Search:

Type: Posts; User: jeremyjp

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Unbelievable!!!! That is a disgrace to our trade....

    Unbelievable!!!! That is a disgrace to our trade. Must be the work of the un-licensed people who under-bid "us" licensed contractors who are just trying to stay alive as a business.
  2. Replies
    225
    Views
    45,874

    Sticky: Poll: I Voted!!!!

    I Voted!!!!
  3. Replies
    23
    Views
    1,424

    Nice descriptive writing skills!!! was able to...

    Nice descriptive writing skills!!! was able to follow the whole way :)
  4. R-408A question(Evap temp) for low temp box

    For other Refer guys. Low Temp. Using R-408A, on a low temp box, what is the typical operation suction line temp/pressure?? at the evaporator? 24psi(-10) or 33psi(5 degrees)???:putergreet:
  5. Replies
    12
    Views
    5,140

    But... i guess i'm just a Bryant/Carrier fan, and...

    But... i guess i'm just a Bryant/Carrier fan, and when it comes to repairs, they are simple to diagnois and i can actually have room in the cabinet to do any repairs.
  6. Replies
    14
    Views
    621

    This subdivision was built within the last 5 yrs....

    This subdivision was built within the last 5 yrs. Kinda in a remote area and houses are nice and custom too. They just got the shaft cause no Nat gas ran to them. Rumored that bills are outrageous,...
  7. Replies
    14
    Views
    621

    I install Bryant(factory installed txv) and ADP(...

    I install Bryant(factory installed txv) and ADP( factory installed txv). I'm assuming that the coils in the (Remote)subdivision are Carrier because i know the the company that did alot of work in...
  8. Replies
    14
    Views
    621

    Reason i ask about coil is because i usually just...

    Reason i ask about coil is because i usually just use fan coil with heat strip as auxillery heat(2nd stage) and i figured it was a bi-flo built in. I think i have installed 4 of them type. They all...
  9. Replies
    14
    Views
    621

    thank you for the info. If the existing coil is a...

    thank you for the info. If the existing coil is a typical TXV coil, it doesn't need to be replaced with a a specific bi-flo txv??

    Winter can be cold in some areas here. Sometimes in the area where...
  10. Replies
    14
    Views
    621

    yep, sure am. Just thinkin what is needed to...

    yep, sure am. Just thinkin what is needed to convert. I don't install alot of them out here, but i have. Typically they don't do the greatest cause we are below 30 degress in the winter, but these...
  11. Replies
    12
    Views
    5,140

    I would never install a Lennox!!! the extra...

    I would never install a Lennox!!! the extra money doesn't buy you anything. Except for more expensive parts to replace later. If this is a change out situation, there can be no guarantee if the...
  12. Replies
    14
    Views
    621

    Propane to Heat-pump

    Im a HVAC contractor in Utah. Been thinkin bout a subdivision with only propane(no Nat option) and high heat bills. Im thinkin of proposing to people about converting to heat pump systems.

    Im...
  13. Replies
    8
    Views
    746

    How can i get on the map???

    How can i get on the map???
  14. Replies
    8
    Views
    746

    thank you!!

    thank you!!
  15. Replies
    8
    Views
    746

    I see what you guys are saying :) thanks

    I see what you guys are saying :) thanks
  16. Replies
    6
    Views
    2,684

    I'd say if supply vents are in the floor(by...

    I'd say if supply vents are in the floor(by windows), baseboard returns are ok. Or... if in the ceiling, one in each corner of room(return-supply) is nice.
  17. Replies
    8
    Views
    746

    Costs and confusion :/

    Are there any programs(Duct-sizing, CFM vs Tonnage) out there that are actually simple, easy to use, and cheap, or even free??? Everyone wants to give me answers about mathamatical problems that make...
  18. Replies
    3
    Views
    699

    Pro Memeber???

    UUUUGH!!! What is a pro member??? Dang, it seems hard to post a general question. I wishg it was easier to navagate in this site, or to just post a question
  19. Replies
    13
    Views
    1,581

    Yes, i'm in the trade. Have my S350 in utah. ACE...

    Yes, i'm in the trade. Have my S350 in utah. ACE HVAC, LLC is my company I own. I ask questions just to get opinions Duct sizing, tonnage vs. CFM. Haven't gotten the revenue yet to buy these...
  20. Replies
    13
    Views
    1,581

    thank you and i agree. Just a situation i ran...

    thank you and i agree. Just a situation i ran across and thinkin i need to add more return air to system
  21. Replies
    13
    Views
    1,581

    i Agree, and thank you. It's just a situation i...

    i Agree, and thank you. It's just a situation i ran across and as a fix, i was thinking i need to add more return air
  22. Replies
    13
    Views
    1,581

    CFM question!!!!

    14 inch flex can carry how many CFM????

    12 inch flex can carry how many CFM???

    How much CFM can pass through 20x20 filter grill????

    Does a 4 ton package unit need at LEAST 1200 CFM??? or...
  23. Replies
    2
    Views
    347

    Determine Friction loss

    I'm trying to get familiar with duct calculator so... How do i determine what my friction loss is????
  24. Thread: Return air

    by jeremyjp
    Replies
    3
    Views
    442

    Return air

    On a 5 ton package unit, how much cfm for return air? or what size round pipe does that equate to?? 22 inch??
  25. Replies
    3
    Views
    1,209

    CFM- Return duct size

    How much CFM for 3 ton package unit??? This one i ran across today has 2-12 inch round. Certainly doesnt seem like enough.

    What is "one way size' min needed?? 16 round or 18??

    How bout for 5...
Results 1 to 25 of 30
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event