    You said "Don't have the schematic with me. " If...

    You said "Don't have the schematic with me. " If I can copy and paste the model and Google has it in front of me in 10 seconds, it's a fair assumption you didn't bother looking and spent about as...
  2. Replies
    120
    Views
    4,053

    And there is other items fried in the house...

    And there is other items fried in the house because comcast was there replacing their stuff.
    In the 150 degree attic, I quickly checked as many items as fast I could. I didn't say I was going to...
  3. Replies
    120
    Views
    4,053

    Did I say the transformer was bad? What are...

    Did I say the transformer was bad?
    What are trying to say?
  4. Replies
    120
    Views
    4,053

    GE ECM Model# HD42AE232 Graindaire-WAHM304A...

    GE ECM Model# HD42AE232
    Graindaire-WAHM304A
    Don't have the schematic with me. Board might be still good. I know that the battery powered thermostat is definitely not working because I
    got 27...
  5. Replies
    120
    Views
    4,053

    I have a customer with a bad x13 motor and I'm on...

    I have a customer with a bad x13 motor and I'm on the fence about just replacing it or installing a PSC motor. There is a chance that the control board is gone too so that's why I thought a 24 volt...
  6. Replies
    120
    Views
    4,053

    How easy is it to convert from X13 to PSC? I am...

    How easy is it to convert from X13 to PSC? I am thinking get the same size H.P., rpm, voltage, and a 24 volt contactor instead of using the control board on the fan coil?
    Especially for AC only...
  7. Is it possible? 10 ton condenser connected to two-5 ton air handlers

    I have a restaurant where they have a newer 10 ton condenser.
    The 10 ton fan coil is falling apart. I can get them two new 5 ton fan coils for a great price.
    This might be a dumb question, but is...
  8. Replies
    0
    Views
    83

    venstar T2900 indoor remote sensor

    Hello All
    I have 4- T2900 thermostats. All with the same problem, I cant get the indoor remote sensor to work with the thermostat. I wired a remote sensor to terminal R1 and R ground. I haven't...
  9. Replies
    1
    Views
    242

    Wanted: EWC boards

    Let me know if anyone has an extra or extra's they want to sell. Thanks Joe
  10. Replies
    1
    Views
    389

    Here is the newest link....

    Here is the newest link.
    http://www.ebay.com/itm/231226642894

    Doesn't anyone have a restaurant project? I have installed in Tex-Mex type restaurant. Owners painted them same color as ceiling and...
  11. Replies
    3
    Views
    374

    Thanks Gentlemen, I found the brass fitting in...

    Thanks Gentlemen,
    I found the brass fitting in another box.
    Thank you!
  12. Replies
    3
    Views
    374

    TXV valve fitting

    Hi Guys,
    I bought a new uncased 3 ton coil. I have on my shelf a new 3 ton TXV valve that fits on the coil end, no problem.
    I don't install many TXV valve's so I am having a problem trying to...
  13. Replies
    34
    Views
    1,422

    Ok very true. Thanks jtrammel.

    Ok very true. Thanks jtrammel.
  14. Replies
    34
    Views
    1,422

    Yes. still there and working.

    Yes. still there and working.
  15. Replies
    34
    Views
    1,422

    Icanhas, I appreciate your input on this. Well...

    Icanhas, I appreciate your input on this. Well done!
  16. Replies
    34
    Views
    1,422

    FYI: The FV4 fan coil has the ECM motor so it is...

    FYI:
    The FV4 fan coil has the ECM motor so it is able to slow down the fan to 80% of it's normal speed setting for dehumidification. This is accomplished with wiring in the DH and R circuit to a...
  17. Replies
    34
    Views
    1,422

    Thanks for all replies! I understand the...

    Thanks for all replies!
    I understand the comments regarding that heat mode and humidity control (with outside condenser) is an energy hog.
    Customer does understand the energy use involved. They are...
  18. Replies
    34
    Views
    1,422

    Teddy Bear, I currently have a regular...

    Teddy Bear,
    I currently have a regular heat/cool thermostat for the space. I installed a separate Johnson Control humidistat (common, NO and NC terminals) and connected to Dh end R terminal ...
  19. Replies
    34
    Views
    1,422

    I am not looking into adding any new equipment,...

    I am not looking into adding any new equipment, except for some type of control for heat mode.
    It's a long story
    This house is only 2 years old. Had a huge mold problem in the basement.
    There was...
  20. Replies
    2
    Views
    342

    I am just thinking out loud. Some guys might not...

    I am just thinking out loud. Some guys might not like my idea.
    If you think about it, you really want to have the heat coming out of the floor with the radiant
    and the hot air as the back up source...
  21. Replies
    34
    Views
    1,422

    Dehumidify in heat mode

    Hi to all,
    I installed a Carrier system with condenser and FV4 air handler with a hot water coil on top (hydro air set up)
    The air handler has a Dh and R circuit for dehumidification, but only...
  22. Replies
    11
    Views
    560

    Okay Thanks hearthman, 54regcab, and second...

    Okay Thanks hearthman, 54regcab, and second opinion.
  23. Replies
    11
    Views
    560

    martyinlincoln, I brought some 6" pipe and...

    martyinlincoln,
    I brought some 6" pipe and three-6" elbows because electrician thought it might be the length of the 4" pipe was the problem.
    Obviuosly,I didn't have enough material. I am going...
  24. Replies
    11
    Views
    560

    My dilemma is: An electrician that I work...

    My dilemma is: An electrician that I work together with is selling his house. The buyer's home inspector mentioned in his report that the dry vent circuit needed "attention".
    Didn't say what he...
  25. Replies
    11
    Views
    560

    Second opinion, I have worked on projects where...

    Second opinion, I have worked on projects where we needed to install a booster fan towards the end of the dryer vent circuit.
    Actually the whole circuit was designed by a mechanical engineer (that...