get this control. It is a web based controller you will need the IP address TO GET INTO IT I know very little else about it...
  13. Thread: Jackson & Church

    by glgto
    Replies
    4
    Views
    956

    I didn't know they still made rooftops. They are...

    I didn't know they still made rooftops. They are made here in York,PA a company named AYSIS or something bought them they have a web site search jackson and church. Make sure the blower wheel and...
  14. Replies
    10
    Views
    1,047

    I was told by my Johnson rep. that you must have...

    I was told by my Johnson rep. that you must have a serial port. usb adapter will not work.modern technoligy huh?
  15. Replies
    13
    Views
    4,568

    don't know what board you have but if it has...

    don't know what board you have but if it has several ice cube style relays on it the older york's were notorious for the solder joints cracking pull the board off the mounts after you lock out the...
  16. Replies
    4
    Views
    1,092

    I agree that or remove the coil and clean...

    I agree that or remove the coil and clean thoughly and reinstall. sorry you probable won't like that answer either
  17. Thread: Pipe thread

    by glgto
    Replies
    5
    Views
    1,153

    Do not use teflon or dope! use a good quality rtv...

    Do not use teflon or dope! use a good quality rtv silicone we have had problems in the past with our guys and teflon if you put to much on you can crack or distort the fitting causing a leak. the...
  18. Replies
    98
    Views
    10,284

    unanswered questions from john

    ok, airplanes and race cars use nitrogen because it is dry if you were to use a air compressor the air would contain moisture that moisture will expand when heated as in landing and racing. same...
  19. Replies
    10
    Views
    2,011

    you are screwed well not really the fine people...

    you are screwed well not really the fine people at york overlooked this in there board . ive had the same trouble and i call a friend who just happens to be the service manager at york international...
  20. WE ARE IN PA AND GROUND SOURCE IS GETTING PRETTY...

    WE ARE IN PA AND GROUND SOURCE IS GETTING PRETTY POPULAR IN COMMERCIAL APPLICATIONS WE JUST FINISHED A RETIREMENT COMPLEX THAT WAS ALL GROUND SOURCE . ALTHOUGH UPFRONT COST ARE HIGH PEOPLE ARE FIALLY...
  21. Replies
    98
    Views
    10,284

    250 microns standard? maybe on a new unit that...

    250 microns standard? maybe on a new unit that has had no refrigerant in it or a small system.most compressor manufactures only recommend vacuum below 1000 microns!we shoot for 500. its very tough to...
  22. Replies
    2
    Views
    1,787

    rheem tracks all units buy serial number if you...

    rheem tracks all units buy serial number if you have that they may be able to help you
  23. Replies
    24
    Views
    2,398

    you know freezone is expensive and only gonna get...

    you know freezone is expensive and only gonna get worse and after you use up the 30 gallons the drum is hard to get rid of with epa hazmat etc. i think i would replace the unit with the upgraded...
  24. Replies
    4
    Views
    1,489

    depends on experience fax# 717-792-6608 e-mail...

    depends on experience fax# 717-792-6608 e-mail gregl@spanglerboyer.com
  25. Replies
    6
    Views
    1,253

    say what?

    31 deg is way to high i agree. make sure when getting temps that you are insulated and tight ive seen alot of guys take temps at condensers with clamp on style thermocouples and the condenser air...