  1. Thread: MNB- 1000

    by grovecreek
    Replies
    2
    Views
    169

    MNB- 1000

    What tool could a person use to figure out the points in the controller are and what is writeable or not ? Tac Vista
  2. Replies
    2
    Views
    266

    I tried to open it with no luck ? Thanks

    I tried to open it with no luck ? Thanks
  3. Replies
    2
    Views
    266

    Ax Switcher 2

    Are there available download for this tool ? They work very well !
  4. Replies
    2
    Views
    404

    I did find some information at our office through...

    I did find some information at our office through some very old records. It looks like it goes back to around 1996.
  5. Replies
    2
    Views
    404

    Alerton 450-st Controller

    I am looking for a good owners manual or specification sheet on this controller ? I can find info on the tux 450 but nothing on the ST model.
  6. Replies
    1
    Views
    527

    Bacnet point list for York RTU

    I have a York RTU YPAL055NVC46BBAX
    Serial RNKM002087

    Looking for the Bacnet points list for this unit ?
  7. Replies
    9
    Views
    3,801

    Bacnet Points on like a RTU how do you pull up...

    Bacnet Points on like a RTU how do you pull up those points to look at them ? Is there a way through device manager ?
  8. Replies
    6
    Views
    569

    If you could send those Docs that would be great !

    If you could send those Docs that would be great !
  9. Replies
    6
    Views
    569

    If you could send those Docs that would be great !

    If you could send those Docs that would be great !
  10. Replies
    6
    Views
    569

    There we go all setup.

    There we go all setup.
  11. Replies
    6
    Views
    569

    Carrier Pilot

    I have to hook up controls to a new VAV box and configure it to the existing Pilot. I am looking for some good manuals to be able to set this up ? The zone controller will be a VVT. Thanks
  12. Replies
    12
    Views
    1,228

    It is Envision I did get it to work today. Your...

    It is Envision I did get it to work today. Your IP address for your computer and Envision need to be the same and the field service tool needs to be one number off. So with Compass it is a lot...
  13. Replies
    12
    Views
    1,228

    BASRTP-B Portable Router Alerton

    Trying to get this router to work on my laptop. Does anybody know what all the settings are suppose to be for the configuration ? On my job I have the Enable Bacnet Protocol checked.
  14. Replies
    1
    Views
    465

    So I went into Zones advanced area and changed...

    So I went into Zones advanced area and changed the priority array 13 to 12 and this took care of the problem. Something is writing to that priority on 13 but could not find where. Working good now.
  15. Replies
    1
    Views
    465

    Alerton Schedules

    I have one Heat Pump where the schedule keeps going unoccupied on the zone. All the other Heat Pumps on the same Global zone work fine ?
  16. Thread: DDC Toolbar

    by grovecreek
    Replies
    0
    Views
    562

    DDC Toolbar

    Working with DDC toolbar and was wondering if you can update your point data offline using your laptop offline away from the job ? I am just trying to make changes on the existing visio file on my...
  17. Thread: Alerton

    by grovecreek
    Replies
    0
    Views
    416

    Alerton

    Does anybody have any programming code to slave 3 out of 4 vav's. Most of it would be transfers in the global code.
  18. Thread: Alerton VLC

    by grovecreek
    Replies
    2
    Views
    1,288

    Yes I could try that tomorrow.

    Yes I could try that tomorrow.
  19. Thread: Alerton VLC

    by grovecreek
    Replies
    2
    Views
    1,288

    Alerton VLC

    Controller VLC SD2A has solid green light on led. It should have a 3 flash instead. I checked MAC address and has correct address on dip switches but still stays a solid green lights. This device is...
  20. Replies
    3
    Views
    1,200

    The global code for this bcm should be 112000 but...

    The global code for this bcm should be 112000 but it is no where to be found.
  21. Replies
    3
    Views
    1,200

    Alerton Envision

    Building I am working in network number for these devices are 112 but i cannot find global code with these numbers at all. I went through all the ddc code and found nothing. Is there a way to find...
  22. Replies
    4
    Views
    1,417

    Thanks guys it was the IP address conflict that...

    Thanks guys it was the IP address conflict that was causing the issue. Working good now.
  23. Replies
    4
    Views
    1,417

    BASRTP-B BACnet router

    My laptop I use with this device has been working fine until lately. I need to go into the settings to change my network number but i cannot get the router config page to open. I have windows 7 does...
  24. Thread: Visiologic

    by grovecreek
    Replies
    3
    Views
    1,367

    Yes thank you for the advice. I was looking at...

    Yes thank you for the advice. I was looking at alerton standard bitmaps and prog and was trying to find some smaller code to go over and work with.
  25. Thread: Visiologic

    by grovecreek
    Replies
    3
    Views
    1,367

    Visiologic

    What is the way to learn how to write code in visio. Are there any good books or online training Thanks
  26. Replies
    5
    Views
    954

    Yes I agree just wondering if anyone has had...

