Search:

Type: Posts; User: dugfish

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Thread: What next?

    by dugfish
    Replies
    9
    Views
    794

    NATE would be a good start

    NATE would be a good start
  2. Replies
    17
    Views
    1,697

    Ive worked on Suburbans DL3 pretty nice units

    Ive worked on Suburbans DL3 pretty nice units
  3. Replies
    12
    Views
    1,068

    Did you pull the inducer and look at the choke...

    Did you pull the inducer and look at the choke disc.
  4. Thread: No heat

    by dugfish
    Replies
    7
    Views
    1,515

    sounds like power issue

    sounds like power issue
  5. Replies
    6
    Views
    820

    Infinity Air Purifier

    Infinity Air Purifier
  6. Replies
    12
    Views
    743

    You sure its not the gas valve

    You sure its not the gas valve
  7. Replies
    5
    Views
    487

    Get rid of the EAC and install a media type...

    Get rid of the EAC and install a media type filter great idea. Usually the blower wheel collects all the dust that the EAC doesnt get. Second does that room have enough return air going back to the...
  8. Heat pump in MN is like having a 95% eff furnace...

    Heat pump in MN is like having a 95% eff furnace on the equator.
  9. Replies
    47
    Views
    3,373

    You will love the system Comfort is top notch we...

    You will love the system Comfort is top notch we put in a bunch of these systems. Make sure everything is set right.
  10. Replies
    20
    Views
    5,014

    White Rodgers Big Blue Touchscreen best stat out.

    White Rodgers Big Blue Touchscreen best stat out.
  11. Replies
    19
    Views
    1,471

    You need more School

    You need more School
  12. Replies
    14
    Views
    1,065

    On the back of the stat there is a dip switch A/C...

    On the back of the stat there is a dip switch A/C or HP is that ok
  13. Replies
    13
    Views
    1,288

    Dont put in the 5 ton Wont dehumidify You house...

    Dont put in the 5 ton Wont dehumidify You house will get cold quick but you will think you are in the caves in kentucky.
  14. Replies
    14
    Views
    1,065

    Sounds like some kind of stat problem (Wiring...

    Sounds like some kind of stat problem (Wiring )check the switches in the stat What kind of stat brand name would help
  15. Replies
    19
    Views
    1,471

    Emergency heat is that you need it because the...

    Emergency heat is that you need it because the compressor is Dead!!!!!!!
  16. Replies
    3
    Views
    921

    Replace the furnace. See if it still has the...

    Replace the furnace. See if it still has the Fenwall ignition box on it. There is a upgrade for that. If it still has the orginal gas valve on it replace it too. Normally the the HE has a big...
  17. Doesnt matter go cheap you dont have a ECM blower...

    Doesnt matter go cheap you dont have a ECM blower motor.
  18. Replies
    4
    Views
    867

    Copeland Scroll Ultra Tech

    Copeland Scroll Ultra Tech
  19. Replies
    49
    Views
    7,781

    No one has tried a new pressure switch yet.

    No one has tried a new pressure switch yet.
  20. Very easy Infinity all the way!!!!!!!!!!!!

    Very easy Infinity all the way!!!!!!!!!!!!
  21. Replies
    13
    Views
    2,101

    Lick you right finger and see how fast it dries...

    Lick you right finger and see how fast it dries about 2 inches from the blade. 1 second cfm= fast 2 seconds cfm= medium 3 seconds cfm= slow
  22. Replies
    6
    Views
    873

    You better find out what size blower you have on...

    You better find out what size blower you have on the furnace. Its not going to matter what outdoor unit you have your going to have to much air blowing through the evaporator coil you will remove...
  23. Replies
    7
    Views
    908

    Go with the Copeland scroll it is 2 stage. Very...

    Go with the Copeland scroll it is 2 stage. Very relaible 10 yr warr.
  24. Replies
    17
    Views
    2,500

    Carrier Infinity is the best. Infinity stat, ECM...

    Carrier Infinity is the best. Infinity stat, ECM motor it the best thing out there right now. There might be a rebate and tax credit on this equipment.
  25. Replies
    358
    Views
    17,382

    Giving

    The new testament church Jesus said Go sell everything you have and follow me. I give a tenth and I thank God for the blessings he has blessed me with. If you invest in God he will invest in you...
  26. Replies
    32
    Views
    4,855

    Trane is the best.

