  2. wow you guys are champs putting in those kind of...

    wow you guys are champs putting in those kind of hours. The most I've put in is 86 and I took a day off after to sleep for 24 more :P.
  3. Replies
    12
    Views
    977

    Good point for people not to familiar with...

    Good point for people not to familiar with amana/goodman. Also check to see if the fitting in the exhaust 90 (off the I.D. Motor) is plugged. Is the furnace sloped properly? OHM out the pressure...
  4. Replies
    9
    Views
    738

    Spot on. Everyone should assume the factory...

    Spot on. Everyone should assume the factory charge is not right. It makes you a better tech, and you will understand more by going through this process.

    Gauges, clamp probe, length on lines, coil...
  5. Replies
    10
    Views
    802

    It's always good practice to post your model #...

    It's always good practice to post your model # along with the make so people can help you out a bit more.

    We need more info on this for sure.
  6. Replies
    9
    Views
    989

    Hey there, I did clean the trap out as that was...

    Hey there, I did clean the trap out as that was part of my basic check list (I do a lot of testing). Also I did a Combustion Analysis test on it and I was getting proper readings through the flue so...
  7. Replies
    9
    Views
    989

    Thanks for the replies everyone. I'm going back...

    Thanks for the replies everyone. I'm going back there today to take the intake off to inspect it. I have put the burner door back on once it's running and the flame goes a little yellow then comes...
  8. Replies
    61
    Views
    4,242

    Yeah, I have those puppies in my truck hiding in...

    Yeah, I have those puppies in my truck hiding in the corner :P. It makes it so much easier to do a tune-up.

    Dale
  9. Replies
    9
    Views
    989

    Carrier 58mvb Intake Issues

    Hey guys! I have a 60K BTU Carrier (13 years old) that I went to tonight to fix and I have a couple questions for you.

    It was tripping on Code 34 "Ignition Fault"

    The furnace runs great with...
  10. Replies
    8
    Views
    1,512

    Also what model is it? If its a bgd34 check to ...

    Also what model is it? If its a bgd34 check to
    make sure the restrictor plate is reversed to to can slow down the combustion process.

    Dale
  11. Replies
    3
    Views
    1,394

    Unfortunately not. It's a paint and all paints...

    Unfortunately not. It's a paint and all paints have an odor. Mask everything off and use proper ventilation when you spray. Once the paint dries you won't have such a strong odor.

    Dale
  12. Replies
    8
    Views
    1,512

    First thing. You need to check the valve properly...

    First thing. You need to check the valve properly instead of just replacing it. Don't be a parts changer. There's already enough of them out there. Making sure the pilot assembly is grounded properly...
  13. Replies
    3
    Views
    1,244

    HVAC Books/Audio CD's

    I'm looking for any books relating to A/C Servicing and theory. Needs some good reading material for the truck other than manuals. Anyone know of good audio Cd's also? I'm dealing with mainly...
  14. Replies
    12
    Views
    1,633

    Here is the system i'm dealing with:...

    Here is the system i'm dealing with: http://downsview.ca/images/stories/manuals/tempmiser.pdf

    I do not have a site glass installed as stated in the manual. Yes my Sub-Cool was at 8.5 below...
  15. Replies
    12
    Views
    1,633

    not sure but I know the airflow is enough for the...

    not sure but I know the airflow is enough for the cooling load. I'm more stumped on having a 8 degree subcool with no superheat and a 20 degree delta t. this has been one of those calls for me that...
  16. That was my next response :P Dale

    That was my next response :P

    Dale
  17. Replies
    12
    Views
    1,633

    oops. I'm working with both Celsius and...

    oops. I'm working with both Celsius and Fahrenheit. Lets say it was 95+ outside.

    32x9/5+32 ;)

    1700sq/ft house 2 story if that helps. I also balanced the system according to the design specs...
  18. The gap is acceptable. You can put tape around...

    The gap is acceptable. You can put tape around there if your really concerned about it. The trap should have a breather on it. The 90 and the tee should have been reversed. Should have come out of...
  19. Replies
    12
    Views
    1,633

    TXV with no Superheat?

    OK so i have a Hi-Velocity system (Tempmiser) with a slab coil (2.5 ton) and a york 2.5 tons condenser outside. R-22 20' of line-set.

    There was a leak at his house which I identified and fixed. I...