10-13-2005, 03:08 PM
Thread: New Furnace Savings & Dealer Advice
by joebrisbin- Replies
- 5
- Views
- 825
Dilbert, Your current unit is 100kBTU and 60%...
Dilbert,
Your current unit is 100kBTU and 60% so you are getting approximately 60kBTU out of the existing unit.
If you upgrade to a 90% then you will be increasing your current efficiency by... -
10-10-2005, 02:53 PM
Thread: Dirty Coil > DSS ???
by joebrisbin- Replies
- 13
- Views
- 1,550
For me and the other non HVAC folk, What is DSS...
For me and the other non HVAC folk,
What is DSS ?
Thank you. -
10-10-2005, 01:41 AM
Thread: no nitrogen flow while brazing?
by joebrisbin- Replies
- 200
- Views
- 11,081
NormChris, Here is the instructions to post...
NormChris,
Here is the instructions to post pictures on this web site
just follow this link:
http://www.hvac-talk.com/vbb/showthread.php?threadid=22507
We are all looking forward to see them!... -
10-09-2005, 02:10 PM
Thread: no nitrogen flow while brazing?
by joebrisbin- Replies
- 200
- Views
- 11,081
Man, the smoke is now clearing. It is obvious...
Man, the smoke is now clearing. It is obvious that nitro purge is required by many manufacturers including Trane.
Yes I want my new AC and heater to last a long time!!
My wife asked one of the... -
10-07-2005, 04:20 PM
Thread: no nitrogen flow while brazing?
by joebrisbin- Replies
- 200
- Views
- 11,081
They added one collar joint in the lines where...
They added one collar joint in the lines where they come up through the floor. So there are 4 joints on each line, one at each end and 2 for the collar.
I think a liquid line dryer comes already... -
10-07-2005, 02:27 PM
Thread: no nitrogen flow while brazing?
by joebrisbin- Replies
- 200
- Views
- 11,081
Thanks Coolwhip,
I know I will be fine. But how...
Thanks Coolwhip,
I know I will be fine. But how about the equipment?
Just kidding... Thanks for the reply. -
10-07-2005, 02:26 PM
Thread: no nitrogen flow while brazing?
by joebrisbin- Replies
- 200
- Views
- 11,081
Thanks Irascible, The rods they used came out...
Thanks Irascible,
The rods they used came out of a plastic tube.
The rods looked like stiff solder. So maybe they actually soldered and did not braze after all.
Now that you mention it, they... -
10-07-2005, 01:51 PM
Thread: no nitrogen flow while brazing?
by joebrisbin- Replies
- 200
- Views
- 11,081
I saw in several posts about flowing nitrogen...
I saw in several posts about flowing nitrogen while brazing.
My Trane 19i was installed last week and I did not see either of the installers using nitrogen when they were brazing.
I think that this... -
10-04-2005, 01:18 PM
Thread: Duct misalignment question
by joebrisbin- Replies
- 11
- Views
- 832
You are right. I don't need to know how to...
You are right. I don't need to know how to measure the ESP but I want to make sure the installer measures it. My wife is at the install site and not me.
This is at her folks house and the three of... -
10-04-2005, 12:51 PM
Thread: Duct misalignment question
by joebrisbin- Replies
- 11
- Views
- 832
These ducts are in the attic. The roof slopes...
These ducts are in the attic. The roof slopes down and there is not much working space where the top of the AC coil at 93 1/2 inches off the floor.
My wife is at the house with the installer right... -
10-04-2005, 12:41 PM
Thread: Duct misalignment question
by joebrisbin- Replies
- 11
- Views
- 832
The secretary of the installers did not know what...
The secretary of the installers did not know what I meant by a fan chart.
Is this fan chart the one that is in the installation manual or is this some diagnostic chart that the installers have... -
10-03-2005, 06:49 PM
Thread: Duct misalignment question
by joebrisbin- Replies
- 11
- Views
- 832
Thanks Dash, I really appreciate your reply....
Thanks Dash,
I really appreciate your reply.
I will ask them for what you suggest.
It sounds like you completely understood my convoluted question!!!
THANK YOU!! -
10-03-2005, 04:55 PM
Thread: Duct misalignment question
by joebrisbin- Replies
- 11
- Views
- 832
My parents furnace and AC install was started...
My parents furnace and AC install was started last week and will be finished tomorrow (connect the freon lines and install the roof vent pipes). It took longer than the installers planned because the...
-
09-30-2005, 12:31 PM
Thread: 90% Furnace Negatives
by joebrisbin- Replies
- 22
- Views
- 2,058
Amickracing... To make the venting simple, how...
Amickracing...
To make the venting simple, how about using a concentric vent. This is only one vent hole in the roof with 2 PVCs one inside the other. This is what I am having installed in a... -
09-21-2005, 07:52 PM
Thread: 19i near wall
by joebrisbin- Replies
- 4
- Views
- 490
Yes. That's it. My wife and I both spoke to Trane...
Yes. That's it. My wife and I both spoke to Trane reps and we were told: Putting a 19i 8 inches from the wall is not a problem and there will be no noticable change in SEER. But one of them also...
-
09-21-2005, 02:20 AM
Thread: 19i near wall
by joebrisbin- Replies
- 4
- Views
- 490
I am having a Trane 19i 4 ton AC installed at the...
I am having a Trane 19i 4 ton AC installed at the south side of my in-laws house. The system will also have a Trane 100kBTU XV90 and a 5inch media filter. The model of the coil is hard to read on...
-
09-19-2005, 12:19 AM
Thread: Trane XV90 combustion air
by joebrisbin- Replies
- 11
- Views
- 1,102
Thanks Jeep,
I will make sure he puts the pipe...
Thanks Jeep,
I will make sure he puts the pipe in the existing roof vent hole instead of through the wall where the dryer vents.
Thanks for the inputs.
JB -
09-18-2005, 12:13 AM
Thread: Trane XV90 combustion air
by joebrisbin- Replies
- 11
- Views
- 1,102
I searched the web for "concentric vent" and...
I searched the web for "concentric vent" and found a couple of different styles. One was a box that COMBINED both pipes into one common pipe (not a wise choice). The other looked good, one pipe...
-
09-17-2005, 10:28 PM
Thread: Trane XV90 combustion air
by joebrisbin- Replies
- 11
- Views
- 1,102
Thanks guys. I will ask my installer for a...
Thanks guys. I will ask my installer for a concentric kit.
The comments about do not use laundry room air make a lot of sense! We want this unit to last a long time.
THANKS FOR ALL THE ADVISE!!! We... -
09-17-2005, 03:18 PM
Thread: Trane XV90 combustion air
by joebrisbin- Replies
- 11
- Views
- 1,102
I am not familiar with a concentric kit. Does...
I am not familiar with a concentric kit. Does that mean having two PVC pipes going through one flue hole in the roof?
-
09-17-2005, 03:06 PM
Thread: Trane XV90 combustion air
by joebrisbin- Replies
- 11
- Views
- 1,102
The house is in Lafayette, CA. It is single story...
The house is in Lafayette, CA. It is single story about 2200 sq ft, 50 years old with alot of windows (thin single pane) and no wall insullation.
The existing furnace is 135 intake / 108 output.... -
09-17-2005, 02:31 PM
Thread: Trane XV90 combustion air
by joebrisbin- Replies
- 11
- Views
- 1,102
I am having a Trane XV90 TUY100R9V4W installed to...
I am having a Trane XV90 TUY100R9V4W installed to replace an old gas furnace at my mother-in-laws house. The new furnace will be installed in an un-airconditioned laundry room at one end of the...