Search:

Type: Posts; User: shaworth1

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds.

  1. Replies
    6
    Views
    666

    to many unknowns a manual j is needed.

    to many unknowns a manual j is needed.
  2. G5 twin great machine.

    G5 twin great machine.
  3. Replies
    3
    Views
    308

    Thanks a lot rundawg, that's exactly what I...

    Thanks a lot rundawg, that's exactly what I needed. Thanks for sharing.
  4. Replies
    3
    Views
    308

    Adding pipe to system looking for info.

    Working on a york rtu and have to add about 4 feet to a 1 5/8 line and also 4 feet to a 7/8 line and the system has a hot gas line which also needs 4 feet added to it. It is 1 3/8. system is r22. ...
  5. Thread: Tools

    by shaworth1
    Replies
    2
    Views
    417

    Just got mastercool hydraulic flaring and swaging...

    Just got mastercool hydraulic flaring and swaging kit. So far its a great tool.

    Sent from my MB886 using Tapatalk 2
  6. Replies
    7
    Views
    565

    Just had the exact thing happen tried to clean...

    Just had the exact thing happen tried to clean and resolder at valve no luck. Cleaned joint best i could and pulled out torch and brazed over the the old. Used the 15 and it flowed pretty good.
  7. Replies
    19
    Views
    1,224

    Had it done about 7-8 yrs ago. Best money I ever...

    Had it done about 7-8 yrs ago. Best money I ever spent, awesome not wearing glasses.
  8. Replies
    12
    Views
    1,075

    We have them were i work also when we were in...

    We have them were i work also when we were in punta cana they have then at there airport, work very well

    Sent from my MB886 using Tapatalk 2
  9. Replies
    38
    Views
    3,942

    Tif 9010a very durable, havent had any problems...

    Tif 9010a very durable, havent had any problems with it.

    Sent from my MB886 using Tapatalk 2
  10. Replies
    25
    Views
    1,631

    I really like the fieldpeice hs36.

    I really like the fieldpeice hs36.
  11. Replies
    12
    Views
    2,340

    Picked up a NRP 3cfm two stage vacuum pump at...

    Picked up a NRP 3cfm two stage vacuum pump at local aution house for $35. They were trying to sell it as an air compressor. Got it home works great!
  12. Replies
    135
    Views
    15,212

    hay zxcb what about the greedy CEOs and upper...

    hay zxcb what about the greedy CEOs and upper management, you think they would take a eight percent cut in their pay.
  13. Replies
    32
    Views
    3,250

    restneversleeps you mentioned about not sure how...

    restneversleeps you mentioned about not sure how to calculate ohms this is a good place to start.
    Ohm between R and C: This reading should be the lowest reading of the three readings. This is the...
  14. Replies
    18
    Views
    2,774

    is this app hvac buddy load calc. I was...

    is this app hvac buddy load calc. I was searching for it.
  15. Thread: Disconect

    by shaworth1
    Replies
    26
    Views
    3,041

    always replace a suspected faulty disconnect,...

    always replace a suspected faulty disconnect, there not that expensive and the homeowner deserves as safe a system as possible.
  16. Replies
    36
    Views
    3,780

    I like my C&Ds seem to be good quality.

    I like my C&Ds seem to be good quality.
  17. Replies
    4
    Views
    495

    mistype air temp at top was 70

    mistype air temp at top was 70
  18. Replies
    4
    Views
    495

    heat pump help

    got called to customers house not cooling complaint. Thermostat set at 72 inside temp of 82. Unit is a rudd heat pump with a 2.5 tom outdoor unit and 3 ton coil, with strip heat. got 80 psi on low...
  19. It should be good practice to verify the...

    It should be good practice to verify the information or not yourself. A visual inspection is always good anyway.
  20. Replies
    9
    Views
    788

    said you checked breaker visually, how about...

    said you checked breaker visually, how about checking the lugs of the breaker to make sure wires are tight in the lugs, I had one with a loose wire on lug and would trip breaker every once in a while.
  21. Replies
    16
    Views
    3,868

    I never turn my unit off in a thunderstorm unless...

    I never turn my unit off in a thunderstorm unless power starts to flicker on and off.
  22. just sounds like hes old school, continue doing...

    just sounds like hes old school, continue doing superheat and subcooling.
  23. Replies
    19
    Views
    3,484

    Check to see what the circuit is pulling now and...

    Check to see what the circuit is pulling now and what the circuit is rated for, should lead you in a good direction.
  24. Replies
    18
    Views
    4,808

    The pump im wondering about is a JB DV200N. It...

    The pump im wondering about is a JB DV200N. It is a 2 stage pump and does have an isolation valve. The reason im asking is i get a pretty good discount with grainger and they can give me a good...
  25. Replies
    6
    Views
    1,070

    epatest.com has a download for studying for the...

    epatest.com has a download for studying for the test. The test is not that hard, the hardest for me was all the dates to keep track of. Good luck!
Results 1 to 25 of 56
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event