    Yes I agree just wondering if anyone has had issues with this model controller flame rod and grounding are good.
  27. Replies
    5
    Views
    954

    Flame sense problem

    Our Church has two Weil Mclain boilers model number is cp3513605 I cannot get micro amp reading any higher than about .80 amps. We ran new ground wire back to control panel and still nothing. I...
  28. Replies
    1
    Views
    708

    Samsung mini split

    This system is about 5 years old, I don't have the model or serial number at this time. It is a cooling only with two power heads, in the past I had freon leaks every season but not this year. This...
  29. Replies
    8
    Views
    950

    There is glycol in the system now but I will have...

    There is glycol in the system now but I will have to test to see where I am at now.
  30. Replies
    8
    Views
    950

    Thanks for the advise.

    Thanks for the advise.
  31. Replies
    8
    Views
    950

    I work on rtu most of the time can you give me...

    I work on rtu most of the time can you give me some advise.
  32. Replies
    8
    Views
    950

    Boiler Questions

    I have not worked on a comercial boiler in quite a while. Today at my church I was trying to replace the low water cut off. There was no room to work on this it was very hard to get union nuts loose....
  33. Replies
    19
    Views
    4,954

    Today I installed my first True steam humidifier....

    Today I installed my first True steam humidifier. The controls were true IAQ setup every time I seem to install these the outdoor sensor it is always reading way off on temp. The sensor was all the...
  34. Replies
    19
    Views
    4,954

    The furnace is in a closet space that is...

    The furnace is in a closet space that is insulated up in the attic area. So we don't have to worry about freezing in that area.
  35. Replies
    19
    Views
    4,954

    This installtion is up in a attic space with no...

    This installtion is up in a attic space with no floor drain to work with. Just a condo pump to discharge the water. That is what concerns me is the hot water when it discharges into pump.
  36. Replies
    19
    Views
    4,954

    I just want to make sure the condensate pump can...

    I just want to make sure the condensate pump can handle the temp of the water and discharge amount.
  37. Replies
    19
    Views
    4,954

    True Steam Humidifier

    Does anybody know if the 6 gal true steam Honeywell humidifier can discharge water into a condo pump? It sounds like they discharge quite a bit of water at one time. Thanks Grove
  38. Replies
    1
    Views
    641

    co test spray

    Does anybody no where a person can purchase some test spray in a can.?Aprilaire does not carry this product no longer.
  39. Replies
    4
    Views
    866

    Have you ran into this befor?

    Have you ran into this befor?
  40. Replies
    4
    Views
    866

    I did speak with a HW rep today either the t-stat...

    I did speak with a HW rep today either the t-stat is acting up or setting on stat is set on option 2 or 0 on the parameter number 370. I will check when I go back to the customers house.
  41. Replies
    4
    Views
    866

    new networking zone system Honeywell

    I was finishing up at the house today and all of a sudden the t-stat showed error 54. All of a sudden the humidity reading went away and caused this code. Outdoor sensor is installed for this...
  42. Thread: Roto locks

    by grovecreek
    Replies
    6
    Views
    1,135

    Yes it is leaking at brazed joint. So no silfos...

    Yes it is leaking at brazed joint. So no silfos just solder the joint in?
  43. Thread: Roto locks

    by grovecreek
    Replies
    6
    Views
    1,135

    Thanks I will order a new roto lock and check it...

    Thanks I will order a new roto lock and check it over. I have never run into this befor.
  44. Thread: Roto locks

    by grovecreek
    Replies
    6
    Views
    1,135

    Roto locks

    The other day on a service call I located a leak on the suction side roto lock at the comp. Today I tryed a new seal but there is still a leak on the fitting that is mounted on the copper pipe. Are...
  45. Replies
    2
    Views
    1,671

    Inducer limit open

    Trane tuy080r9v furnace what would cause this to open? Furnace not properly venting and overheating?
  46. Replies
    15
    Views
    2,774

    Evirazone Iaq

    Just wondering if anybody has had trouble with the outdoor sensor reading correctly and the humidifier control on t-stat to turn it on? I have installed quite a few of these systems and there is...
  47. Replies
    6
    Views
    973

    It is hard to get any true readings because on...

    It is hard to get any true readings because on start up or shut down is the only time it makes the noise. The liquid line near the evap is really pulsating inside during the time it is making the...
  48. Replies
    6
    Views
    973

    I have the same thing going on at a customers...

    I have the same thing going on at a customers house. I pumped the system down and checked the fixed orifice metering divice and found nothing. I have to believe something is resticted inside the evap...
  49. Thread: GPS

    by grovecreek
    Replies
    25
    Views
    2,472

    Just wondering how it is when you are being...

    Just wondering how it is when you are being tracked where ever you go. All the vans at our shop are having them installed this week. Just curious how it goes with everybody else out there driving a...
  50. Replies
    18
    Views
    2,293

    I did talk with tech support today,I need to look...

    I did talk with tech support today,I need to look at the ID sticker inside and go through the dip switch set up for the cooling speed. I may have it set to high the directions are so different than a...