  1. Replies
    12
    Views
    451

    I would check for missing or wrong size piston.

    I would check for missing or wrong size piston.
  2. Replies
    44
    Views
    1,783

    I replaced a Bristol in a 1995 Goodman condensing...

    I replaced a Bristol in a 1995 Goodman condensing unit five years ago. Used the OEM one. Old compressor had bad valves and the evaporator coil was plugged full of dirt. Still running OK. I am...
  3. Replies
    4
    Views
    349

    Johnstone sells a 1/2" Acme connector(Automotive)...

    Johnstone sells a 1/2" Acme connector(Automotive) to 1/4" connector.
  4. Replies
    21
    Views
    1,391

    You mean its not a "Polar Vortex"? LOL

    You mean its not a "Polar Vortex"? LOL
  5. Replies
    22
    Views
    1,884

    We have 400hp dc motors that we meg that long,...

    We have 400hp dc motors that we meg that long, but for small compressors (5 tons or less) the reading usually stabilizes within a minute or two.
  6. Replies
    22
    Views
    1,884

    Megger Readings.

    Serviced a Carrier 5-ton RTU (3ph-480V). Found compressor contactor bad and replaced it. Took megger readings before starting up compressor. Read between 115-125 mohm to ground on all three
    legs....
  7. Replies
    43
    Views
    2,615

    Didn't you get the memo from Al Gore? Its "Global...

    Didn't you get the memo from Al Gore? Its "Global Climate Change"
  8. Replies
    44
    Views
    5,925

    This thread reminds me when I first started out...

    This thread reminds me when I first started out when I was doing R12-R134a retrofits on the cars. The instructions said to drain all of the old oil and add the POE oil charge. I just simply added the...
  9. Replies
    44
    Views
    5,925

    I am willing to bet that the reason for the...

    I am willing to bet that the reason for the compressor failure has nothing to do with the retrofit.
  10. Didn't the same thing happen to "Dog the Bounty...

    Didn't the same thing happen to "Dog the Bounty Hunter"? He said some inapproprate remarks about African Americans, and yet his show is still on the air. If they do not bring Phil back, then A&E is a...
  11. Replies
    44
    Views
    5,925

    Did my first R22 to R407C conversion today on an...

    Did my first R22 to R407C conversion today on an electronics cabinet A/C. It seems to be working well. It seem to use less refrigerant than R22, but it is low ambient(68 degrees) inside the plant...
  12. Replies
    66
    Views
    3,813

    Yeah, and I bet that there are no gun crimes...

    Yeah, and I bet that there are no gun crimes committed in NYC. LOL
  13. Replies
    35
    Views
    2,453

    Didn't we go through this before a few years ago...

    Didn't we go through this before a few years ago with OJ? The lord works in mysterious ways!
  14. Replies
    44
    Views
    5,925

    Has anyone used the Supco 88 with AB oil...

    Has anyone used the Supco 88 with AB oil sucessfully?
  15. Replies
    67
    Views
    5,360

    I guess the point I was making was about "Karma"...

    I guess the point I was making was about "Karma" It always has a way of catching up with you. I think this applies to both OJ and George Zimmerman.
  16. Replies
    67
    Views
    5,360

    Kinda like what happened to OJ.

    Kinda like what happened to OJ.
  17. Replies
    44
    Views
    5,925

    I am wondering if you can "get away" with not...

    I am wondering if you can "get away" with not changing the mineral oil in the RTU since your pipng in a RTU is alot closer than a split system.
  18. Replies
    44
    Views
    5,925

    It will be intersting to see if how these systems...

    It will be intersting to see if how these systems stand up to the test of time. We have alot of R22 RTUs and I have leaning toward R407c since it has the least amount of capacity lost. I like this...
  19. The car companies are starting to use HC...

    The car companies are starting to use HC refrigerants in the new cars. R134a is being banned in Europe and is being replaced with hfo-1234f. Mercedes is making a big stink about it and GM is starting...
  20. Thread: mo99 problems

    by mcewans
    Replies
    45
    Views
    5,680

    Any residential splits with MO and Supco 88?

    Any residential splits with MO and Supco 88?
  21. Replies
    10
    Views
    1,063

    Isn't 22 degrees a high for subcooling...

    Isn't 22 degrees a high for subcooling espesically with a 30 degree SH?
  22. Thread: soft solder

    by mcewans
    Replies
    27
    Views
    3,640

    The person who soldered that condenser obviously...

    The person who soldered that condenser obviously didn't prep the lines correctly. Maybe he used the wrong flux and that's why the leaks formed. I have both brazed with 15% rods and used Staybrite 8....
  23. Replies
    23
    Views
    3,927

    Its cheaper from a breakdown point of view that...

    Its cheaper from a breakdown point of view that you are not straining the motor as much by cycling it as oppsoed to running it continiously. Electrical usage will about the same in either case.
  24. Replies
    48
    Views
    6,516

    I have found the opposite to be true. If you have...

    I have found the opposite to be true. If you have more subcooling, then you have more liquid and therefore fewer bubbles. Think about it, if your subcooling is low, then you won't have enough liquid...
  25. Replies
    48
    Views
    6,516

    This is the reason for the bubbles.

