Search:

Type: Posts; User: njguy99

Search: Search took 0.00 seconds.

  1. Replies
    9
    Views
    855

    Based on some of the responses here, I just...

    Based on some of the responses here, I just called around and asked about variable speed.

    The Goodman salesman offered me the GMV95 (90,000 btu) furnace instead, with the CLQ (36,000 btu) air...
  2. Replies
    9
    Views
    855

    BaldLoonie - They all did measurements, but I...

    BaldLoonie -
    They all did measurements, but I have yet to see an actual "caclulation" per se.

    Is there any simple way for me to do a load caclulation myself?

    I do like the Bryant unit - and...
  3. Replies
    9
    Views
    855

    cem-bsee: I just bought the house, so I have...

    cem-bsee:

    I just bought the house, so I have no idea if it was comfortable or not or how much fuel they used. I also have no idea how to do a load calculation.

    The existing furnace is shot,...
  4. Replies
    9
    Views
    855

    Hi everyone - Just bought an older home, and...

    Hi everyone -

    Just bought an older home, and the time has come to replace the circa-1966 American Standard forced-air gas furnace. The previous owners never added central AC, so we're doing that...
  5. Replies
    7
    Views
    1,126

    Well...you guys were right. They cut the ductwork...

    Well...you guys were right. They cut the ductwork open, and, in the words of the tech who was looking at it, the coil was "filthy." Even to my naked eye it looked dirty - covered with muck and grime,...
  6. Replies
    7
    Views
    1,126

    Thanks guys. I'm having someone come take a look...

    Thanks guys. I'm having someone come take a look at the machine today - so I'm gonna ask him about the coils.

    One question: is it easy to clean them? Mine are behind the ductwork, so I imagine...
  7. Replies
    7
    Views
    1,126

    Thanks Doc - but the system doesn't have any...

    Thanks Doc - but the system doesn't have any dampers. The more I look at it, the more it seems like air is escaping from below the flue and traveling right out the top of the furnace.

    The air...
  8. Replies
    7
    Views
    1,126

    I've been hunting around the forums for a bit...

    I've been hunting around the forums for a bit now, but couldn't find an answer to this question, so I figured I'd post. Any advice would be much appreciated...

    I have a 20+ year old Trane...
Results 1 to 8 of 8