Trane Comm 4
What exactly is the Trane comm 4 protocol...RS-485? Is there an extender or repeater for this comm link that anyone's used successfully. I see various RS-485 repeaters by different vendors. I don't...
-
01-24-2008, 11:27 AM
Thread: Trane Series R Chillers
by zigmund- Replies
- 25
- Views
- 1,532
You are right and that in essence is the source...
You are right and that in essence is the source of the problem. The slide will not respond when it needs to.To current limit, evap conditions, etc. At least thats what the guys at Pueblo are telling...
-
01-24-2008, 02:44 AM
Thread: Trane Series R Chillers
by zigmund- Replies
- 25
- Views
- 1,532
Flows are solid at 1100 to 1200 gpm, condenser...
Flows are solid at 1100 to 1200 gpm, condenser water constant at 78 deg. I'm working with Trane Pueblo presently. Thay are aware of the problem and have been working on a revised control program to...
-
01-23-2008, 12:55 AM
Thread: Trane Series R Chillers
by zigmund- Replies
- 25
- Views
- 1,532
usually, but sometimes later.
usually, but sometimes later.
-
01-23-2008, 12:53 AM
Thread: Trane Series R Chillers
by zigmund- Replies
- 25
- Views
- 1,532
which trip points specifically?
which trip points specifically?
-
01-23-2008, 12:52 AM
Thread: Trane Series R Chillers
by zigmund- Replies
- 25
- Views
- 1,532
Some additional info. 26% glycol, evap pressure...
Some additional info. 26% glycol, evap pressure 20 psi, evap approach 2.8 deg, evap flow 1100 gpm.
-
01-22-2008, 02:10 AM
Thread: Trane Series R Chillers
by zigmund- Replies
- 25
- Views
- 1,532
These units are brand new installed in August ,...
These units are brand new installed in August , put into operation in Sept.
-
01-22-2008, 02:08 AM
Thread: Trane Series R Chillers
by zigmund- Replies
- 25
- Views
- 1,532
All 3 units run in ice mode. For conventional...
All 3 units run in ice mode. For conventional mode the units are equipped with both evaporator and condenser isolation valves.
-
01-22-2008, 02:06 AM
Thread: Trane Series R Chillers
by zigmund- Replies
- 25
- Views
- 1,532
These are RTHD's. Now Running condenser at 75...
These are RTHD's. Now Running condenser at 75 deg. Let me take a look at these other items in your post and I'll get back to you.
-
01-21-2008, 01:36 AM
Thread: Trane Series R Chillers
by zigmund- Replies
- 25
- Views
- 1,532
Will do. Will post more info after tomorrow....
Will do. Will post more info after tomorrow. Thanks for the help!
-
01-21-2008, 12:45 AM
Thread: Trane Series R Chillers
by zigmund- Replies
- 25
- Views
- 1,532
Oh, by the way this job is in Honolulu. The trips...
Oh, by the way this job is in Honolulu. The trips happen well into the operating period usually.
-
01-21-2008, 12:41 AM
Thread: Trane Series R Chillers
by zigmund- Replies
- 25
- Views
- 1,532
I start tomorrow, but one thing I do know is that...
I start tomorrow, but one thing I do know is that they let the condenser water temp drift down with the ambient outside temp plus cooling tower at night when in ice making mode. This results in cond...
-
01-20-2008, 11:16 PM
Thread: Trane Series R Chillers
by zigmund- Replies
- 25
- Views
- 1,532
Trane Series R Chillers
Am about to begin investigating chronic low evaporator pressure trips in 3 Trane Series R's (parallel) used for Calmac Ice Storage system. All 3 trip intermittently. Any ideas anyone. Possible...
-
01-02-2008, 01:11 PM
Thread: Trane Varitrac System
by zigmund- Replies
- 8
- Views
- 1,476
Varitrac CCP
The printer port wont work.Its has to be a serial port. I've also used a usb to serial converter. Then you have to match the correct Baud rate usually 1200. Trial and error will usually find it. I...
-
12-31-2007, 06:08 PM
Thread: Need Lonworks I/O device
by zigmund- Replies
- 8
- Views
- 801
Lonworks I/O device
The Trane Mp580/581 would be a huge expense for only 6 binary outputs and still very large even in the frame mount version. I might as well go back to Trane TCM's.
-
12-31-2007, 05:26 PM
Thread: Need Lonworks I/O device
by zigmund- Replies
- 8
- Views
- 801
Lonworks I/O device
I guess it would be an open solution as it would be part of a Tracer Summit system on their comm 5 network(lontalk). The lighting contactors I'm controlling usually number 12 to 36 per group. The...
-
12-31-2007, 02:21 PM
Thread: Need Lonworks I/O device
by zigmund- Replies
- 8
- Views
- 801
I did check there. A lot of good stuff but not...
I did check there. A lot of good stuff but not exactly what I'm after. I need high density binary outputs in a small package for lighting control. Maintained contacts or triacs driving IDEC pilot...
-
12-30-2007, 08:06 PM
Thread: Need Lonworks I/O device
by zigmund- Replies
- 8
- Views
- 801
Need Lonworks I/O device
I'm looking for a Lonworks I/O device to use with Tracer Summit. I need something thats 24vac powered with as many binary outputs as possible(relay or triac). The smaller the size the better. A few...
Results 1 to 18 of 20