Search:

Type: Posts; User: Greend88

Page 1 of 8 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    64
    Views
    1,454

    I would of made it so you could put the flapper...

    I would of made it so you could put the flapper on either side.
  2. Replies
    9
    Views
    398

    Big Ass Fans and Infrared.

    Big Ass Fans and Infrared.
  3. Replies
    18
    Views
    970

    Mueller ACR Type K and L is rated for 410A and...

    Mueller ACR Type K and L is rated for 410A and Sub-critical CO2. It has a UL Rated 700psi working pressure.

    http://www.muellerindustries.com/uploads/pdf/UL_700_psi_Announcement.pdf...
  4. Replies
    12
    Views
    399

    If its that big of a job who wrote up the...

    If its that big of a job who wrote up the contracts? I would be blaming them for any mistakes
  5. Replies
    12
    Views
    399

    Venting can be either HVAC or Plumbing.... It's...

    Venting can be either HVAC or Plumbing.... It's in both there codes. If it's not in the plumbers contract you'll have to pay more for him to do it.
  6. Thread: Used furnaces

    by Greend88
    Replies
    72
    Views
    2,713

    I see used furnaces and even new furnaces on our...

    I see used furnaces and even new furnaces on our local facebook buy sale and trade groups all the time going for $ to $ bucks all the time. Heck I bought a 92% Condensing Lennox for $ nothing wrong...
  7. Thread: quote

    by Greend88
    Replies
    5
    Views
    498

    http://www.scotsman-ice.com/ Find your Local...

    http://www.scotsman-ice.com/ Find your Local Distributor and Talk to them. Top of the Screen is the link to search for Distributors
  8. Replies
    49
    Views
    1,402

    Throw the spare on drive slower to a repair shop...

    Throw the spare on drive slower to a repair shop and buy a new tire. Hope you don't expect to be compensated for sitting on your arse doing nothing....
  9. Replies
    11
    Views
    513

    Idk but I'm betting you'll be back to replace...

    Idk but I'm betting you'll be back to replace something else soon....
  10. Replies
    18
    Views
    1,395

    Home depot sells a Cheap Ridgid one for $79....

    Home depot sells a Cheap Ridgid one for $79. Basic and No Recording though. http://www.homedepot.com/p/RIDGID-Micro-CA25-Inspection-Camera-40043/203258908
  11. Replies
    11
    Views
    526

    They Make Nitro Cars/Trucks with Reverse.

    They Make Nitro Cars/Trucks with Reverse.
  12. Replies
    34
    Views
    3,237

    They make mini-android tablets for the guys with...

    They make mini-android tablets for the guys with flip phones. About the size of a smart phone and cheap. Should work well with this and any other new testing devices coming to the HVAC market for...
  13. Replies
    17
    Views
    1,338

    Our Local Amazon did the same thing a year ago....

    Our Local Amazon did the same thing a year ago. One of the company's i've worked for tried to get them to go with a centralized system but there argument was they just lease there warehouses and...
  14. Replies
    36
    Views
    1,622

    Tip: Get rid of the manifold and long hoses. Get...

    Tip: Get rid of the manifold and long hoses. Get Vac Rated Hoses and Connect Directly Pump to System.
  15. 5 months won't even teach you the basics. Look...

    5 months won't even teach you the basics. Look into your Local Apprenticeship. 5 Years down here and all you pay for is your Books each year which is only ~$300 bucks a year. Plus you get to work and...
  16. That Running Time meter would be the cheapest but...

    That Running Time meter would be the cheapest but if you want to know the actual cycles and whether there's any water in the pit at the correct level when it runs then I would use an Arduino....
  17. Replies
    33
    Views
    2,890

    And Compared to the accuracy of the BluVac's 5% ...

    And Compared to the accuracy of the BluVac's 5%
    http://www.accutools.com/product/bluvac-digital-vacuum-gauge/#3
  18. Replies
    21
    Views
    1,513

    TXV or Piston? Could have a slight restriction....

    TXV or Piston? Could have a slight restriction. Any kinks in the line set? Hows the drier?
  19. Replies
    48
    Views
    2,134

    Cast Iron Fittings Can Be Found under IFGC:...

    Cast Iron Fittings Can Be Found under IFGC: 403.10.4 - 5
    http://publicecodes.cyberregs.com/icod/ifgc/2000/icod_ifgc_2000_4_par042.htm

    Cast Iron Pipe is Prohibited.
  20. Replies
    48
    Views
    2,134

    The IFGC 2006 has the exact same thing under...

    The IFGC 2006 has the exact same thing under section 403.9
    http://publicecodes.cyberregs.com/icod/ifgc/2000/icod_ifgc_2000_4_par034.htm?bu2=undefined
  21. Replies
    48
    Views
    2,134

    http://www.detroitnippleworks.com/merchant-couplin...

    http://www.detroitnippleworks.com/merchant-couplings/

    Straight threads make them easy to loosen up with any type of vibration.

    The UPC 2003 Says For Fuel Gas Piping: "1209.5.7 Metalic Pipe...
  22. Replies
    15
    Views
    1,001

    Your Missing Something.... You make a loop...

    Your Missing Something.... You make a loop between the two heaters.
  23. Replies
    15
    Views
    1,001

    You can do it either Parallel or Series, both...

    You can do it either Parallel or Series, both have there pros and con's google it. And make sure to check with your Local Inspector as said above.
  24. Replies
    6
    Views
    387

    Yes you do need to be certified....

