Search:

Type: Posts; User: MikeySq

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. its fun its not fun then its fun again.......

    its fun

    its not fun

    then its fun again....

    then.... i should shut up haha

    http://new.magic-aire.com/wp-content/uploads/2012/08/supermarket-diagram-final.jpg
  2. how is your personal ability to adapt/learn new...

    how is your personal ability to adapt/learn new things?
    if you have strong refrigeration and electrical theory you will be OK,
    on call every three weeks could be heavy??
    with service manager...
  3. Replies
    12
    Views
    494

    Nomenclature!!

    RelayCapacitorOverload-210.

    :grin2:
  4. Replies
    12
    Views
    494

    imagine that!

    imagine that!
  5. Replies
    14
    Views
    597

    Whith the price of new reach in equipment...

    Whith the price of new reach in equipment especially the stuff from China you may get your wish....
    these things are becomming more and more cheap meaning cost of repair versus cost of replacement...
  6. Replies
    23
    Views
    658

    had this one a few years back, I was not running...

    had this one a few years back, I was not running the job but looking after comississioning/start up on a market install with 2 out door racks, I wanted to put a brass 3/8 service/charging port on the...
  7. Replies
    16
    Views
    1,005

    They got more than that for sure??? i know 2,...

    They got more than that for sure???

    i know 2, now what extent inhouse "sporlan supermarket" i dont know but for knowledge of supermarkets and knowledge in sporlan thats a given for both, for sure...
  8. Shane, Will that one be in the Dallas area? or...

    Shane, Will that one be in the Dallas area? or are you travelin for this? Is it TC or SC-Cascade?

    Mike
  9. TSSA don't like any rack over 100hp without...

    TSSA don't like any rack over 100hp without having a power engineer on site full time.
    Difficult with these set ups as the MT side and the LT side are piped together unlike a cascade where you can...
  10. was chattin about this earlier with someone and i...

    was chattin about this earlier with someone and i had an oh yeah moment, as i knew this already haha u are right tho not a buy out and not Carnot!
  11. Ican see Cimco doin somethin like that!

    Ican see Cimco doin somethin like that!
  12. There are a bunch of those in Quebec and in...

    There are a bunch of those in Quebec and in Europe, they really use the heat recovery on them too!
  13. GOtta love this stuff!!!

    Curious, what are the sporlan case controllers?, are they tied in to the micro thermo system or are they the Sporlan "kelvin" style EEV controllers, or are you running Micro thermo EEV Controllers...
  14. Article: Over 125 CO2 supermarkets in North America, with many more plan

    I love this Stuff!

    Take a Peek at this Link! Are there many on here with CO2 Systems Exposure?
    Lets wait till the small CO2 Stuff comes! That will be fun too!

    Mike

    Over 125 CO2 supermarkets...
  15. Thread: hussman help

    by MikeySq
    Replies
    19
    Views
    667

    thats an odd statement> thats a typical...

    thats an odd statement>

    thats a typical refrigeration service part??
  16. Replies
    10
    Views
    817

    its all about that bore and stroke! :P

    its all about that bore and stroke!
    :P
  17. Replies
    63
    Views
    2,129

    you talkin about the high heat limit klixon wired...

    you talkin about the high heat limit klixon wired to the coils of a couple relays that switch the load side of an electric defrost with the load wires and control wires with cheap push on sta-kons...
  18. Replies
    63
    Views
    2,129

    Valves are not Low or Med or High temp, power...

    Valves are not Low or Med or High temp, power elements are, verify your valve port, I have seen a refrigerant conversion before with a SZ/VZ swap but that's not gonna cut it on a 404a sized...
  19. Replies
    63
    Views
    2,129

    You may want to re think that one back to...

    You may want to re think that one



    back to the original problem of this post, keep those coils from icing, make sure your TX is clear and you wont flood, You may want to look closely at your...
  20. Replies
    63
    Views
    2,129

    I also Agree, again Bitzer must have specified...

    I also Agree, again Bitzer must have specified this for R407a, They also use it for the LT Copeland scrolls!
    These guys used to be big on the Economized Cool vapor injection but i guess that was in...
  21. Replies
    63
    Views
    2,129

    I have a feeling I know the customer TDC is...

    I have a feeling I know the customer TDC is working with and they have chosen to go with R407a on all their new installs. Ya know its better for the environment! haha
  22. Replies
    16
    Views
    1,005

    check with Sporlan thay may do one closer to you...

    check with Sporlan thay may do one closer to you sometime throuought the year



    I hear ya I saw one of those for the first time a year or 2 ago... said to my self that looks different, hahah...
  23. Thread: uv leak dye

    by MikeySq
    Replies
    24
    Views
    1,121

    who got that UV light pic of the rack with a...

    who got that UV light pic of the rack with a gallon of Dye added? hahah
  24. Replies
    63
    Views
    2,129

    had a similar issue like this on some RL and...

    had a similar issue like this on some RL and RLN(different plenum) cases like this a while back, i found that i opened the channel where the water runs out a little, along the front of the plenum,...
  25. what is defrost frequencey? how much is door...

    what is defrost frequencey?
    how much is door opened?
    does door have strip curtains?
Results 1 to 25 of 500