    Thanks glennac, When you say round duct, do you...

    Thanks glennac,
    When you say round duct, do you mean rigid or alumaflex ?
  2. Replies
    4
    Views
    414

    Air flow question

    Checking out a American Standard unit 2YCX3060 for poor performance. Found some air flow problems. The unit has 2 floor return grills that have 10" duct pipe. The filters are laying right over the...
  3. Filter shell has small weld leak / repair ideas requested

    Hi everyone,
    I found a small leak in a suction filer shell and am wondering what might be the best way to repair it. It's a BTAS-313-V brass suction filter shell. The leak is at the bottom of the...
  4. Replies
    13
    Views
    488

    I can borrow a flow hood from PG&E training...

    I can borrow a flow hood from PG&E training center to read cfm. A static pressure reading could also work provided I can get a chart from the furnace mfg. My airflow check so far has been to make...
  5. Replies
    13
    Views
    488

    The charging chart is gone, rotted out, so is the...

    The charging chart is gone, rotted out, so is the condensing unit identification plate. The condenser is a older unit, the A coil and furnace are new. The compressor is a Copeland ZR36K3 Rated at...
  6. Replies
    13
    Views
    488

    Would larger increase suction?

    Would larger increase suction?
  7. Replies
    13
    Views
    488

    Would a smaller size piston increase suction...

    Would a smaller size piston increase suction pressure? The evaporator TD was 17F. No temp diff across liquid filter, No difference in pressures with air filter out.
  8. Replies
    13
    Views
    488

    Refrigerant metering problem

    A customer has their furnace and A coil replaced this last winter and wanted the air conditioner charge checked for summer operation. Its a R-22 3 ton system. The A coil is a R-22 AllStyle non-TXV...
  9. @Dallas Duster-- this unit has a single internal...

    @Dallas Duster-- this unit has a single internal pump.

    What we have found --- even though the water fill valve was open, it was not filling the system We manually added water by removing one of...
  10. Nuclrchiller, Yes they are about 3 ft. away from...

    Nuclrchiller,
    Yes they are about 3 ft. away from the unit. I reversed the gauges because thought the return gauge was broken but it is not. I cleaned and flushed the taps.
  11. I found the domestic water valves are open to the...

    I found the domestic water valves are open to the system. There is a back flow preventer then a pressure regulator, the valves are all open. I don't know why they are open or if the should be. The...
  12. Carrier 30RA chiller return water pressure

    Hello,
    I have a customer that has a chilled water system for a school building that has a flow error code. The system has a supply water pressure of 35 psi and the return pressure is about 0-5psi....
  13. Replies
    3
    Views
    366

    Just wanted a second opinion. There is no...

    Just wanted a second opinion. There is no readable wiring diagram on the unit. One thing I didn't mention, when I first got there and turned on the unit after it had been off all night, it clicked a...
  14. Replies
    3
    Views
    366

    Rheem RGAA-08EC gas valve issue

    I was on a no heat service call this morning (Sat)on this Rheem unit. I was finding that the pilot would light and stand for 20 sec. or so and then I would hear solenoid clicking, the pilot would...
  15. Girgling noise at unit start-up and shut down

    Customer has 2 story house, furnace and A coil in attic horizontal. Customer hears girgling when it starts and shuts off. Lennox with TXV. Is this normal ? If not what can be done to keep it quiet?...
  16. Would a evaporative cooler still be the best MUA?...

    Would a evaporative cooler still be the best MUA? I don't know if they make them that small 1200 cfm? The area where the restaurant is located is on a river edge and the humidity ranges from 26% on...
  17. Restaurant kitchen exhaust hood / make up air problem

    I have a customer that has a kitchen that is open to the dining area and the stove area has a 1500 cfm exhaust blower. Next to the hood they have a 5000 cfm evaporative cooler running at full speed...
  18. I've installed 5 Fugitsu systems and they all...

    I've installed 5 Fugitsu systems and they all work great. Customer support is also excellent.
  19. Replies
    20
    Views
    1,497

    Are you checking/replacing the start contactor?...

    Are you checking/replacing the start contactor? /// What barbar said?
  20. Replies
    24
    Views
    3,760

    I just installed 2 Fugitsu units. They are...

    I just installed 2 Fugitsu units. They are awesome! The bigger unit is a ASU15RSL2 and is 21 SEER the smaller was 25. All the Fugitsu units I have installed work great and they are a little less...
  21. Replies
    6
    Views
    777

    410A evaporator coil conversion to R-22

    Has anyone had any experience with a 410A coil TXV conversion to R-22? I have been told that a 036 coil is to small for a R-22 036 condenser. If that is true would you use a bigger coil like a 048...
  22. Replies
    1
    Views
    322

    Found it .... Southwire EZ-IN Mini Split Cable

    Found it .... Southwire EZ-IN Mini Split Cable
  23. Replies
    1
    Views
    322

    Mini Split communication cable

    Hello, I was trying to find the cable mfg that I saw advertising on this site. The electrical cable was for mini-split unit communication. Did anybody happen to write it down? Thanks for any help.
  24. Replies
    21
    Views
    2,351

    This is the Ask Our Pro's forum. In order to post...

    This is the Ask Our Pro's forum. In order to post a response here, you must have verified qualifications and have been approved by the AOP Committee. You may ask a question by starting a new thread....
  25. Siemans 24v contactor coil keeps failing

    Hi, I have a problem with these 75 amp contactors. Last week I found both compressor contactor coils shorted. ( 2 compressor unit) I find it odd that they would both go exactly at the same time. The...