  1. i would not be concerned about the small...

    i would not be concerned about the small difference in piston size ,my concern would be if the unit refrigerant charge is correct.
  2. get charged to dispose of something they sell for...

    get charged to dispose of something they sell for scrap:gah:
  3. Replies
    7
    Views
    338

    Its symptomatic of world wide out sourcing of...

    Its symptomatic of world wide out sourcing of parts
  4. Replies
    8
    Views
    225

    :worthless:

    :worthless:
  5. Replies
    6
    Views
    279

    I would bet that all you really need is a evap...

    I would bet that all you really need is a evap coil ,keep looking and you find some low bid hack that is more than willing to install a new outdoor 410a unit on your existing evap coil
  6. Did he open the coil and find the leak with...

    Did he open the coil and find the leak with bubbles ,could be a rubbed through feeder tube or something else easy to fix
  7. Thread: Gays

    by catmanacman
    Replies
    23
    Views
    554

    guess i should have named it gender benders

    guess i should have named it gender benders
  8. Thread: Gays

    by catmanacman
    Replies
    23
    Views
    554

    i quess he got tired of watching the kardachians...

    i quess he got tired of watching the kardachians get all the attention so he had to do somthing dramatic to get som attention
  9. Replies
    18
    Views
    777

    if it is not leaking leave it .

    if it is not leaking leave it .
  10. Thread: Gays

    by catmanacman
    Replies
    23
    Views
    554

    Gays

    bruce jenner is proof that homo's choose the life and are not borne that way . although i think it is a way for this piece of crap to bring attention to himself
  11. you can get a propane tank and a gas furnace...

    you can get a propane tank and a gas furnace ,although probably wont save any money
  12. Replies
    13
    Views
    370

    have your tech use a decent 440 volt run cap and...

    have your tech use a decent 440 volt run cap and find what is burning up the transformer
  13. the 30 mf is probably the compressor side and the...

    the 30 mf is probably the compressor side and the 6 is the fan side
  14. Replies
    14
    Views
    653

    what type of metering device do you have and is...

    what type of metering device do you have and is it working
  15. you need to find the leak first probably the...

    you need to find the leak first probably the evap coil
  16. Replies
    129
    Views
    2,405

    at this point i will vote for Trump ,of course...

    at this point i will vote for Trump ,of course subject to change with out notice
  17. Replies
    12
    Views
    365

    yes you will be oversized although a 28 years old...

    yes you will be oversized although a 28 years old it will need replaced soon enough
  18. Replies
    26
    Views
    974

    code or not that airhandler needs a auxillary...

    code or not that airhandler needs a auxillary drain pan under it with a safety cuttoff switch , looks like low bidder work to me .some day water will leak through the ceiling, hope your not out of...
  19. Replies
    6
    Views
    241

    steam humidifiers work much better than bypass...

    steam humidifiers work much better than bypass humidifiers on heat pumps anyway .
  20. never had a Trane rep show up on a job to check...

    never had a Trane rep show up on a job to check the line set
  21. Replies
    14
    Views
    843

    is it a low bid install by chance. just wondering...

    is it a low bid install by chance. just wondering because it appears the installer did not have a tubing bender
  22. rule #1 in trouble shooting a hvac unit is verify...

    rule #1 in trouble shooting a hvac unit is verify airflow
  23. Replies
    4
    Views
    308

    i would start by having your contractor check the...

    i would start by having your contractor check the incoming high voltage
  24. if you replace the air handler with a tam7 it has...

    if you replace the air handler with a tam7 it has a r22/410 switch you just set it to the r22.i would not put a coil in, go with a new air handler it has a 10 year warranty
  25. Replies
    12
    Views
    406

    Same crap differnt flavor

    Same crap differnt flavor
  26. The weigh in charge is the starting point then...

    The weigh in charge is the starting point then you adjust the charge using subcool and superheat . As for me i have no issue showing the home owner the superheat and subcool readings then writing the...
  27. Replies
    20
    Views
    758

    sounds like the heat strip is on

    sounds like the heat strip is on
  28. Replies
    15
    Views
    405

    is it a heat pump ,

    is it a heat pump ,
  29. Replies
    1
    Views
    217

    Pictures would be very helpfull

    Pictures would be very helpfull
  30. My mistake he is correct

    My mistake he is correct
  31. I would take the carrier

    I would take the carrier
  32. depends on what you classify as not much

    depends on what you classify as not much
  33. Replies
    14
    Views
    929

    i think part of it is the weight on the data...

    i think part of it is the weight on the data plate is for the smallest matched evap coil .
    when a larger coil is used to increase seer you have to add or the larger coil also.
  34. Replies
    7
    Views
    334

    i hear the load calc ,although if that unit has...

    i hear the load calc ,although if that unit has kept the house comfy for 30 years.
  35. Replies
    10
    Views
    301

    is the board seeing a y call

    is the board seeing a y call
  36. Replies
    7
    Views
    343

    did they not have a leak detector

    did they not have a leak detector
  37. dip 5and 6 should be on for comfort r

    dip 5and 6 should be on for comfort r
  38. the entire units is a good canidate for...

    the entire units is a good canidate for replacement
  39. that very small amount of air leakage is nothing...

    that very small amount of air leakage is nothing to worry about
  40. a service tech with a meter will be able to sort...

    a service tech with a meter will be able to sort it out , at least you dont have to wait all day for it to quit.
    you got a extra year out it
  41. did you pay to transfer the warranty. sounds...

    did you pay to transfer the warranty.
    sounds like he pulled out the expansion valve and installed a piston .
    due to the failure rate of txv's probably did you a favor
  42. Replies
    18
    Views
    466

    contactors need replaced if they look worn out or...

    contactors need replaced if they look worn out or have voltage drop ,beside much cheaper than a compressor
  43. has anybody capped the drain line outside the...

    has anybody capped the drain line outside the unit and filled the drain pan with water to see if it is cracked , or bring a big peice of plexiglass to cover the opening and run the unit to see what...
  44. A savy tech could make it work ,sounds like you...

    A savy tech could make it work ,sounds like you may have found one ,maybe you misunderstood the airflow
  45. Have your contractor show you the seer and hspf ...

    Have your contractor show you the seer and hspf difference of the 2 airhandlers
  46. Does the evap coil have a txv to meter the...

    Does the evap coil have a txv to meter the refrigerant
  47. Did the old one look like the points were burned

    Did the old one look like the points were burned
  48. i agree

    i agree
  49. is the insulation in the unit wet , if so the...

    is the insulation in the unit wet , if so the unit will condensate
  50. i think your on the right track ,any worth while...

    i think your on the right track ,any worth while tech will have a contactor on his truck
Results 1 to 50 of 1000