  1. Replies
    40
    Views
    4,383

    Just wondering when you had the air handlers...

    Just wondering when you had the air handlers hooked to B & C then moved to A & B you did move the line set from C to A I hope.
  2. Replies
    31
    Views
    2,935

    Dam What a Hack!!!!!

    Dam What a Hack!!!!!
  3. Replies
    40
    Views
    4,383

    If you do not have any of the wires from the air...

    If you do not have any of the wires from the air handlers crossed up I would be looking at the grounding. All mini splits can and do get stupid if not grounded properly.
  4. Replies
    40
    Views
    4,383

    The led will stop and start again. Number of...

    The led will stop and start again. Number of blinks after stop is the fault code.
  5. Replies
    40
    Views
    4,383

    What are the flash code on the Operation LED and...

    What are the flash code on the Operation LED and on the Timer LED?
  6. Replies
    40
    Views
    4,383

    OK check on the earth grounding to the system. We...

    OK check on the earth grounding to the system. We have in the past had to add an earth ground with in 3' of the condenser. Best of luck.
  7. Replies
    40
    Views
    4,383

    You may have to cut power to the condenser and...

    You may have to cut power to the condenser and hold untill all leds go out for the computer to reset. When fujisu is powered up it runs a scan to know what it hooked up to it.
  8. Replies
    40
    Views
    4,383

    Did you ever wonder why they are marked A B C?

    Did you ever wonder why they are marked A B C?
  9. Replies
    21
    Views
    3,203

    Is the LG cooling only or Inverter ?

    Is the LG cooling only or Inverter ?
  10. Replies
    4
    Views
    648

    looks like you have found the problem. hook up...

    looks like you have found the problem. hook up recovery. Keep learning.
  11. Replies
    43
    Views
    2,512

    Check with Heil for 24" back sweep fan blade lot...

    Check with Heil for 24" back sweep fan blade lot less sound. AT 71dba you have a long way to go to get 40. Good luck
  12. Replies
    2
    Views
    475

    Yes it keeps the sman3 from getting beat up in...

    Yes it keeps the sman3 from getting beat up in the van.
  13. Replies
    28
    Views
    1,779

    Sman 3 Love it.

    Sman 3 Love it.
  14. Replies
    10
    Views
    4,588

    Go to www.forwardthinking.honeywell.com As I...

    Go to www.forwardthinking.honeywell.com As I remember from the webcast with Nordyne the gateway is like any wireless hub.
  15. Replies
    3
    Views
    462

    R 4.5 or 2" in conditioned area and R 8 or 3" in...

    R 4.5 or 2" in conditioned area and R 8 or 3" in unconditioned.
  16. Thread: UTL Ductless

    by tcktech
    Replies
    2
    Views
    1,389

    Check your install manual. The inverter type unit...

    Check your install manual. The inverter type unit has high voltage from outdoor to indoor. We use 14/4. High voltage Low amp.
  17. Replies
    6
    Views
    639

    Have had mine for about 30 days not one problem....

    Have had mine for about 30 days not one problem. I love working with it.
  18. Replies
    5
    Views
    791

    Just got my new Sman3 from supply house Monday...

    Just got my new Sman3 from supply house Monday Noland Co. $320.00 +tax. Nice set up.
  19. Replies
    6
    Views
    701

    Hoping the Sman3 is all you guys say it is. Still...

    Hoping the Sman3 is all you guys say it is. Still wating for mine to get hear. Supply co. ordered me one, said I might have it by Christmas Ha Ha.
  20. Replies
    32
    Views
    2,882

    Are you talking about Inverter type unit?

    Are you talking about Inverter type unit?
  21. Thread: Wire size

    by tcktech
    Replies
    29
    Views
    2,803

    Run two 6awg and one 8awg ground. on a 50 amp....

    Run two 6awg and one 8awg ground. on a 50 amp. cya.
  22. Replies
    13
    Views
    4,844

    I have been using a pullzall from warn works that...

    I have been using a pullzall from warn works that I bought from tractor supply. 115v only 15lb. with a 15ft wire rope does a fine job on compressors and lifting air handlers in to the attic.
  23. :eek:From the look of the blower and motor end...

    :eek:From the look of the blower and motor end that unit needs a full clean by a HAVC Pro. The Coil will be pig dirty. Cleaning crews have no clue as to AC work. It will be costing you on elect....
  24. Replies
    45
    Views
    3,017

    Have a Pro come out and do a full chem. clean on...

    Have a Pro come out and do a full chem. clean on your system, check charge, air flow and all. A lot of home owners do not think about maintance on the AC untill it does not work. If your unit is 3-4...
  25. Thread: Water temp

    by tcktech
    Replies
    95
    Views
    10,087

    :confused:Are your two systems runing off of one...

    :confused:Are your two systems runing off of one well system, or are there two? If the two are runing off one are check valves and flow valves installed at each set of pumps? I would still be looking...
  26. Thread: Water temp

    by tcktech
    Replies
    95
    Views
    10,087

    :( Why would it take 7 days for the earth to drop...

