Search:
Type: Posts; User: ezone
Search: Search took 0.00 seconds.
-
07-07-2011, 06:12 PM
- Replies
- 11
- Views
- 3,556
double chech rotatation wrong direction will...
double chech rotatation wrong direction will cause higher amp draw. I know, been there done it
-
10-02-2010, 10:00 PM
Thread: Anyone know anything about Soda Dispensers
by ezone- Replies
- 19
- Views
- 1,820
Primmer don t know where you're located. Internet...
Primmer don t know where you're located. Internet search for beverage tubing or parts should get you going. Oeiter clamps can be found at same or Graingers Supply.
Distance from cold plate or... -
10-01-2010, 01:14 AM
Thread: Anyone know anything about Soda Dispensers
by ezone- Replies
- 19
- Views
- 1,820
:gah:Primmers this is a project if its your...
:gah:Primmers this is a project if its your first install. Do you have acess to beverage parts? You're going to need about 200ft. of tubing (number of buttons on gun plus 2), Stainless steel...
-
08-08-2010, 03:37 PM
Thread: Condensation from open display case
by ezone- Replies
- 7
- Views
- 666
Pez toy..can't begin to tell you how many open...
Pez toy..can't begin to tell you how many open display cases, with refrigeration problems have been fixed by putting shelfs in correct order. Small at top larger at bottom. I'm seeing them more and...
-
02-19-2009, 07:54 PM
Thread: Help!! Trane Voyager Experts
by ezone- Replies
- 22
- Views
- 3,135
Toptech you're the man thanks. Lost pages on a...
Toptech you're the man thanks. Lost pages on a rainy day begruge buying another manual procrastination works. ez
-
10-08-2008, 08:26 PM
- Replies
- 33
- Views
- 1,693
one quick note on the freezer. A 25x25 is pretty...
one quick note on the freezer. A 25x25 is pretty large box. Assuming its a concrete floor with insullation underneath. I'd pull it down slow, allowing walls, floors etc. to reach temp 5 to 10 degrees...
-
06-12-2008, 07:32 PM
Thread: Hoshizaki Board Repair
by ezone- Replies
- 10
- Views
- 847
baub excellent job on the video, better than...
baub excellent job on the video, better than some pro training I've seen. Precise, clear and clean,
-
04-23-2008, 10:43 PM
Thread: Trane Guys???
by ezone- Replies
- 6
- Views
- 676
cg2 is right. there is a bulletin avail. certain...
cg2 is right. there is a bulletin avail. certain seris has bad motors. I've changed out two this winter. Found #3 today on a ac start up. Getting Trane to admit it is pretty hard though. First one...
-
A couple of points about co2 There's two types...
A couple of points about co2
There's two types of tanks as stated b4 one has a siphon tube and will pull liquid the other doesn't and will pull gas.
Never use a tank from a beverage company. They... -
04-15-2008, 08:47 PM
Thread: W/I Clr Retro Guru's needed
by ezone- Replies
- 13
- Views
- 787
Sounds like you finally got it dried out, and...
Sounds like you finally got it dried out, and cleaned out. That was a lot of moisture. The end result of a bunch of top offs. Not finding the low side leak and just adding gas,gas gas. Those kind of...
-
04-15-2008, 08:11 PM
Thread: Carbonator?????
by ezone- Replies
- 15
- Views
- 3,272
Here's a couple more tidbits There's also a...
Here's a couple more tidbits
There's also a single check valve on co2 line to prevent seltzer from backing up into co2 tank. When tank pressure drops below carbonator pressure.
Inside of tank... -
01-28-2008, 10:00 PM
Thread: Restoration of Soda Fountain
by ezone- Replies
- 9
- Views
- 1,315
ok if this is what I think it is you have an old...
ok if this is what I think it is you have an old fountain system in the order of a B and B i.e. a bastian and blessing. see if you can reference anything with that name. The copper line is water in....
-
01-08-2008, 07:37 PM
Thread: Prep table
by ezone- Replies
- 14
- Views
- 1,340
This thread is the reason why I like this forum....
This thread is the reason why I like this forum. Good and timely info. I've been doing this work for too long, and never seen a prep with a epr. One less surprise waiting for me. I'm not fond of...
