  1. Replies
    15
    Views
    7,410

    Is your head Pressure than it Should be In Hot...

    Is your head Pressure than it Should be In Hot Weather?
    I am in Texas and If you have a unit on the roof with 105 Degree ambient and 112 Degree heat index Due to Humidity Then It will Run Very Hot...
  2. Replies
    9
    Views
    3,135

    AN Electric Valve?

    DO you mean the Pump Down Solenoid? Also if you Low pressure Cut out is set right it would not run In an 18 inch vacuum
  3. Replies
    14
    Views
    1,597

    Oh sorry forgot about the Product flowing into...

    Oh sorry forgot about the Product flowing into condenser make sure the drip tray is installed it is a long black tray that slides into a slot in the side that catches any overflow from the back...
  4. Replies
    14
    Views
    1,597

    Each Night at the Machine Should be broke Down...

    Each Night at the Machine Should be broke Down and sanitized with Taylor Sanitizer or you can use bleach and water they recommend Of course you use the powder Sanitzer that you mix with water ...
  5. Replies
    10
    Views
    1,148

    mallory timers

    There is a universal timer made by supco that has and adjustment on the defrost times that i use in every 115v application I run across that has the mallory type timers
  6. Thread: r-414

    by skunky
    Replies
    71
    Views
    14,855

    414

    I have not had any problem with 414 On some of the older systems you cant clear the sight glass I just charge the system by amp draw on the Compressor but make sure the box is warm when you start and...
  7. Thread: coil temps

    by skunky
    Replies
    6
    Views
    907

    do you mean saturation temp or Delta T across...

    do you mean saturation temp or Delta T across coils?
  8. Replies
    2
    Views
    717

    taylor

    are you having the same problems with both cylinders?
  9. Replies
    18
    Views
    2,933

    If you are just needing the door gasket then just...

    If you are just needing the door gasket then just get a sample from one corner measure the gasket and you can order from RHS catalogue
  10. Replies
    18
    Views
    2,933

    door parts

    check the brand of doors you have the most likely are made by anthony
    but should have model tag up on door frame either in front of back behind the frame that you can see from inside the cooler
  11. Replies
    18
    Views
    2,933

    Snyder general

    Snyder General products were manufactured By a ICP or Indoor Comfort products Same Company that made Arco aire and Temp star Equipment find A local dealer for Arco aire and they may be able to help...
  12. Replies
    9
    Views
    1,772

    Line tap

    If you are wanting to pierce the line to recover the refrigerant they make a tool that is a pair of vise grips with a piercing port on it that will pierce the line when you squeeze them on the line...
  13. That is a common situation people who know...

    That is a common situation people who know Nothing about Air Conditioning or refrigeration always think it is low refrigerant charge then are shocked when you tell them it is something else
  14. Replies
    48
    Views
    3,866

    If water was running when machine was not running...

    If water was running when machine was not running then Float valve is stuck open but that would have been evident when you first looked at the machine
  15. i hate 409a never use it any more I have found...

    i hate 409a never use it any more I have found that hot shot 414b works much better plus youdont have to mess with the polyester oil with the hotshot
  16. Replies
    21
    Views
    2,190

    get the box as hot as you can run thru derost and...

    get the box as hot as you can run thru derost and open doors then set the cpr valve by amp draw and set it within ten % of run load amps and it should be fine
  17. Replies
    23
    Views
    2,135

    If you are trying to cool your pc they have water...

    If you are trying to cool your pc they have water coolers that work great out on the market now check into that it has a closed loop water circuit with a tower that has radiator type of coil with a...
  18. Replies
    10
    Views
    1,209

    cheaper to buy a flaker and install than do that...

    cheaper to buy a flaker and install than do that voght ice machines make ice grinder that the cubes fall into after harvesting but i dont think hoshi has anything like that
  19. Thread: Scottsman

    by skunky
    Replies
    20
    Views
    2,185

    I have seen that in a lot of ice machines but not...

    I have seen that in a lot of ice machines but not that new of a machine it should be under warranty and i would just replace the evaporator sometimes if someone used non nickel safe ice cleaner in...
  20. Replies
    103
    Views
    12,437

    We dont do any maintenances after 5 pm due to the...

    We dont do any maintenances after 5 pm due to the overtime rates the customer is not going to pay overtime for it and we dont pay any of our techs overtime unless it is a paying overtime call unless...
  21. Replies
    103
    Views
    12,437

    Yep been there and done that are the maintenances...

    Yep been there and done that are the maintenances they are giving you mostly residential? If so it sounds like you work for a telemarketing company if that is the case get out fast!!! there are way...