  1. This sounds more and more like a diy.

    This sounds more and more like a diy.
  2. Someone once said at 200 micron or below, oil...

    Someone once said at 200 micron or below, oil will boil off. I totally could not and will not agree.
  3. If we can't replace the lines, we do not flush...

    If we can't replace the lines, we do not flush unless it's a burn-out. Always empty an 80-CF N2 cylinder at 600-PSI you are good to go. the oldest system done that way is now
    7 years old, no problem.
  4. Replies
    7
    Views
    1,646

    You have the post count, go ahead apply for a pro...

    You have the post count, go ahead apply for a pro membership.
    You will get a lot more detailed info there.
  5. Replies
    23
    Views
    2,184

    we don't really know his heat gain, insulation...

    we don't really know his heat gain, insulation and sunlight hours.
  6. Replies
    23
    Views
    2,184

    you probably are dealing with several different...

    you probably are dealing with several different issues here (like others suggested)"
    1. water in the pan (leveling? correct drain hole? correct P trap? overflow shutoff?)
    2. wrong system charge...
  7. I don't believe it's a fan motor. If internal...

    I don't believe it's a fan motor. If internal thermal protection, how do you explain the 30-min thing and cycling the power solve the problem for another 30 min?
  8. BTW, goodman never had a model GSH140181, could...

    BTW, goodman never had a model GSH140181, could be GSH130181?
  9. Too much ifo I probably already attracted the...

    Too much ifo

    I probably already attracted the forum cop, you need to call the original installer, the system should still be in his labor warranty.
  10. Replies
    249
    Views
    22,044

    To me, it seems that there hasn't been an air...

    To me, it seems that there hasn't been an air filter installed or it hasn't been changed for a long time. The tech said the unit is "new"?
  11. Replies
    69
    Views
    13,964

    One thing I know is if my customer's condenser...

    One thing I know is if my customer's condenser needs a replacement, he won't be very happy to be forced to upgrade the whole system to R410a. Meanwhile, I have stocked up on jugs of R22.
  12. Replies
    12
    Views
    3,578

    another thought, don't just upgrade the furnace...

    another thought, don't just upgrade the furnace without investigating your duct system, most likely it won't support the full 1600cfm anyhow.
  13. Replies
    12
    Views
    3,578

    I don't know of a 4-ton coil that can be made...

    I don't know of a 4-ton coil that can be made into an "A" cabinet -
    14.5" wide. Is your current coil over hanging the furnace?

    a 1200 cfm blower may work with a 4-ton AC, it will just be a lot...
  14. Replies
    12
    Views
    1,503

    without looking into details (tonnage, IDDB/IDWB,...

    without looking into details (tonnage, IDDB/IDWB, air flow...), 250/90 sounds already too low (ODT 98F), but he "bled" it down? Did he vent R22 into the air? Is yes, report him and claim your $25000...
  15. Replies
    10
    Views
    1,106

    We had a TWE031 last week as well. My question is...

    We had a TWE031 last week as well. My question is even tho the "touch-screen" tstat was wired wrong, it doesn't seem that he damaged the air handler at all. the HVAC guy should only have needed to...
  16. Replies
    7
    Views
    509

    If a contractor installed it for you, you should...

    If a contractor installed it for you, you should get his a$$ back to check it out. If you did it yourself, I am afraid you won't get pro answers here.
  17. Replies
    16
    Views
    2,237

    I would check for refrigerant restrictions across...

    I would check for refrigerant restrictions across metering device and f/d.
  18. Replies
    17
    Views
    1,074

    you mean hall of xame?

    you mean hall of xame?
  19. Replies
    17
    Views
    1,074

    OK, you will have a dead piece of equipment when...

    OK, you will have a dead piece of equipment when winter comes.

    The first time you turn on the gas heating, your secondary HX will be
    quickly filled with water and your pressure switch will kill...
  20. Replies
    17
    Views
    1,074

    No you have a five position unit!

    No you have a five position unit!
  21. Replies
    17
    Views
    1,074

    so is it a gas FURNACE or AHU? model # will help.

    so is it a gas FURNACE or AHU?
    model # will help.
  22. Replies
    17
    Views
    1,074

    the inside clearance between HX and cabinet is...

    the inside clearance between HX and cabinet is the smallest on the back. Also:
    if it's a 80eff, seriously dangerous venting issues in belly-up position, in fact, only
    a handful power-vented 80eff...
  23. Replies
    17
    Views
    1,074

    gas furnace can only be installed in horizontal...

    gas furnace can only be installed in horizontal positions with either of its SIDES on the bottom, if that unit is allowed horizontal installation at all.
  24. Replies
    20
    Views
    2,301

    no wonder...

    no wonder...
  25. Replies
    20
    Views
    2,301

    how do you know it was DIY? some so-called...

    how do you know it was DIY? some so-called contractors are no better than DIYers.
  26. Replies
    20
    Views
    2,301

    can't believe it's a goodman again, did you hire...

    can't believe it's a goodman again, did you hire a reputable contractor to install it or it was an internet purchase?
  27. Replies
    20
    Views
    2,301

    2 of your distributor feeders may be restricted...

