    Forgive me for i,m only a student, but all the...

    Forgive me for i,m only a student, but all the data in the world will not help this compressor. It has a machical problem due to oil migraction .as for being pluged in, well i,ll let that one ride....
  2. Replies
    22
    Views
    2,333

    what should the start up be with inbox 70...

    what should the start up be with inbox 70 degrees ,store 75 degree. Is this 404a relavent to static pressure and temp as 12 was ? I do like your help very much, but i did a fill in for another...
  3. Replies
    22
    Views
    2,333

    the box is a true, the compressor is a copeland...

    the box is a true, the compressor is a copeland 230 volt sinle phase, self contained 2 door reach in freezer.Run time before dropping out 20 mintues. ref. 404a box temp 20 degrees. Pressures...
  4. Replies
    22
    Views
    2,333

    compressor loud, shuts down due to heat. cleaned...

    compressor loud, shuts down due to heat. cleaned cond. fans ok, amps low, pressure on hot start 25/180 404a refrig. has the oil moved from crank case into cond. couseing heat ? checked for loose...
  5. Replies
    26
    Views
    1,831

    wanting to go...

    Thank you James for the input and im sure they will, but now they need make shift power distribution, make shift houseing, make shift toilets, make shift stoves,make shift refrigeration, an a world...
  6. Replies
    26
    Views
    1,831

    To whom it may concern; owner/operator of...

    To whom it may concern; owner/operator of multi.tech co.
    Eletrical comm an res., heating a/c, refrigeration, kitchen eqp. trained for adverse conditions willing to relocate if thers a contractor...
  7. Replies
    31
    Views
    2,833

    i would be looking at moisture in the system as...

    i would be looking at moisture in the system as well, or maybe a mixture of refrigants . did you do a pressure temp on the system before adding ref. this will give you some ideal what type of ref is...
  8. Thread: Scottsman

    by vets
    Replies
    20
    Views
    2,248

    lost of ref.

    no ref. or a/c system should ever lose ref., you,ve got a leak somewhere. as for the 404a, put what the data plate calls for. if thers a problem call tect support
  9. Replies
    10
    Views
    1,010

    thank you kerndt, yes i did tell it back askward....

    thank you kerndt, yes i did tell it back askward. it is at the outlet. hard to think i would make a mistake as that. sorry. as for spell check, no but with the help of others im sure i could.
    ...
  10. Replies
    10
    Views
    1,010

    any amount of moister in a med or low temp cap....

    any amount of moister in a med or low temp cap. system will couse a ice burg at the enterance of the cap. couseing hi head low suction. heat tubs,(not to much)why system is running. if ice is...
  11. Replies
    10
    Views
    1,010

    any amount of moister in a med or low temp cap....

    any amount of moister in a med or low temp cap. system will couse a ice burg at the enterance of the cap. couseing hi head low suction. heat tubs,(not to much)why system is running. if ice is...
  12. Replies
    14
    Views
    2,946

    evp. plate seprated in spots not allowing heat...

    evp. plate seprated in spots not allowing heat tranfere for harvest. do not see how it worked for awhile
    the vet
  13. Thread: Scottsman

    by vets
    Replies
    20
    Views
    2,248

    flakeing evp. plate

    if this unit was 10 - 20 years old i could see it. hope food an drug or health dept steps in. replace mach. for health reason, it could be my mom or dad eating the flakes.

    ...
  14. Replies
    7
    Views
    1,637

    not sure what you are doing. they make a t...

    not sure what you are doing. they make a t fitting that will fit on the port with s valve. what are trying to attach.
  15. Replies
    18
    Views
    1,664

    do your math.

    to the none tradesman that seems to think ref. system are not THAT much. they are very exp. im sure you would do a great job an make a lot of money, but just to let you know why i would do this. it...
  16. Replies
    18
    Views
    1,664

    mid temp r22

    thats a a ROGER, i have. with the proper controls an proper setting it makes a good system. of course i am the type that will take a speaker a turn it into a microphone.

    ...
  17. Replies
    18
    Views
    1,664

    I have converted several case cooler 34- 44 temp...

    I have converted several case cooler 34- 44 temp from R-12 toR-22 without using a lig rec, now all at once the last one i installed failed. the valves went out an my supply saying the 22 system will...
Results 1 to 17 of 17