Search:

Type: Posts; User: protechplumbing

Search: Search took 0.01 seconds.

  1. Checked vigorously for leaks during nitro...

    Checked vigorously for leaks during nitro pressure check and evacuation. No leaks, no doubts.
  2. I applied for pro. The system was under charged....

    I applied for pro. The system was under charged. It's working great now. As I said, I think I moved the hose when I zeroed the scale so it was reading low. I slowly added r-22 while checking...
  3. I got it dialed in now. It was low on charge. I...

    I got it dialed in now. It was low on charge. I must have moved the hose on the cylinder when I was zeroing the scale.
  4. I added refer. Sh currently 30

    I added refer. Sh currently 30
  5. 66.2 register 80.1 intake grill 72 wet bulb ...

    66.2 register
    80.1 intake grill
    72 wet bulb

    83.3 ambient
    89.3 condenser outlet

    67/190 psi

    piston metering device
  6. That takes several weeks. I'll have it figured...

    That takes several weeks. I'll have it figured out by then.
  7. I'm going back out there now I suspect the charge...

    I'm going back out there now I suspect the charge is some how low but I don't see how because I weighed the charge exactly. The line set is 25 feet long roughly and I weighed out the recommended 72...
  8. 2 ton r-22 split system freezing at suction line

    Customer called and said in the middle of the night the unit stopped cooling and the suction line was covered with ice at the heat pump all the way to the compressor.

    Heat pump was just replaced...
  9. The main issue with them liming up is that when...

    The main issue with them liming up is that when they draw water through a coaxial fitting at the bottom of the tank they picku sediment in the bottom of the tank. This sediment then clogs the...
  10. Replies
    7
    Views
    2,137

    I was referring to this link:...

    I was referring to this link: http://www.renewability.com/power_pipe/index.html

    Perhaps it is you who should be doing the thinking. Legionella will grow in potable water that is allowed to stand...
  11. Replies
    5
    Views
    1,861

    :spam:

    :spam:
  12. Replies
    13
    Views
    2,189

    I also here that propress isn't good for...

    I also here that propress isn't good for application that are subject to constant vibrations. A voper compression system seems like the worst place to try to use propress.
  13. Replies
    13
    Views
    2,189

    I wouldn't think it could handle the pressures...

    I wouldn't think it could handle the pressures and temps in a 410A system.
  14. Replies
    29
    Views
    8,095

    Thanks for the info.

    Thanks for the info.
  15. Replies
    13
    Views
    2,189

    It would be faster but the material would be more...

    It would be faster but the material would be more than threading BI.
  16. Replies
    13
    Views
    2,189

    To be clear, you won't see cavitation in gas...

    To be clear, you won't see cavitation in gas lines, only water lines.

    I have seen cavitation in copper pipes due to not reaming cuts made by copper cutters. That will happen no matter what kind of...
  17. Replies
    29
    Views
    8,095

    Should I be looking at an open loop pump and dump...

    Should I be looking at an open loop pump and dump instead of closed loop?
    I can always replace the coil if it gets fouled. My only concern is energy efficiency. I can punch 2 holes in the ground...
  18. Replies
    13
    Views
    2,189

    At high water velocities if there are any...

    At high water velocities if there are any imperfections in the pipe wall cavitation will occur just behind the obstruction.
  19. Replies
    7
    Views
    963

    uhhh, what? water expands when heated not cooled.

    uhhh, what? water expands when heated not cooled.
  20. Replies
    13
    Views
    2,189

    What do you have against propress for gas? I...

    What do you have against propress for gas? I wouldn't trust it for potable water lines due to chemical attack and cavitation, but gas? Sure.
  21. Replies
    7
    Views
    963

    bad expansion tank?

    bad expansion tank?
  22. The best thing to do is buy a larger solar tank....

    The best thing to do is buy a larger solar tank. Look for tanks designed for open loop solar applications. They will have 5 ports on the top and 3 dip tubes. You usually get more mileage out of a...
  23. Replies
    29
    Views
    8,095

    sorry, i forgot about the price thing.

    sorry, i forgot about the price thing.
  24. Replies
    29
    Views
    8,095

    At 300' bore per ton, I would be looking at 1200'...

    At 300' bore per ton, I would be looking at 1200' feet total for a new 4 ton geo system. I'm not sure going geo would be an economically sound decision in my situation. I would estimate that the...
  25. If sized properly a single tank is just fine. You...

    If sized properly a single tank is just fine. You simply disconnect the lower element and leave the upper one attached. The upper element will only fire when you are about to run out of heat...
  26. Replies
    47
    Views
    3,405

    I use my fluke 116 more than anything else. I use...

    I use my fluke 116 more than anything else. I use my Fluke T5 for inductive amp reading. The T5 looks like crap but it works just fine. It's been rained on and dropped into water several times as...
  27. You are referring to what's known as a "coaxial...

    You are referring to what's known as a "coaxial fitting". As hvacguy said, if you have very hard water in your area they will get clogged up easily.
  28. Replies
    29
    Views
    8,095

    Hey down2earthgeo, how about florida? zip code...

    Hey down2earthgeo, how about florida? zip code 33881? What say you?
  29. Replies
    7
    Views
    2,137

    The plumber won't touch it because it's a haven...

    The plumber won't touch it because it's a haven for Legionella growth.
  30. Replies
    100
    Views
    5,906

    A neon light transformer. I was leaning over a...

    A neon light transformer. I was leaning over a rail and the current wen’t into my hand and out of my stomach where it touched the rail. I had a 4" long horizontal burn across my belly 1" below my...
  31. Replies
    6
    Views
    588

    Good advice.

    Good advice.
  32. Replies
    16
    Views
    1,142

    I use a fine toothed sawzall blade.

    I use a fine toothed sawzall blade.
  33. Replies
    100
    Views
    5,906

    I've been hit with over...

    I've been hit with over 2000Volts...........Twice. The jolt it self knocked me out. What hurt is when I woke up to a burning sensation and smelling burnt meat only to realize it was my own skin I was...
  34. I’ve got a 10 year old 4 ton heat pump (york). I...

    I’ve got a 10 year old 4 ton heat pump (york). I have no complaints. Gas is not an option because the line that runs down my street stops 4 lots from my house. It frosts up even in central Florida’s...
  35. Replies
    9
    Views
    765

    Couldn’t one just plug the lower end of the line...

    Couldn’t one just plug the lower end of the line set and fill them up with acetone and after draining, blow them out with nitrogen? I wouldn’t think anything would remain in the lines after that.
  36. Replies
    18
    Views
    1,284

    Vertical bores don't take up too much room.

    Vertical bores don't take up too much room.
  37. Replies
    18
    Views
    1,284

    I'm no expert, but if electricty is that...

    I'm no expert, but if electricty is that expensive why not go geothermal heat pump?
  38. Replies
    25
    Views
    4,923

    SSX34

    SSX34
  39. Replies
    25
    Views
    4,923

    I know, but time is money and I like to be lazy...

    I know, but time is money and I like to be lazy and let the instrements do the thinking. I do think one should have the ability to "rough it" in case his fancy meters fail though.
  40. Replies
    25
    Views
    4,923

    superheat/subcool meter

    Hello all.

    I was wondering what everyone thinks of the superheat/subcool meter by fieldpiece?