Search:
Type: Posts; User: Jonnyb
Search: Search took 0.01 seconds.
-
07-20-2012, 02:32 AM
Thread: Oil cooler
by Jonnyb- Replies
- 7
- Views
- 677
And its 4D copeland
And its 4D copeland
-
07-20-2012, 02:31 AM
Thread: Oil cooler
by Jonnyb- Replies
- 7
- Views
- 677
Not this cooler! I have a exchanger plate. No...
Not this cooler!
I have a exchanger plate. No thermostat to control temp and the oil is at 60f.
AB oil -
07-19-2012, 12:56 PM
Thread: Oil cooler
by Jonnyb- Replies
- 7
- Views
- 677
Oil cooler
Have a r22 low temp rack with oil cooler on each compressor. What is the minimum oil temp allowed
-
06-30-2012, 01:31 PM
- Replies
- 15
- Views
- 1,394
You need a timer and off time defrost.
You need a timer and off time defrost.
-
06-27-2012, 08:56 PM
Thread: walk in starving
by Jonnyb- Replies
- 2
- Views
- 413
Check your txv strainer before. Maybe just your...
Check your txv strainer before. Maybe just your powerhead
-
06-10-2012, 08:06 AM
Thread: Hello everyone, satellite temperature?
by Jonnyb- Replies
- 18
- Views
- 907
For the post #7 If you have a rack with medium...
For the post #7
If you have a rack with medium and low temp, you will have to succion group with low temp compressor and medium temp compressor -
06-10-2012, 01:44 AM
Thread: Temperature control or Pressure control ?
by Jonnyb- Replies
- 6
- Views
- 783
When i have to replace an orit in a dual case ,...
When i have to replace an orit in a dual case , my boss whant i replace bye thermostat solenoid but i think controlled temp by pressure is better.
-
06-10-2012, 01:37 AM
Thread: Hello everyone, satellite temperature?
by Jonnyb- Replies
- 18
- Views
- 907
Never see that ? Run a complete low temp rack for...
Never see that ? Run a complete low temp rack for medium circuit. For dual temp case ok but not fresh meat.
-
06-07-2012, 10:03 AM
Thread: time for a new leak detector
by Jonnyb- Replies
- 18
- Views
- 1,234
I like the tif zx1 with 2 battery and charger....
I like the tif zx1 with 2 battery and charger. I'm not sure if i find all the leak but it make a good job
-
06-07-2012, 09:57 AM
Thread: Walk In Freezer Woes
by Jonnyb- Replies
- 68
- Views
- 5,899
With25sh it's sure you are not flooding evap. I...
With25sh it's sure you are not flooding evap. I hope to have the explication of that phenom!
-
06-05-2012, 09:35 PM
Thread: ice stopping switch
by Jonnyb- Replies
- 5
- Views
- 554
Try the eaton photoelectric sensor. Never have...
Try the eaton photoelectric sensor. Never have problem with that
-
06-02-2012, 01:59 PM
Thread: Trying to find a permanent solution..
by Jonnyb- Replies
- 18
- Views
- 1,172
Yes change the rooftop is the solution
Yes change the rooftop is the solution
-
06-02-2012, 10:43 AM
Thread: Trying to find a permanent solution..
by Jonnyb- Replies
- 18
- Views
- 1,172
Put the condensing unit on spring and forgot the...
Put the condensing unit on spring and forgot the rooftop
-
06-01-2012, 06:17 PM
Thread: Trying to find a permanent solution..
by Jonnyb- Replies
- 18
- Views
- 1,172
It vibrate without the compressor running? Maybe...
It vibrate without the compressor running? Maybe a unbalence fan blade or a bearing?
-
06-01-2012, 10:49 AM
Thread: New Guests going Pro?
by Jonnyb- Replies
- 1,144
- Views
- 111,441
Sticky: Hi, it's start with a summer job when i was 16...
Hi, it's start with a summer job when i was 16 years old and im loving it. I take the course in refrigeration. Start to works in 2004 in a small business and i do refrigeration, a/c service and...
-
06-01-2012, 10:30 AM
Thread: Refrigeration line routing and insulation
by Jonnyb- Replies
- 11
- Views
- 1,155
I pass the insulation in the hole and shoot...
I pass the insulation in the hole and shoot urethane and a caulk around after
-
05-31-2012, 10:07 PM
Thread: Refrigeration line routing and insulation
by Jonnyb- Replies
- 11
- Views
- 1,155
Dont know if its pvc but the thin sheet of white...
Dont know if its pvc but the thin sheet of white plastic
-
05-31-2012, 03:42 PM
Thread: Refrigeration line routing and insulation
by Jonnyb- Replies
- 11
- Views
- 1,155
Agree with ammonia. Stay on the roof. Nobody cant...
Agree with ammonia. Stay on the roof. Nobody cant broke the piping with a lift or anything else. Glue and tape the joint and you can recover with pvc
-
05-31-2012, 10:17 AM
Thread: Refrigeration line routing and insulation
by Jonnyb- Replies
- 11
- Views
- 1,155
Why you need to insulate the liquid line inside...
Why you need to insulate the liquid line inside the freezer?
-
Ok. I'm sure it works well with micro thermo....
Ok. I'm sure it works well with micro thermo. It's too simple versus cpc or other controller
-
Ok lol. Buy a electric pump ! When you charge by...
Ok lol. Buy a electric pump !
When you charge by the separator, you con be exact and stop just above the sighglass -
Why add the oil by the succion? Im not sure its...
Why add the oil by the succion? Im not sure its the more secur and fast method
-
Pump by the service valve. You can reduce the...
Pump by the service valve. You can reduce the head pressure or close some body. I dont see other way.
-
This thread is dead ?! How you control your case...
This thread is dead ?!
How you control your case temp? Are you controlling with a modulate superheat? -
Sporlan seem to be the best one. I have a couple...
Sporlan seem to be the best one. I have a couple of market with the carel and a lot of problem
Results 1 to 25 of 53