-
10-21-2007, 02:15 AM
Thread: Frymaster Problem
by ezone- Replies
- 32
- Views
- 5,356
Two things happened when I read this thread ...
Two things happened when I read this thread First I thought good initiative from a new tech and then all the little hairs on the back of my neck went up.
1 Call frymaster First b4 you do... -
10-21-2007, 01:35 AM
Thread: question about a drink machine
by ezone- Replies
- 20
- Views
- 1,431
ok here's what you can do. open door, unplug coin...
ok here's what you can do. open door, unplug coin mech ( large black plug ). then lift mech up off of slotted screw mounts. looking at top of mech you'll see 2 levers. one on each side lift up pull...
-
08-20-2007, 10:01 PM
Thread: 3wire rev rot. evap motors
by ezone- Replies
- 11
- Views
- 787
Joe seen them in markets small True pop cases....
Joe seen them in markets small True pop cases. They use a residential defrost timer to reverse fan. Belive me it doesen't work. coil still blocks up might take a little longer ...
-
08-09-2007, 09:32 PM
Thread: beer draft lines
by ezone- Replies
- 12
- Views
- 1,102
DOW seem to remember a sales rep going on about...
DOW seem to remember a sales rep going on about clarity of product at too low of temp. tends to get cloudy as I didn't have a good thermometer and was forced to use the taste temp method the...
-
08-09-2007, 08:42 PM
Thread: beer draft lines
by ezone- Replies
- 12
- Views
- 1,102
sounds like you have a lopped evap. yes txv and...
sounds like you have a lopped evap. yes txv and epr set pressure control for an evap temp of 28 use pt chart per refrigerant. watch lite beer, first to freeze. check all insulation. Remember a 3 to...
-
04-29-2007, 10:54 PM
Thread: coke machine
by ezone- Replies
- 31
- Views
- 2,189
ha !!! I know what you're doinn. 'cause I'm an...
ha !!! I know what you're doinn. 'cause I'm an old timer too.
-
a slurpee unit besides being expensive, really...
a slurpee unit besides being expensive, really expensive, is labor intensive. I'd look on e bay, or someplace like that for a bunn, or ouligani(spelling sucks)counter top unit like you see in c...
-
03-25-2007, 11:10 PM
Thread: Man killed nj when compressor explodes
by ezone- Replies
- 10
- Views
- 1,204
fireye03 is right got same story from supply...
fireye03 is right got same story from supply house. unregulated nitro tank. don't know what possed him to even think of doing it. he didn't sound like a rookie. 37 yrs. old 2 kids shame. this is a...
-
03-04-2007, 07:46 PM
Thread: I hate it when that happens
by ezone- Replies
- 19
- Views
- 1,265
after all that you now have to plug the condenser...
after all that you now have to plug the condenser back into the spider I carry a couple of short {24") AC extension cords. Pick them up at hardware store. Saves needing exta elbow.
-
03-04-2007, 07:25 PM
Thread: You Won't Fit In There!!! She told me...
by ezone- Replies
- 7
- Views
- 1,544
yo r12 welcome to soda. sounds like you ended up...
yo r12 welcome to soda. sounds like you ended up looking like a punk rocker. Orange spiked hair and all. A sugesstion Refer supply houses carry vise grip pinch off pliers. Try them they have...
-
02-24-2007, 05:16 PM
Thread: You Won't Fit In There!!! She told me...
by ezone- Replies
- 7
- Views
- 1,544
yo r12, funny, moreso 'cause been there done...
yo r12, funny, moreso 'cause been there done that. If it was a 7/11 how'd you get your feet to move in the goo? Don't know why you had to bribe a kid, been my experience they'll do anything to get a...
-
02-18-2007, 07:37 PM
Thread: Cap Tube chaser
by ezone- Replies
- 29
- Views
- 1,995
also agree with Mikey poe + 134 + heat= clogged...
also agree with Mikey poe + 134 + heat= clogged cap. do't know what model you're working on but most of their reach ins are acessable from top a couple of screws and you can pull the evap up and work...
Results 1 to 25 of 38