    This is the reason for the bubbles.
  26. Replies
    39
    Views
    7,827

    I checked, and this works with the FocusPro...

    I checked, and this works with the FocusPro Series. I am not sure about the VisionPro Series.
  27. Replies
    39
    Views
    7,827

    I think you can solve this problem by hooking up...

    I think you can solve this problem by hooking up the C terminal to the common on the 24V. When power is lost, the compreesor is "locked out" and won't start up until the lockout delay in the...
  28. Replies
    58
    Views
    8,568

    Every time you open the system, you introduce...

    Every time you open the system, you introduce moisture into the system. Granted if you evacuate below 500 microns, you will get most of the mositure out, but not all of it. That is the purpose of the...
  29. Replies
    58
    Views
    8,568

    Look at it this way, unless you know exactly how...

    Look at it this way, unless you know exactly how the system was installed in terms of evacuation, you should always remove the filter/dryer inside of the system. Unless you measure the pressure drop...
  30. Replies
    18
    Views
    2,460

    Did the compressor part of the capacitor go bad...

    Did the compressor part of the capacitor go bad or the condenser fan motor part? If it is the same part of the capacitor each time it goes bad, then I would look elsewhere for a problem.
  31. Replies
    67
    Views
    15,269

    I learned how to solder first before brazing....

    I learned how to solder first before brazing. Even with brazing, I always cleaned the pipe connections just like with soldering. I always figured you can still get a bad sonnection with dirt or oil...
  32. Replies
    67
    Views
    15,269

    John, Have you ever had any issues with...

    John,

    Have you ever had any issues with inspectors when using Staybrite on installing new systems, since most HVAC manufacturers reccommend brazing the line sets? By the way I am with you with...
  33. Replies
    67
    Views
    15,269

    What is Bridget?

    What is Bridget?
  34. Replies
    17
    Views
    2,382

    Air flow may be a bit on the high side. SH is low...

    Air flow may be a bit on the high side. SH is low and SC is too high.
    Is this a matched system?
  35. Replies
    17
    Views
    4,182

    Check internal wiring of compressor.(Voltage...

    Check internal wiring of compressor.(Voltage selection)
  36. Replies
    61
    Views
    8,291

    What is the difference between city water and...

    What is the difference between city water and rain water?
  37. Its "B-Phase" grounded." Really!:grin2:

    Its "B-Phase" grounded." Really!:grin2:
  38. Thread: Support for

    by mcewans
    Replies
    8
    Views
    992

    How would it be better? The whole point of...

    How would it be better? The whole point of purging with nitrogen is to displace oxygen. I would think that any gas could be used in theory provided it is pure, does not react with oxygen and is free...
  39. Replies
    17
    Views
    1,943

    That is strange, because in low temperature...

    That is strange, because in low temperature refrigeration, you pump down the system at the end of each run cycle. Maybe its different for A/C compressors.
  40. Replies
    47
    Views
    5,237

    I have to disagree with the above statement. If I...

    I have to disagree with the above statement. If I bring my car to a repair shop and pay to diagnose the problem, then I would expect them to tell exactly what parts are needed for repair. I am paying...
  41. Replies
    36
    Views
    5,701

    What do you mean, I saw an electrical panel like...

    What do you mean, I saw an electrical panel like that in Waukeagn, IL!
  42. Replies
    22
    Views
    2,530

    I was reading 480V phase to phase. I threw in...

    I was reading 480V phase to phase. I threw in that 277 reading to let you know I had good power on all three legs. Anyway I tried it again this morning after leaving the unit locked out overnight....
  43. Replies
    22
    Views
    2,530

    Each leg is 277 volts. I will let it set...

    Each leg is 277 volts. I will let it set overnight and check tommorow.
  44. Replies
    22
    Views
    2,530

    2-3ohms.

    2-3ohms.
  45. Replies
    22
    Views
    2,530

    Bad Compressor?

    Carrier Weathermaker
    Model #48DJE06620
    S/N 1590648269.
    Found unit not working on CLO. Turns on for one second and shuts down immediately. Checked HPS,LPS and temperaure switch on evaporator all...
  46. Replies
    47
    Views
    7,650

    Since your Mom has one, that would be a good...

    Since your Mom has one, that would be a good training exercise for you to see if you can get that old one to work. Based on your posts, it sounds like you want to "dive" into this because curiousity...
  47. Replies
    25
    Views
    1,118

    Then apply for Pro status and you will have a...

    Then apply for Pro status and you will have a wealth of information at your fingertips.:yes:
  48. Replies
    12
    Views
    911

    There are alot of factors in considering repair...

    There are alot of factors in considering repair vs. replacement. First and most important is the condition of your current furance. Has the furnace been giving you problems or if this the first time...
  49. Replies
    19
    Views
    1,887

    This should not be an issue as long as you have...

    This should not be an issue as long as you have the proper sized circuit breaker/fuse installed upstream of the contactor.
  50. Thread: TXV hot swap

    by mcewans
    Replies
    49
    Views
    6,194

    Do you mean mean not?

    Do you mean mean not?