    Yes you do need to be certified. http://codes.ohio.gov/oac/1301:3-7-02

    And if you get caught here's the fine: http://codes.ohio.gov/orc/3703.21
  25. Replies
    10
    Views
    719

    Havn't Tried this but couldn't you take a dual...

    Havn't Tried this but couldn't you take a dual port manometer and cap off one port with a piece of plastic tubing with a valve. You can get them at aquarium shops. Place this tube on the manometer...
  26. Replies
    16
    Views
    1,192

    Oil Separator, and get it back to the compressor....

    Oil Separator, and get it back to the compressor. As long as it's not running 24/7 it won't hurt it. Seen Fridge Compressors last forever as airbrush compressors.
  27. Replies
    13
    Views
    1,172

    What did you set the Ice Thickness Probe? Should...

    What did you set the Ice Thickness Probe? Should be 9/32"

    http://www.manitowocice.com/asset/?id=pnvoq

    See Page 100 for setting Probe.

    "During the first 6 minutes of the freeze cycle the ice...
  28. Replies
    14
    Views
    947

    You could rewind a couple used 1200 watt...

    You could rewind a couple used 1200 watt microwave transformers (MOT's). I've seen it done to make cheap arc welders before. Just make sure there in phase and do the math to figure your winding size...
  29. Replies
    33
    Views
    3,308

    HS36 Gets my Vote Have had mine for over 2 years...

    HS36 Gets my Vote Have had mine for over 2 years and no problems at all.
  30. Replies
    19
    Views
    1,839

    Service Wrench and Extension Like everyone else...

    Service Wrench and Extension Like everyone else said ^
  31. Thread: Pulley puller

    by Greend88
    Replies
    33
    Views
    1,992

    Harbor Freight has a couple Hydraulic Pullers for...

    Harbor Freight has a couple Hydraulic Pullers for less than a $100

    http://www.harborfreight.com/catalogsearch/result?q=Hydraulic+Gear+Puller
  32. Replies
    45
    Views
    2,742

    Dont worry bout the teflon tape. I use it on all...

    Dont worry bout the teflon tape. I use it on all gas pipe never had a problem. As long as its put on correctly itll never get in the pipe.
  33. Replies
    22
    Views
    2,440

    The reason for no staybrite8 in commercial...

    The reason for no staybrite8 in commercial buildings on pipe systems would be to keep the joints from melting in a fire and introducing a ton of refrigerant.
  34. Replies
    45
    Views
    2,742

    All Appliances should be isolated, and the meter...

    All Appliances should be isolated, and the meter should be isolated before any pressure tests are done.
  35. Thread: Turbo torch

    by Greend88
    Replies
    41
    Views
    4,268

    I've brazed 3" Copper easily with a TurboTorch...

    I've brazed 3" Copper easily with a TurboTorch and there largest tip. It all depends on the tip you use.
  36. Replies
    47
    Views
    5,342

    Looks Great

    Looks Great
  37. Most good digitals are 0.5% accurate... So a 0.5%...

    Most good digitals are 0.5% accurate... So a 0.5% difference between 1% analogs and digitals.
  38. Replies
    12
    Views
    1,067

    A Good EMPulse will energize the locks and open...

    A Good EMPulse will energize the locks and open them.

    Also Car's with Tire Sensors,Blue Tooth, OnStar. The CANBus can be wirelessly hacked to Unlock and Disarm the Factory Alarm.
  39. Replies
    2
    Views
    500

    Is there any booster pumps tied in right after...

    Is there any booster pumps tied in right after the backflow? Also any large call for water and sudden stop will cause them to pulsate. Anytime the pressure after the backflow is greater than the...
  40. Replies
    9
    Views
    787

    Have you guys read the ingredients on those flush...

    Have you guys read the ingredients on those flush kits? Mostly Acetone.... At least the ones sold around here are.
  41. Replies
    45
    Views
    5,959

    When your doing liquid remember to meter it with...

    When your doing liquid remember to meter it with your gauges. Start closed then work to open making sure your not overpowering the unit. I've seen way to many techs slam them with TOO much liquid and...
  42. Replies
    28
    Views
    2,203

    I believe this one was leaking internally....

    I believe this one was leaking internally. Swapped it out the next day and no more problems.

    446671446681446691446701446711446721
  43. Replies
    5
    Views
    689

    http://www.digikey.com/schemeit

    http://www.digikey.com/schemeit
  44. Replies
    27
    Views
    4,450

    Called a Wrap-Around ^^^

    Called a Wrap-Around ^^^
  45. Replies
    6
    Views
    1,167

    no duct board. its an angle iron support stand....

    no duct board. its an angle iron support stand. with metal duct through wall. insulated with foil backed foam.
  46. Thread: Tape or dope

    by Greend88
    Replies
    25
    Views
    2,109

    Depends on the application But I'll usually wrap...

    Depends on the application But I'll usually wrap 3 times then dope with TruBlu. http://www.rectorseal.com/index.php/rectorseal-tru-blu/ It's the only pipe dope I really like. Sometimes we double...
  47. Replies
    6
    Views
    1,167

    Our New City Municipal Center

    436151436161

    Still waiting on the Condenser Pad to be poured to set it.
  48. The ductwork looks great. But... Are you sure...

    The ductwork looks great. But... Are you sure it's safe to run that armaflex against or almost against that single wall vent connector coming right out of the right furnace? Gonna get pretty toasty...
  49. Exactly not for our kind of work unless your...

    Exactly not for our kind of work unless your driving a monster that weights more than the 10,000#'s.
  50. check out truckingks.org

    check out truckingks.org
Results 1 to 50 of 392
Page 1 of 8 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event