    Trane is the best.
  27. Replies
    15
    Views
    4,330

    Kickstart best one out there.

    Kickstart best one out there.
  28. Thread: WATER LEAK

    by dugfish
    Replies
    5
    Views
    684

    Was unit freezing up so they installed a TXV. I...

    Was unit freezing up so they installed a TXV. I would have them put a wet switch in the secondary pan.
  29. Replies
    4
    Views
    993

    You dont need anything looks like you have a gas...

    You dont need anything looks like you have a gas furnace and a condensor looks like to me you need an installer.
  30. Replies
    18
    Views
    2,215

    All heat pumps should have hard start kits on...

    All heat pumps should have hard start kits on them thats what I think.
  31. Thread: Trane XV90

    by dugfish
    Replies
    6
    Views
    826

    That unit is so quiet most of the time I cant...

    That unit is so quiet most of the time I cant tell if its even running.
  32. Replies
    5
    Views
    907

    Check the capacitor.

    Check the capacitor.
  33. Thread: Lennox Pulse

    by dugfish
    Replies
    31
    Views
    3,119

    Is this furnace grounded back to the main panel?

    Is this furnace grounded back to the main panel?
  34. Replies
    11
    Views
    1,362

    Go with the XV90 2 stage with variable speed...

    Go with the XV90 2 stage with variable speed blower then add the Spacegard 5000 air cleaner. Awesome system! http://www.aprilaire.com
  35. You need to find the total external static...

    You need to find the total external static pressure on the system. Should be .50" in w.c. Start with the return side since your getting that message. Check it after the filter and before the blower...
  36. Replies
    9
    Views
    928

    Sounds like its cycling on the limit. Filter...

    Sounds like its cycling on the limit. Filter clean or do you have a round Honeywell thermostat?
  37. Maybe you needed a bigger blower for A/C thats...

    Maybe you needed a bigger blower for A/C thats all that i see same amount of heat 100000 btus.
  38. Have tech put hard start kit on it wont hurt...

    Have tech put hard start kit on it wont hurt anything easiest way to explain it is that it starts the motor quicker. If your coil has a non bleed TXV on it you will need the hard start kit.
  39. It does have a multi speed blower 3 ton blower...

    It does have a multi speed blower 3 ton blower this isnt the variable speed blower.
  40. Replies
    42
    Views
    3,756

    I would replace Inducer, ignitor, gas valve,...

    I would replace Inducer, ignitor, gas valve, blower motor, circuit board, burners, pressure switch, transformer, t-stat, chimney liner and hope for the best.
  41. Replies
    4
    Views
    803

    Does your system have a filter on it if it does...

    Does your system have a filter on it if it does then yeah it is filtering the air.
  42. Replies
    10
    Views
    1,068

    Are you sure you need a 5 ton unit? How big is...

    Are you sure you need a 5 ton unit? How big is your house?
  43. Go with the MVB Carrier is changing to Nitride...

    Go with the MVB Carrier is changing to Nitride Ignitors with the B in the Model number. MVP is Carbide Ignitor. Go with the Infinity Control with a 13 Seer 38TXA??? Best system on the market.
  44. Replies
    29
    Views
    3,117

    R410A you must braze. Higher pressures. Dont...

    R410A you must braze. Higher pressures. Dont solder
  45. Leak?

    Leak?
  46. Thread: pulsating line

    by dugfish
    Replies
    4
    Views
    931

    Make sure you dont have 1/4 inch line that is...

    Make sure you dont have 1/4 inch line that is stuffed into 3/8 line then going to the piston. i found flashing going from 1/4 to 3/8 before metering device. low suction high head high superheat.
  47. Replies
    13
    Views
    1,785

    Please tell me you are using a 58MVP and why...

    Please tell me you are using a 58MVP and why arent you using the infinity control stat. Your system probably aint designed for 2 stage. Must have variable speed blower with this condensor.
  48. Replies
    33
    Views
    3,600

    have you ever considered a whole house...

    have you ever considered a whole house dehumidifier Aprilaire makes the best one. Gets piped in the duct system with controls to set on humidity levels. You need to check fan speeds also i noticed...
  49. Replies
    26
    Views
    2,237

    what unit comes charged for a 50 foot line set...

    what unit comes charged for a 50 foot line set never heard of it usually around 15 to 20.
  50. Replies
    7
    Views
    848

    What is a recyler?

    What is a recyler?
Results 1 to 50 of 63
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event