    2 of your distributor feeders may be restricted and yes, low charge may cause some of the circuits to get less refrigerant than others too. You will need an experienced tech.
  28. Replies
    17
    Views
    1,408

    Even with 410a, temp glides are not too deviated....

    Even with 410a, temp glides are not too deviated. I remember once read that some factory test reports said that even if 50% of 410a leaks out, the remaining is still good blend of 410a.
  29. Replies
    4
    Views
    1,438

    you wont get good answers unless you have a "pro"...

    you wont get good answers unless you have a "pro" status.
  30. Replies
    17
    Views
    1,408

    Most techs do that, but if you are not sure,...

    Most techs do that, but if you are not sure, Diversitech makes an orifice device that goes on the suction service port. For R22, why not just use the vapor phase from the tank, maybe slow, but it...
  31. Replies
    21
    Views
    2,704

    does oil boil at all at 250 micron?

    does oil boil at all at 250 micron?
  32. Replies
    14
    Views
    1,123

    and ...?

    and ...?
  33. Replies
    9
    Views
    726

    don't know whether OP's 9.9c rate is just the...

    don't know whether OP's 9.9c rate is just the generation charge (PECO's rate to compare),
    there are also distribution/transmission/transitions charges that could add up to another 7-8 cents per kwh....
  34. Replies
    9
    Views
    726

    I am in Philly suburbs, some cheap developers...

    I am in Philly suburbs, some cheap developers here never bother to pay PECO to tap the street to its gas mains. So the only choice is all electric. I am not saying HP in PA is the most desirable...
  35. Replies
    9
    Views
    726

    The common wisdom is that when you can avoid oil,...

    The common wisdom is that when you can avoid oil, do it.
  36. Replies
    14
    Views
    1,123

    If the replacement air handler was from fresh...

    If the replacement air handler was from fresh stock 2 years ago, chances are it is rated for both 22 and 410a. Check its label. However, if you want the rated efficiency and good performance, a...
  37. Replies
    18
    Views
    2,202

    You should call them back and insist on a refund...

    You should call them back and insist on a refund of the 2nd $60 charge and demand a good repair. with new parts replacement, we guarantee that parts and labor for 6 months.
  38. Replies
    18
    Views
    2,202

    I hate to question the techs' competency, but did...

    I hate to question the techs' competency, but did he check the *** switches, *** motor and/or fetch error codes? Your chance of having several bad gas valves is quite slim. If you didn't see him use...
  39. Replies
    6
    Views
    718

    Goodman has a service bulletin on this particular...

    Goodman has a service bulletin on this particular issue, 2t-2.5t HPs. The remedy is to relocate the defrost temp-rise cutoff sensor to a lower position. Go to your supply house to look it up.
  40. Replies
    21
    Views
    2,004

    use green scotch pad

    use green scotch pad
  41. Replies
    4
    Views
    793

    Goodman bulletin SR-045 is about incomplete...

    Goodman bulletin SR-045 is about incomplete defrost problem on GSZ13 2ton and 2.5ton. But I guess your problem is more about bottom pan drainage.
  42. internal relief?

    internal relief?
  43. SR-036 and SR-041. You can search for old...

    SR-036 and SR-041. You can search for old discussion
    threads in this forum.
  44. There's a Goodman recall on this, that might be...

    There's a Goodman recall on this, that might be it.
  45. Replies
    13
    Views
    923

    a faulty propane meater?

    a faulty propane meater?
  46. Replies
    5
    Views
    2,219

    You can certainly try to do it, but if you don't...

    You can certainly try to do it, but if you don't have the system wired 100% correctly, at least it will bring you a high util bill and/or, worst yet, some equipment damage. I don't think you will get...
  47. Thread: no heat

    by seanddd
    Replies
    5
    Views
    500

    It would be helpful to know the model numbers,...

    It would be helpful to know the model numbers, IDT and ODT. I suppose 62psi is the suction? Also does the aux turn on?
  48. Replies
    12
    Views
    1,254

    Contractors have a lot of overhead costs. but to...

    Contractors have a lot of overhead costs. but to quote that price for a 2-ton HP is not smart, to say the least. However, it also depends on the actual property layout and location. Try fetch another...
  49. Replies
    12
    Views
    1,254

    A little bit steep for a 2ton, but pricing is not...

    A little bit steep for a 2ton, but pricing is not allowed in the forum. so edit it before the cops do it for you.
  50. Replies
    50
    Views
    4,704

    Where we are at, elec is 0.089 per KWH, but...

    Where we are at, elec is 0.089 per KWH, but that's only generation charge, there are also distribution and transition, another 0.08/kwh, so price is 0.17/kwh x1.9