  1. Replies
    18
    Views
    2,645

    keep us posted on the progress, i like it.....do...

    keep us posted on the progress, i like it.....do you have a SEER rating for it yet??
    a 3.5 ton is around a 78 orifice , and a 4 ton an 82 . don't know if that is of any help to you though.
  2. Replies
    7
    Views
    675

    most likely not the AH , but the condenser...

    most likely not the AH , but the condenser compressor start up. a 3.5 is usually 10-2 wire , where a 4 ton requires #8 AWG. something you can do as a Homeowner , is go to the unit outside and look at...
  3. Replies
    11
    Views
    1,100

    LOL....good one watercop. i assume he wants to...

    LOL....good one watercop.
    i assume he wants to make sure each register in the house is distributing equally. Affordable tool, ...is there such a thing???
  4. Replies
    7
    Views
    794

    THX for the replies guys. like i said , i got...

    THX for the replies guys. like i said , i got GRILLES....LOL
    plenty of filter area. so is the cut out good to go ??or do i need to add another return?
  5. Replies
    2
    Views
    675

    any one else?????

    any one else?????
  6. Replies
    7
    Views
    794

    how many square inches should i have for a 3.5...

    how many square inches should i have for a 3.5 ton heat pump.
    I have 2 grills on same wall(corner), one is 20x20 the other 16x20, but they share the same box(metal) , as it goes into through the...
  7. Replies
    2
    Views
    675

    not looking for how too , just diagnosis Ruud...

    not looking for how too , just diagnosis
    Ruud UPBK 042JA2 H.P.with matching Rheem AH 4 ton coil but the jet c/o for the 3.5, all metal ductwork , clean coil and filters

    using the chart on...
  8. Replies
    3
    Views
    717

    you can ask for a heavy duty contactor (silver...

    you can ask for a heavy duty contactor (silver contacts)
  9. Replies
    0
    Views
    395

    i bought a roll of that HIGH DOLLAR foil bubble...

    i bought a roll of that HIGH DOLLAR foil bubble wrap (200.00). don't get me wrong , i like it , but how much better is it than the fiberglass duct wrap???
    I have metal trunk line with the insulation...
  10. Replies
    27
    Views
    2,203

    being able to ask AND get everything you've...

    being able to ask AND get everything you've listed , but the price doesn't change at the end.......yep , that's good
  11. Replies
    4
    Views
    990

    metal cost an extra GRAND easy if you count trunk...

    metal cost an extra GRAND easy if you count trunk line as well. pay the hundred.....
  12. Replies
    15
    Views
    1,246

    sounds like you may have a leak...

    sounds like you may have a leak...
  13. Replies
    9
    Views
    900

    how old is the new coil??

    how old is the new coil??
  14. Replies
    5
    Views
    612

    sounds like the only thing you haven't changed is...

    sounds like the only thing you haven't changed is the low-voltage wire .....HHmmmmm
  15. Thread: 250v

    by toddgotfish
    Replies
    11
    Views
    815

    Higher Voltage = Higher Current Draw not less

    Higher Voltage = Higher Current Draw not less
  16. they make booster fans for each individual line....

    they make booster fans for each individual line. you may want to find out the supply duct size heading upstairs first though.
  17. Replies
    10
    Views
    919

    no , its in the air handler. but its not an...

    no , its in the air handler. but its not an expensive repair and they keep them on their truck. if its only 3 yrs old , there may be a fuse in the A/H. either way , should be a quick fix ..
  18. Replies
    10
    Views
    919

    sounds like you may have accidently shorted the...

    sounds like you may have accidently shorted the transformer with the new thermostat. there would be nothing to trip on the low voltage side . i'd go ahead and get someone out in the morning to look...
  19. Replies
    9
    Views
    1,299

    sorry , this may help ......RBHC-21J14SFC W/ 14...

    sorry , this may help ......RBHC-21J14SFC
    W/ 14 KW heat strips ....and the coil is RCBA-4882G....SER. M3105......, as stated this unit is brand spankin new , its paid for, but the entire system...
  20. Replies
    10
    Views
    919

    you need to check the voltage on the 24 volt...

    you need to check the voltage on the 24 volt side. chances are , its gone.
  21. Replies
    9
    Views
    1,299

    thanks for the replies , there is only one Rheem...

    thanks for the replies , there is only one Rheem dealer in the area , i guess i'm gonna be at his mercy. i did call the Rheem supply house and they said the coil was good for 3-1/2 to 4 ton outdoor...
  22. Replies
    9
    Views
    1,299

    i'm having a new system installed in my home that...

    i'm having a new system installed in my home that i Don't live in yet(fixer upper). i have a Rheem 4 ton air handler . i'm getting prices on a heat pump installed on the other end. One of the...
  23. Replies
    2
    Views
    634

    was wiring a generator the other day in a huge...

    was wiring a generator the other day in a huge house , and noticed the HVAC guy unrolling some HUGE copper, said it was 1-1/8" , i asked what was that for , a 10 ton unit , he said no, you need this...