Search:

Type: Posts; User: kiwicontroller

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Replies
    82
    Views
    27,388

    Hi Orion can you please send me the Visio...

    Hi Orion can you please send me the Visio Stencils? It would be much Appretiated mate.
  2. Replies
    3
    Views
    1,522

    Hi all, Most customers are not always happy to...

    Hi all,

    Most customers are not always happy to do a full controller retro fit and opt to go for the BCM array upgrade (BCM TUX) we however advise them to run a separate MSTP trunk to all the field...
  3. Replies
    3
    Views
    800

    TDS is the DOS TUX DDC editor (blue screen) used...

    TDS is the DOS TUX DDC editor (blue screen) used for direct conect to TUX controllers.
  4. Replies
    3
    Views
    800

    Alerton Win7

    Gidday,

    Just wanting to see if someone has succesfully installed Win7 and is running all the Alerton software?

    I have managed to re-installed and test:

    Envision BACtalk
    Envision Ibex
    W3700
  5. Try putting aladdin hasp in the google search bar...

    Try putting aladdin hasp in the google search bar and then rub you monitor screen,

    hopfully a Jeanie doesn't appear.
  6. Replies
    5
    Views
    1,328

    Check the flow direction through the valve. If...

    Check the flow direction through the valve. If that is correct check the delta P across the valve. Maybe an under sized valve.
  7. Replies
    7
    Views
    2,034

    IBW needs an ACI slot on the PC being used If...

    IBW needs an ACI slot on the PC being used

    If you do not have an aci slot you can use an XP based machine but then you will need to install envision for ibex and install an ethernet adapter.
  8. Freddy interested in my vintage copy of 3500 Iíll...

    Freddy interested in my vintage copy of 3500 Iíll throw in my 3700 version also????????????
  9. Replies
    3
    Views
    549

    Yip I think that is the one we are looking at...

    Yip I think that is the one we are looking at getting,

    but there was an issue with it, I think someone said there was a problem with the amount of device's that it could see on a trunk.

    I...
  10. Replies
    3
    Views
    549

    Alerton FST alternatives

    Hi all

    Has anybody have or know of a good fst alternative, something like the good old 2650 for ibex?

    FST is not a good look when going through major airports always get the 20 questions.
    ...
  11. Replies
    24
    Views
    2,790

    Hi guys Does anyone have a app which converts...

    Hi guys

    Does anyone have a app which converts velocity pressure to L\s?

    I know the formula but it would be cool if there was a app where you just input you velocity pressure and your duct...
  12. Replies
    14
    Views
    2,460

    If the relay is doing only a few operations per...

    If the relay is doing only a few operations per hour the relay should be fine.

    SSR's are used when multiply operations per hour are needed, like for an electric heater that pulses every couple of...
  13. Replies
    5
    Views
    1,115

    LOL Get a contractor, hopfully this guy...

    LOL

    Get a contractor, hopfully this guy does'nt rock up other wize it'll be a loooong day dude.
  14. Replies
    8
    Views
    1,056

    Cans?????? :couch: not sure Dude.

    Cans?????? :couch:
    not sure Dude.
  15. Replies
    21
    Views
    2,740

    F1 pilot that would be awsom. But I guess I'm in...

    F1 pilot that would be awsom. But I guess I'm in controls for the money............
    YE RIGHT
  16. Thread: Newbie

    by kiwicontroller
    Replies
    14
    Views
    1,366

    Some how I donít think lafam1 is aspiring to be a...

    Some how I donít think lafam1 is aspiring to be a full time Ref tech. He is the type of guy that likes to know what he has how it works and most importantly doesnít like to pay for things he doesnít...
  17. Replies
    21
    Views
    5,246

    Had an appartment block go up next to our trane...

    Had an appartment block go up next to our trane chiller and the coil facing the appartment block didnt last 12 months, the one on the other side was fine, We put it down to the building dust from the...
  18. Replies
    24
    Views
    2,790

    Hi All The only negative with using the ipod...

    Hi All

    The only negative with using the ipod touch is the wi-fi connection side of things. There are more and more apps appearing on the app store everyday. I have downloaded a few free basic apps...
  19. Replies
    10
    Views
    1,522

    www.seek.com.au

    www.seek.com.au
  20. Replies
    10
    Views
    1,522

    Hi Have you tried www.seek.co.au there are...

    Hi

    Have you tried www.seek.co.au there are usually heaps of jobs on there.

    Good luck.
  21. Replies
    24
    Views
    2,705

    Have they (the Plumbers) just decided that...

    Have they (the Plumbers) just decided that because they are working with pipe all day they might as well start installing ac units or is there some dodgy 5 day coarse they attend that certifies them?...
  22. Replies
    24
    Views
    2,705

    The pay isnít great because you need to get an...

    The pay isnít great because you need to get an electrician to come and complete your installation (wiring of the unit YOU have put in) and pay him a chuck of money because he has a card saying...
  23. Replies
    24
    Views
    2,705

    I donít have an issue with monkeys as long as...

    I donít have an issue with monkeys as long as they stay in there own tree's so to say and I really do enjoy a good banana.

    My issue is that electricians can become hvac installers over night but I...
  24. Replies
    24
    Views
    2,705

    I did a similar trade test which was in fact a...

    I did a similar trade test which was in fact a day and a half to gain my HVAC qualification and thinking back most of the test material was electrical related motor insulation testing, polarity...
  25. Replies
    24
    Views
    2,705

    So how would this trained monkey of yours know...