    :( Why would it take 7 days for the earth to drop the drill temp? If it takes that long to drop from 180f to 68f not a lot of transfer.
    We do not drop the drill slag in the wells it will take for...
  27. Thread: Water temp

    by tcktech
    Replies
    95
    Views
    10,087

    :eek: with 5 wells @ 150' in limestone no way you...

    :eek: with 5 wells @ 150' in limestone no way you should have ewt that high. The wells need to be grouted in from the bottom up. piped between wells as first in last out. flushed with high flow rate...
  28. Thread: Water temp

    by tcktech
    Replies
    95
    Views
    10,087

    :confused:Have your installer back out to check...

    :confused:Have your installer back out to check proper water in and out temps. Check the psi drop water in and out to see flow rate 5 ton= 15 gpm.
    5 wells could be air in lines.
  29. Replies
    2
    Views
    528

    Hand-Held Winch

    Has any one used the Warn Works PullzAll hand held winch? It is 120v 1000lbs. capacity. Looks like a good tool to have.
  30. :)Nice install. Are you runing two units from one...

    :)Nice install. Are you runing two units from one set of pumps?
  31. Replies
    7
    Views
    710

    Digital inspection camera

    :) I have just bought a Milwaukee 12 volt digital inspection camera. Have not had a call to use it yet, but looks like a good tool.
    Has anyone used this one?
  32. Replies
    18
    Views
    1,340

    :)Franklin,TN Self employed HVAC/R contractor. A...

    :)Franklin,TN Self employed HVAC/R contractor. A little slow for new construction. Res. service is ok.
  33. :confused:Have your contractors done manual J...

    :confused:Have your contractors done manual J load calculations?
  34. Replies
    13
    Views
    1,188

    :) Like I do good laptop and HVAC-Calc.

    :) Like I do good laptop and HVAC-Calc.
  35. Replies
    25
    Views
    3,083

    Have been useing my own robinare 4cfm for a...

    Have been useing my own robinare 4cfm for a number of years, no problems also have the YJ R60 recovery fine equipment.
  36. Thread: Help Please!!!

    by tcktech
    Replies
    5
    Views
    631

    :eek: Call for a pro tech. your guy didn't know...

    :eek: Call for a pro tech. your guy didn't know what he was doing. Shorted or miss wired low voltage. Fried T stat.
  37. Replies
    5
    Views
    755

    :confused: What brand zone control? If Honeywell,...

    :confused: What brand zone control? If Honeywell, dats is needed.
  38. Replies
    11
    Views
    3,105

    :) We have the same code for overflow pan under...

    :) We have the same code for overflow pan under all units with float sw.
  39. Replies
    11
    Views
    3,105

    :confused: Where is the overflow pan with flot...

    :confused: Where is the overflow pan with flot sw, and is that siting dead on the conctete floor?
  40. Replies
    4
    Views
    740

    :) Thanks for the link. It looks like the one for...

    :) Thanks for the link. It looks like the one for me.
  41. Replies
    4
    Views
    740

    Professional Question

    :) What Manual J software do most professionals use. Looking for easy to use, yet capture the intent of the manual. But don't have to take out a home loan to buy.
  42. Thread: No Heat Rheem

    by tcktech
    Replies
    4
    Views
    1,447

    No Heat Rheem

    :eek: Service call today twin 125k shut down on high limit Wonder why?
    http://i165.photobucket.com/albums/u56/tcktech/AArk003.jpg
    http://i165.photobucket.com/albums/u56/tcktech/AArk004.jpg...
  43. Replies
    25
    Views
    1,648

    :) Sounds like someone did not disconect power at...

    :) Sounds like someone did not disconect power at HP before changing T stat.
    Call service tech eazy fix.
  44. Replies
    24
    Views
    1,921

    :confused: What brand zone control, & what nit...

    :confused: What brand zone control, & what nit put it outside?
  45. Replies
    21
    Views
    1,725

    :rolleyes: Time for a new Thermostat, and a senor...

    :rolleyes: Time for a new Thermostat, and a senor Tech.
  46. Thread: Rheen no heat

    by tcktech
    Replies
    16
    Views
    1,723

    :confused: The model number you listed does not...

    :confused: The model number you listed does not compute. What type system split or package?
  47. :eek: Report this DIY to the codes Dep. quick...

    :eek: Report this DIY to the codes Dep. quick before someone is dead!!!!!
    Water heater vent deth trap.
  48. Thread: wowwwwwww

    by tcktech
    Replies
    11
    Views
    2,764

    :eek: Terminal lack of intelligence.

    :eek: Terminal lack of intelligence.
  49. Replies
    4
    Views
    800

    :eek: Call in a pro Tech quick. Could be cracked...

    :eek: Call in a pro Tech quick. Could be cracked heat EX, Bad RO Only a tech should check it out. NOT DIY!!!!!!
  50. Replies
    12
    Views
    1,018

    :eek: Ask your HACK , sorry, installer if he...

    :eek: Ask your HACK , sorry, installer if he knows what ACCA Manual D is?
Results 1 to 50 of 127