  1. multi t stats

    what kind of t stats are they, first you can have multi, a voting takes place,
    theirs has to be a main controller like honeywell mm3, multi zone t stat.:) start looking, tracing out t stat wires to...
  2. Replies
    32
    Views
    10,476

    stop your whining, make a call, and have some...

    stop your whining, make a call, and have some faith in who ever comes out, without you trying to find a bullet for the tech that come out, otherwise go sign up for an hvac class. your one more...
  3. Replies
    16
    Views
    1,590

    san antony

    pull refrigerant out, cut line and blow high pressure nitogen back pressure both way, put a rag on opposite line to catch debris hopefully. change the drier, vacuum, fresh refigerant, clean...
  4. Replies
    7
    Views
    2,217

    underground line set help!!!!

    what is the proper way to run a line set underground and is conduit ok
  5. underground line set, help

    what is the proper way to run a line set underground and is conduit ok :)
  6. Replies
    16
    Views
    10,992

    ive done it, let it set 24 hrs then start it...

    ive done it, let it set 24 hrs then start it up..ive never had a problem.
  7. Replies
    10
    Views
    1,306

    engery star

    dont you mean that the vent pipe goes after the trap and not before, so it will drain. from the unit unit and leaving it ,drainline,peetrap,tee with stand-off pipe. otherwise your right..it all...
  8. Replies
    9
    Views
    1,739

    sounds like bad vales to me 100# suction, wow ....

    sounds like bad vales to me 100# suction, wow . whats the outside air, and return temp. replace the system.....
  9. Replies
    17
    Views
    1,586

    measure sh/sc install time off delay and put on...

    measure sh/sc install time off delay and put on the electronic tattle tales.why is it tripping night time seems like a low ambient condition my friend....:)
  10. Replies
    22
    Views
    2,674

    sight glass

    ok some of you have it right!! like after the liquid line drier, the subcooling backs up into the condenser. not the other way!. and there only one way to measure subcooling is with a gauge and a...
  11. Thread: Fla

    by blackbird
    Replies
    11
    Views
    1,243

    stay away from adjusting for rla, when design...

    stay away from adjusting for rla, when design conditions are meet, like a properly charge compressor circuit your not looking always at fla to be meet, this is asking for trouble.... and usally 3...
  12. Replies
    5
    Views
    545

    your system is r-22 with age like that, your...

    your system is r-22 with age like that, your pressure is low, with a 92 degree ambient, check your sub cool, and super heat, check static pressure for low air flow, and leak check before you remove...
  13. i agree with mark, also if the compressor...

    i agree with mark, also if the compressor started, and it didn't need any help stating, its probably is ok, plus you still have 5 more years on the 10 year warranty to find out.:cool:
  14. Replies
    19
    Views
    1,258

    it could be the new higher seer rating, may not...

    it could be the new higher seer rating, may not be removing the mositure that the old 10 seer did. you may need to lower the tstat a couple of degrees than you did before , and run the fan on a...
  15. call him back, or get a second just to be sure...

    call him back, or get a second just to be sure...
  16. Replies
    15
    Views
    1,829

    spiral ductwork

    hey thanks to all, i got some good advice.
  17. Replies
    15
    Views
    1,829

    spiral ductwork help

    anyone have any tips on cutting spiral duct work so it looks good.
  18. Replies
    2
    Views
    632

    a liitle help form the pros thxs

    a liitle help form the pros thxs
  19. Replies
    2
    Views
    632

    evaporator coil efficiency

    #1 is a 3 ton evaporator coil, still 3 ton regardless if you install a higher efficiency condenser coil..

    #2 txv is needed, and if its a cap tube, its gone regardless? if you have a fixed...
  20. Replies
    17
    Views
    2,221

    older tech, yes i get it. iam not sweating it...

    older tech, yes i get it. iam not sweating it anymore, learn a valuable lesson..i like your saying in your profile, fix it right the first time.. thats all.. taking what i learn here to a higher...
  21. Replies
    17
    Views
    2,221

    oh yes you have misunderstood me, iam the 3rd man...

    oh yes you have misunderstood me, iam the 3rd man 3rd company out there , they informed me of the original contractor who did the install. the second contractor was clearing the restriction, i...
  22. Replies
    17
    Views
    2,221

    hey thanks for all the replies, ill tell you...

    hey thanks for all the replies, ill tell you this, i appreciated this site, I'm still learning, like AL Pacino said in sent of a women.... Ive been around whoahhh!!
    but seriously ill handle it...
  23. Replies
    17
    Views
    2,221

    its not a lemon, and yes it is a carrier, and he...

    its not a lemon, and yes it is a carrier, and he finally put a drier in i only hear that he did, and i watched him put a hard start on the one previous, and i don't think he used a drier, i can...
  24. Replies
    17
    Views
    2,221

    hard start kit

    let see if my college here can help me out..had a call over the weekend, found compressor not being able to start, lock rotor amps on compressor, then going out on internal overload.. fixed office,...
  25. Replies
    24
    Views
    4,011

    lack of

    Is losing 2lbs of freon over 5 years a lot? What if I don't fix the leak?

    just this statement alone calls for a pro with experience. dont insults the intergity of experience