    So how would this trained monkey of yours know whether the unit is working after he has installed it. or does he swing off to the next install?
  26. Replies
    24
    Views
    2,705

    HVAC VS Electrical

    Hi All

    I have been doing HVAC for 12 years and have found of late that more and more electricians are becoming heat pump installers ( Here in good old New Zealand ) they do a 1 week coarse then...
  27. orion is it tooo late to also get a copy??

    orion is it tooo late to also get a copy??
  28. Replies
    6
    Views
    1,253

    Have had alot of issues with those auto Tran 851D...

    Have had alot of issues with those auto Tran 851D (config range and signal input), Try using the 750D variant much more reliable.

    They need to be installed in a none turbulent part of the duct or...
  29. Replies
    7
    Views
    1,516

    Make sure the two VLC dont have the same Mac...

    Make sure the two VLC dont have the same Mac address,
  30. Replies
    3
    Views
    1,025

    Alerton Visio block

    Hi all.

    Has anybody done a 3 unit 7 day cycle block in visio-logic and are willing to share?

    Got 3 DX units 2 run 1 standby and need to cycle every 7 days eg: week 1 units 1 and 2 run 3 standby...
  31. Replies
    11
    Views
    1,200

    Went and checked the flow direction and sure...

    Went and checked the flow direction and sure enough the valve was fitted the wrong way.

    Thanks guys.
  32. Replies
    11
    Views
    1,200

    Will do thanks.

    Will do thanks.
  33. Replies
    11
    Views
    1,200

    I will check that out. When you say the valve...

    I will check that out.

    When you say the valve needs adjusting is that just the flow through the valve? (no ballancing valves)

    I have callibrated the T-stat and the actustors operating pressure...
  34. Replies
    11
    Views
    1,200

    I've stuck a new actuator on and the new one did...

    I've stuck a new actuator on and the new one did the same so I took if off and pushed the shaft on the valve in and out a couple of time's just to make sure that there was no sh#t in the valve body....
  35. The return fan would be external to the AHU and...

    The return fan would be external to the AHU and there would be three dampers 1-fresh air 2-return air 3-spill air.

    When the out side air is low enough to use the fresh and spill air damper drive...
  36. Replies
    11
    Views
    1,200

    Buzzing Honeywell pneumatic actuator:

    History:

    Open office space converted to individual offices.
    So they had two VAV boxes connected to one pneumatic heating valve.

    Installed separate heating valves and actuators on the...
  37. Replies
    7
    Views
    738

    Try Autotran.

    Try Autotran.
  38. Replies
    6
    Views
    674

    If you want to connect via remote dial up you...

    If you want to connect via remote dial up you need the same software that is on the site PC, and you need the job data base. So you would need Ibex for windows installed on the machine you will use...
  39. Replies
    6
    Views
    674

    Hi mate, (There's no phone line or modem at...

    Hi mate,

    (There's no phone line or modem at the PC.) the modem will be connected to one of the apex controllers and the phone line will be connected to the modem. Is there no software ( IFW or...
  40. Replies
    6
    Views
    674

    We still use the 3700 dial up software but why...

    We still use the 3700 dial up software but why are you after the 3700 dial up software if the site was upgraded to IFW.

    You best bet is to locate the Apex that has the modem connected to it check...
  41. Replies
    4
    Views
    728

    Hi mate These sensors are auto addressing and...

    Hi mate

    These sensors are auto addressing and when first powered up the main module detects all the sensors on the comms trunk and then assigns them addresses.

    You are able to determine the...
  42. Replies
    339
    Views
    49,200

    Auckland New Zealand / South Africa 12 years...

    Auckland New Zealand / South Africa

    12 years HVACR
    2 years DDC Engineering

    Everything from window units to chillers,
    One good thing about the industry there's always something to learn.
    ...
  43. Replies
    9
    Views
    1,157

    Hi Conventional Thermostat Interface (CTI)....

    Hi

    Conventional Thermostat Interface (CTI). which means you would need to add a T-stat to the CTI if you are replacing the BMS system. The T-stat you connect to the CTI should have provision for a...
  44. Replies
    4
    Views
    728

    Yip Iv'e checked that I have wired them Separatly...

    Yip Iv'e checked that I have wired them Separatly and can only see the third sensor when connected. I'm beginning to wonder if the other two sensor's have so sort of problem. (faulty):(
  45. Replies
    4
    Views
    728

    Honeywell Refrigerant detectors

    Hi All

    We have installed a Honeywell Controller module :301EM with 3 R410a detector module's. We have run a 24vac daisy chained power supply and a 2 pair comms from the main module to the 3 sensor...
  46. Replies
    19
    Views
    16,011

    Well it doesnít get much further then this ( NEW...

    Well it doesnít get much further then this ( NEW ZEALAND ) I have replaced a invertered compressor in a city multi Mitsh and its not much different you do your evacuation strip out the old compressor...
  47. Replies
    12
    Views
    4,018

    At the time of installation was there any brazed...

    At the time of installation was there any brazed joints, if so was there nitrogen pumped through the system if not the oxidization affect on the inner copper tube would cause the discoloring of the...
  48. Replies
    4
    Views
    3,627

    The delay time is built into the controller, I...

    The delay time is built into the controller, I would carry out this test with the compressor contactor off because as soon as you pull that wire the reversing valve is going to de-energize and the...
  49. Replies
    16
    Views
    1,611

    I would rather find the solution to why the LP is...

    I would rather find the solution to why the LP is dropping that low on start up in the first place the delay on break relay is mearly a Band-Aid solution check the super heat and LP cut out settings.
  50. Replies
    19
    Views
    2,598

    That all sounds ok,it looks like you have lost...

    That all sounds ok,it looks like you have lost the DDC in the controller do you have a saved backup of that controllers DDC that you can re-send to the controller?
    Is this job a Ibex upgrade to...
Results 1 to 50 of 56
Page 1 of 2 1 2

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Comfortech365 Virtual Event