  1. Replies
    8
    Views
    250

    In the NAE under the focus tab, you will have the...

    In the NAE under the focus tab, you will have the object ifentifiter which is 500 in your case. Also you have the 1001 network address.
    If you open the tree, do you see a BACnet object? should will...
  2. Replies
    8
    Views
    250

    NAE55

    Most likely all the NAE's have the device ID as 500. This is the default and 99.99 % of the time never gets changed.

    Second you communicate to the NAE not the ADS. Go into a NAE and from the Tree...
  3. Replies
    9
    Views
    295

    Hello, Installed after 2005, not sure on the...

    Hello,
    Installed after 2005, not sure on the extra year. When it's running, I do see some water coming from the evap coil. The furance is rated for 1200 CFM and based on Mr.Bill, 1 ton = 400 CFM I...
  4. Replies
    9
    Views
    295

    Hello, Checked the duct work all seems good. Not...

    Hello,
    Checked the duct work all seems good. Not sure what is manaul J & D are?? You can tell when the furance is on, as it's moving a lot of air though the duct work. I'll have to check on the...
  5. Replies
    9
    Views
    295

    Tempstar Furance and AC question

    Hello,
    We just purchased a home with a 2005 tempstar furance (T9MPV075F12B1) and AC unit (TXA224AKA2). From what I gather, this furance has multiple taps for the motor. The factory setting is high,...
  6. Replies
    1
    Views
    156

    stat or furance control board??

    Hello,

    Figured this would be a good place to start. I have a furance which runs all the time and does not shutdown. In cooling, the fan starts and then the AC. And it doesn't shutdown. Only when I...
  7. Replies
    10
    Views
    410

    N2 Bus

    Under the NAE, open the N2 bus in the main window. Click on the engineering tab. It might come up with a auto-discovery window say Yes. If it doesn't click on the Relean button. This will scan your...
  8. Paladin

    I guest it's as easy as pie!! Our electrians give us a Paladin tool which worked? And go figure it's a Time Design Reflectometer.
  9. Diasychain

    Good day to all.

    Thanks for the insight. To add onto this, we would disconnect every daisychain connections to the controllers. Then we need to get the distance between each controller and then...
  10. Tool to read the distance of a 2,3 or 4 wire cable.

    Hello,

    I'm looking for a device which willl allow us to read a 2, 3 or 4 wire daisychain communication run.

    We tried a $18K Fluke network tool and didn't like the daisychain. What would be...
  11. Are you using the fieldserver tools on your PC??...

    Are you using the fieldserver tools on your PC?? if not get these from the web and run the Remote User Interface program.

    Are you sure the IP in the fieldserver is correct? what is the sub and...
  12. N2

    Power cycle the working DX9100 and see what version it is. Then power cycle the effected one and check this version.

    Do you have any other TC9102 that are on the network that is not causing this...
  13. Replies
    0
    Views
    135

    JCI LCT Logic - how to create a COS

    Hello,

    In the NAE LCT logic program, I need to active a horn from an input to output. Pretty simple, but I would like to use a COS, so once the latch is reset it won't be triggered again - unless...
  14. Replies
    3
    Views
    191

    Hello, The hotdog looking object has nothing...

    Hello,

    The hotdog looking object has nothing in it for the on/off times. I'm not at the site, but remember that beside the BV object for the default it has a statement saying that if BACnet...
  15. Replies
    3
    Views
    191

    ALC Priority Array

    Hello,

    We have logic program which causes a priority level of 6 (min on/off) if we change the default from Off to on. We don't have anything writing to this at that level and figure it's something...
  16. Replies
    6
    Views
    366

    YUP all 8 PLC's are used up - using all the PLC...

    YUP all 8 PLC's are used up - using all the PLC blocks for a operator lite panel and horns.

    The other option I have is to wrtie logic in the NAE to do the latching, and control the outputs...
  17. Replies
    6
    Views
    366

    Is this the part I don't fully understand. In the...

    Is this the part I don't fully understand. In the PLC, I used a SET command. So when the input goes on it latches this on. The only way to reset this is with the RST command. I don't have room in the...
  18. Replies
    6
    Views
    366

    DX9100 PLC Reset - Expert help needed!

    Hello,

    I have a JCI program with PLC logic that is using a SET command to keep on a lite. That's fine, but I need to Reset this from a NAE and not from the RST in the PLC.

    Is their any JCI...
  19. Replies
    17
    Views
    919

    Thanks - didn't know that.

    Thanks - didn't know that.
  20. Replies
    17
    Views
    919

    Touch Screen

    Hello,

    So time ago, someone had put on this forum a spead sheet on testing several different touch screen panels. I search but couldn't located it.

    Does anyone know were this baby is.

    Thanks
  21. Replies
    4
    Views
    305

    We didn't send any reload command. Once we put a...

    We didn't send any reload command. Once we put a new field controller on the Acrnet, it wants to download all the field controllers for ALL branches (routers).

    We checked teh BBMD and they are...
  22. Replies
    4
    Views
    305

    ALC WebCrtl V6.0 download Question

    Hello,

    We have several routers with around 30 field controllers connected. When we add in another field controller to one router, it tells us to download all the controllers? What I find odd, why...
  23. Replies
    2
    Views
    344

    Hello, The problem turned out to be with IT...

    Hello,

    The problem turned out to be with IT security. Once they opened the ports, everthing is fine.
  24. Hello, We are changing our BMS from Honeywell...

    Hello,

    We are changing our BMS from Honeywell to ABB. The output module that we use from the ABB is only 24VDC. Since most items are 3 wire (share common) we would create a problem with using...
  25. BAPI

    Hello,
    In our OR this is what we did - replaced the JCI stat with a BAPI that output 0-10 for the temperature range and 0-10 for the adjust.
    Then reprogram the controller to accept the 0-10, and...