  1. Just something to check, but honestly Timebuilder...

    Just something to check, but honestly Timebuilder is the electrical wizard and can help more than I can.
  2. 23 is low for low voltage, usually will see...

    23 is low for low voltage, usually will see 25-28. Could be you incoming voltage was low as well or maybe the transformer is a multi tap and is on the wrong tap for the voltage you have.
  3. What was the exact voltage at the contactor coil...

    What was the exact voltage at the contactor coil while it was humming, prior to you touching it and it pulling in?
  4. This is the AOP section for Equipment owners(home...

    This is the AOP section for Equipment owners(home owners) to ask questions about their systems. If you are a tech, you should have posted this in the Tech to Tech chat residential section. You could...
  5. Replies
    4
    Views
    92

    This really should have been posted in the AOP...

    This really should have been posted in the AOP section, you should hit the black triangle in the bottom corner of your original post and ask them to move it there.
  6. Replies
    4
    Views
    92

    2 houses can be similar but have different heat...

    2 houses can be similar but have different heat loads, would recommend having someone do a Load on your house before you buy.
  7. Replies
    4
    Views
    92

    That unit is a 13-13.5 SEER 3 Ton unit.

    That unit is a 13-13.5 SEER 3 Ton unit.
  8. Thread: GAS Pack

    by Tech23
    Replies
    4
    Views
    120

    +1 -Depending on how long it has been running...

    +1 -Depending on how long it has been running like this, the heat exchanger needs to be checked for cracks.
  9. The system will only freeze for 3 reasons: 1)...

    The system will only freeze for 3 reasons:

    1) Low indoor airflow
    2) Low on charge
    3) Refrigerant restriction

    In your quote above it appears it was frozen and then you found it to be...
  10. Replies
    11
    Views
    232

    If you are only going to be in the home for 6-7...

    If you are only going to be in the home for 6-7 yrs, then I would not pay for high efficient equipment. I would go for the 80% furnace.
  11. Replies
    11
    Views
    244

    We can't give do it yourself advice here for your...

    We can't give do it yourself advice here for your safety and it is against the rules. The stat can be hooked up if you have 5 wires, just call a company and ask them what they would charge to...
  12. Replies
    3
    Views
    229

    If you are planning on being in the home less...

    If you are planning on being in the home less than 5 yrs, I personally would just replace the coils with OEM coils.(Be sure to ask if the replacement coils would be all aluminum. So far have had...
  13. Replies
    11
    Views
    232

    -What have your gas bills been running the last...

    -What have your gas bills been running the last couple winters?
    -What are your summer temps like?
    -Do you have AC and is it as old as the furnace?
  14. Replies
    2
    Views
    105

    Fault codes on page 8 614711

    Fault codes on page 8

    614711
  15. He also in the video points to the vent motor and...

    He also in the video points to the vent motor and calls it a the compressor. :gah:
  16. Replies
    2
    Views
    199

    I wish threads like this were started in the...

    I wish threads like this were started in the private Pro Forums. I prefer not to give to much technical help out here in the open forums where the DIY ers can read the threads. :.02:
  17. Replacing parts is not diagnosing...that's called...

    Replacing parts is not diagnosing...that's called parts changing and can be expensive. You would be money ahead to pay an experienced tech to truly diagnose the problem and would probably have unit...
  18. Thread: Its Funny to Me

    by Tech23
    Replies
    4
    Views
    378

    11:30 pm, still 95* outside, call customer: AC...

    11:30 pm, still 95* outside, call customer: AC not working, you come out and fix...$139 OT charge to come out and diagnose, repair on top of that. Ohhh, no, nooo...you ad say "Free Estimates". ...
  19. Replies
    11
    Views
    366

    Carrier Blue Book does not show a 38EM02430D, but...

    Carrier Blue Book does not show a 38EM02430D, but does show a 38EN02430...so thinking it might have been written down or typed wrong and the M in that number should be or actually is an N. If so,...
  20. Not sure what job you landed, but it takes more...

    Not sure what job you landed, but it takes more than an engineering degree to work on this equipment. If you don't know what those parts are, then for your safety and others...you should not be...
  21. Thread: Furnace Filter

    by Tech23
    Replies
    6
    Views
    270

    Oh and by the way, you may want to edit your post...

    Oh and by the way, you may want to edit your post and remove the link, as posting links to websites that sell products is against site rules. Take care and good luck.
  22. Thread: Furnace Filter

    by Tech23
    Replies
    6
    Views
    270

    You are very welcome, sorry to hear about your...

    You are very welcome, sorry to hear about your wife. I would not go above the merv 8. In a manufactured home it would be better to go with the merv 6 and look into getting a stand alone air cleaner...
  23. Thread: Furnace Filter

    by Tech23
    Replies
    6
    Views
    270

    Yes, throw that old "Hog Hair" filter away. If...

    Yes, throw that old "Hog Hair" filter away. If you can't find a 30x20, then you can put 2-16x20's in there, one on top of the other. Be sure your filter(s) completely cover the louvers in the door...
  24. Replies
    8
    Views
    320

    Yeah, sorry if I misled you, your current...

    Yeah, sorry if I misled you, your current thermostat does not communicate with your furnace and HP it simply controls them. For true communication, like Baldloonie said, you would need the York...
  25. Replies
    8
    Views
    320

    If you do get a York bid, ask them about a...

