Search:

Type: Posts; User: dman1

Search: Search took 0.00 seconds.

  1. Thread: boom

    by dman1
    Replies
    8
    Views
    944

    Got a call today rtu not running.Checked voltages...

    Got a call today rtu not running.Checked voltages out and found 3 amp fuse control circuit fuse blown.replaced fuse and fuse blow again.Pushed contactor for compressor in manually to listen to...
  2. Thread: chiller

    by dman1
    Replies
    1
    Views
    575

    Had to do a start up on a chiller and found that...

    Had to do a start up on a chiller and found that the contractor used to shut down the chiller last year took out all of the control circuit fuses (8) disconnected the outdoor sensor on the terminal...
  3. Replies
    6
    Views
    1,145

    t stat wiring

    It may not matter but you know the standard 4 or 5 are the same 99 percent of the time.Ant mechanic can go to the cs terminal block to figure out the wiring but lets face it,as I stated my post was...
  4. Replies
    6
    Views
    1,145

    posted this on residential but more of a...

    posted this on residential but more of a commercial problem.I am finding that the blue and orange control circuit wires are constantly being swapped for second stage cooling and heating.wondering if...
  5. Replies
    3
    Views
    833

    I have noticed that on quite a few thermostats...

    I have noticed that on quite a few thermostats that there has been second stage cooling sometimes is using the blue wire and sometimes an orange wire and the same goes for second stage heat.Talked to...
  6. Thread: r-134

    by dman1
    Replies
    4
    Views
    778

    does anyone know if the tool that i use to remove...

    does anyone know if the tool that i use to remove schrader valves for 1/4 fittings can be used for auto r-143 fittings if I remove the quick disconnect or is there a special tool for auto. this is...
  7. Thread: cold air returns

    by dman1
    Replies
    2
    Views
    829

    can anyone site me from the code all the places...

    can anyone site me from the code all the places cold air returns arent allowed. I know the kitchen is one how about the others
  8. Replies
    20
    Views
    6,899

    hot surface ignition

    doc what year did the rheem start using the spark ignition?I have a ten year old rheem with hsi
  9. Replies
    8
    Views
    1,216

    firestat

    roc I had a feeling it might be a firestat but trust me I looked for a reset until the cows came home.My biggest concern was that there were relays on the board, I wasnt sure if a relay was working...
  10. Replies
    8
    Views
    1,216

    24 volts

    i was stumped because i was getting 24 volts at the unit on the roof but couldnt jump it out at the thermostat even i was getting 24 volts at r on the therm.i couldnt jump out w or y at the therm but...
  11. Replies
    8
    Views
    1,216

    worked on a air handler yesterday and unit ran in...

    worked on a air handler yesterday and unit ran in heat mode when jumped out at the unit control circuit but not at the thermostat.Had power at the thermostat and jumped thr r and w terminals but no...
  12. Thread: thermostat

    by dman1
    Replies
    4
    Views
    851

    thermostat

    control tech you nailed it.When i got to work at 600am I had it working by 610.If i knew you i would by you a sixpack,but I dont so thanks
  13. Thread: thermostat

    by dman1
    Replies
    4
    Views
    851

    thermostat

    i have the fan code at 2-0 which according to the literature is fan operation only when theres a call for heat or cooling.Im going to double check though and i appreciate your time and info
  14. Thread: thermostat

    by dman1
    Replies
    4
    Views
    851

    installed a honeywell 3700d series 2000...

    installed a honeywell 3700d series 2000 thermostat on a rtu and I cant get the fan to stay on auto.Checked all the wiring ,ran the thermostat in test mode ,checked out,made sure the codes were...
  15. Thread: Economizers

    by dman1
    Replies
    17
    Views
    1,957

    economizer

    Stryder you beat me to the punch.people dont realize that these enthalpy boards last only a couple of years and then they get sticker shock when it comes time for replacement
  16. Thread: Reversing Valve

    by dman1
    Replies
    8
    Views
    4,879

    reversing valve

    it sounds like bad valves .just wondering do you hear the valve when it gets energized?
  17. Replies
    14
    Views
    3,946

    I understand the trane tru sense monitors are a...

    I understand the trane tru sense monitors are a pos.I remember alot of positive feedbach on the bacharach monitors.We're looking to replace our trane pos and wander if any feedback on these. thanks...
  18. Replies
    8
    Views
    1,110

    monitor

    these are filtered monitors from trane. tru sense monitor didnt have time today to check the floor drains but thats and interesting idea.thanks for taking the time to reply
  19. Replies
    8
    Views
    1,110

    anyone experience trouble with their refrigerant...

    anyone experience trouble with their refrigerant monitors constantly sending off alarms?had the company come out and change the filters and calibrate it but still keep getting false alarms like 1-6...
  20. Replies
    9
    Views
    1,143

    lock out

    just a guess but you might want to check the oat as well as the enthalpy control.the manual tells you that the enthalpy controls are expected to be changed every couple years. i agree with mardoman...
  21. Replies
    4
    Views
    1,020

    disposal

    i was responsible for removing the equipment. i just wanted a certification that the unit was either recovered or empty.i know even though i"m certified i cant tag it without a recovery unit...
  22. Replies
    4
    Views
    1,020

    hey guys help me out.i do hvac work for the usps...

    hey guys help me out.i do hvac work for the usps and on one job involved disposing of an air handler with 10 pounds of r-22.since they dont want to be bothered keeping records for refrigerant use and...
  23. Replies
    2
    Views
    794

    soft start

    yes, the square d literature says to check the thystors
  24. Replies
    2
    Views
    794

    has anyone have any experience troubleshooting...

    has anyone have any experience troubleshooting the altistart soft start motor starters from square d?seems if you put the disconncet off and on too fast the fault light comes on and its shot.did the...
  25. Thread: usps

    by dman1
    Replies
    8
    Views
    896

    usps jobs

    i"m a vet and i would only get preference on non skilled jobs.here in south jersey only 2 people passed the building equipment mechanic test.they want you to know welding, hvac,...
  26. Thread: usps

    by dman1
    Replies
    8
    Views
    896

    postal

    what jobs did you apply for and how do you know you aced the test?usually hiring consists of ksa book,the test and a review board
  27. Thread: usps

    by dman1
    Replies
    8
    Views
    896

    does anyone out there work in hvac for the postal...

    does anyone out there work in hvac for the postal service? I would like to discuss the different equipment being worked on
Results 1 to 27 of 36
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event