    If you do get a York bid, ask them about a communicating thermostat that would work with your furnace and heat pump communicating capable as well. :.02:
  26. Replies
    8
    Views
    320

    Your not restricted to York, get all the bids you...

    Your not restricted to York, get all the bids you want.
  27. Replies
    23
    Views
    637

    Orifice or txv?

    Orifice or txv?
  28. Learning is good, just make sure someone puts the...

    Learning is good, just make sure someone puts the numbers down and will stand behind what they say will work before you put the almighty dollar in their pocket.
  29. Cool, but did they say exactly what BTU was...

    Cool, but did they say exactly what BTU was needed to heat your house at say 10 degrees outside? The colder it gets outside the less BTU's a pump can supply to house and eventually it can supply no...
  30. Has anyone done a load calculation to see what is...

    Has anyone done a load calculation to see what is needed for your home?
  31. In my opinion, teens is pushing it...even with...

    In my opinion, teens is pushing it...even with 410A. I personally would go for duel fuel, pump with back up gas heat. :.02:
  32. I was in Birmingham in March, beautiful county by...

    I was in Birmingham in March, beautiful county by the way. How cold does it get there in the winter?
  33. Replies
    127
    Views
    2,713

    Jtrammel, here is a testimonial: 16 yrs in the...

    Jtrammel, here is a testimonial:

    16 yrs in the field, mostly resi and very light comm...did not understand how economizers worked, let alone know how to troubleshoot them. Call the supply house,...
  34. Replies
    127
    Views
    2,713

    If you don't plug them in, they never break and...

    If you don't plug them in, they never break and you don't have to troubleshoot them....DUH! :cheers:
  35. Replies
    17
    Views
    573

    There is so much I could share, but it would all...

    There is so much I could share, but it would all boil down to recommending a second opinion and tell them everything you shared here right up front. The guy behind the meat counter at the market...
  36. Replies
    2
    Views
    177

    Looks like a Tempstar serial, if so it is a 2002...

    Looks like a Tempstar serial, if so it is a 2002 model.
  37. They freeze for 1 of 3 reasons: -Low indoor...

    They freeze for 1 of 3 reasons:
    -Low indoor airflow-Which can be caused by several things
    -Low on charge-due to a leak somewhere in the system
    -Refrigerant restriction that can be several places...
  38. Replies
    5
    Views
    251

    Prior to '93 there were GU*...

    Prior to '93 there were GU* models(GU-GUP-GUPI-etc-etc-GD for downflow)-Here is an install manual for the GMP and GU series, maybe this will help.


    613351
    613361
  39. Replies
    5
    Views
    251

    GMP models did not start till 1993. The first...

    GMP models did not start till 1993. The first two numbers of serial number will tell you the year.
  40. Replies
    24
    Views
    697

    That is a pretty good savings-Differences between...

    That is a pretty good savings-Differences between the two models:

    -Seer rating of course.

    -YCJF all models/tonnages will have a Scroll compressor and must be matched with a TXV metering device...
  41. Replies
    10
    Views
    407

    I see, thanks for sharing...hope it all works out.

    I see, thanks for sharing...hope it all works out.
  42. Replies
    26
    Views
    903

    Have carried my Springfield XD45 for many yrs in...

    Have carried my Springfield XD45 for many yrs in a Supertuck IWB holster, which you can check out at crossbreedholsters.com. Am planning on switching to an XD9 service model this year. I like the...
  43. Not sure how old you unit is, model and serial...

    Not sure how old you unit is, model and serial number of unit would be nice. Also, did the tech put in any readings on any tickets, like pressures, temps, etc. Bottom line though from what you;re...
  44. It appears it has almost been 3 months since the...

    It appears it has almost been 3 months since the install. During this time, have you been to a doctor or called the HVAC company to come back out and take a look at it?

    Most companies put a 1 yr...
  45. Replies
    30
    Views
    959

    WOW, I could never do that job. I am not afraid...

    WOW, I could never do that job. I am not afraid of heights, just like to drink coffee in the mornings and heck by the time I reached my work station...I'd have to take a break to go back down to ...
  46. Replies
    127
    Views
    2,713

    I agree with Timebuilder on this, a very sore...

    I agree with Timebuilder on this, a very sore sore spot for me. I wish I could elaborate, unfortunately I cannot, but I do agree with Timebuilder's statement.
  47. Replies
    127
    Views
    2,713

    Sorry if you misunderstood, I was not saying...

    Sorry if you misunderstood, I was not saying otherwise would not be professional, was just saying I think safety could go hand in hand and not bore people to death if it is mixed in here and there.
  48. Replies
    19
    Views
    715

    It has been my understanding that because there...

    It has been my understanding that because there is so little charge is why it is recommended to have tail up to keep it in the bulb. I may be wrong, but better safe than sorry I guess.
  49. Replies
    127
    Views
    2,713

    Not saying a video solely concentrated on safety...

    Not saying a video solely concentrated on safety isn't a great idea, however I think while a person is doing a "How to" video on anything industry related it would be very easy to incorporate proper...
  50. Replies
    10
    Views
    407

    I hear the frustration in your keyboard, so...

    I hear the frustration in your keyboard, so please don't take this the wrong way. Just curious, if you do the registering for your customers, how did your distributor screw up on this. Do you do it...