    I would start with making sure you have the right...

    I would start with making sure you have the right size valve before you do anything else.
  2. Replies
    29
    Views
    1,603

    May have been damaged during install or...

    May have been damaged during install or oversized. Also MKC-2 valves have had a problem not closing and require the brass washer repair.
  3. Replies
    4
    Views
    359

    We have some customers using Hoshi heads and...

    We have some customers using Hoshi heads and Follett baggers. Nice setup and easy to use.
  4. Replies
    22
    Views
    1,783

    Check pricing from Rhs or Case you will probably...

    Check pricing from Rhs or Case you will probably get a better deal.
  5. Replies
    27
    Views
    1,768

    Since you didnt actually fix anything I would...

    Since you didnt actually fix anything I would have a very hard time charging the customer for a bunch of parts that didnt need to be installed. Might be an expensive learning experience. If you are ...
  6. Replies
    7
    Views
    641

    What was your voltage at the compressor?

    What was your voltage at the compressor?
  7. Replies
    12
    Views
    993

    Replace the headmaster.

    Replace the headmaster.
  8. Replies
    20
    Views
    1,081

    What is your sh and sc?

    What is your sh and sc?
  9. Replies
    19
    Views
    1,243

    15 percent

    15 percent
  10. Replies
    2
    Views
    315

    If it has an arrow I would position correctly. ...

    If it has an arrow I would position correctly.
    There are some that are not position sensitive.
  11. Replies
    10
    Views
    1,102

    I would use the smallest diameter pipe and create...

    I would use the smallest diameter pipe and create a long coupling and weld up
    Nitrogen purge as welding would be advisable
  12. Replies
    6
    Views
    468

    Its business and everyone has bills to pay. They...

    Its business and everyone has bills to pay. They are paying for your services as well as the machine.
  13. You need to fully diagnose before determining...

    You need to fully diagnose before determining value. Like VTP99 said pierce the system and see whats up.
  14. Have you called tech support? They were very...

    Have you called tech support? They were very helpful with last issue I had.
  15. Replies
    14
    Views
    734

    Last one I worked on was leaking from terminals...

    Last one I worked on was leaking from terminals on compressor.
  16. Replies
    41
    Views
    1,439

    The best way imo would be to make it a pumpdown...

    The best way imo would be to make it a pumpdown system. If you just changed out the lpc for tstat you would have better control but still have migration issue
  17. Maybe not 30 in the real world but bearing change...

    Maybe not 30 in the real world but bearing change is very straightforward. Another reason why I like Follett.
  18. Replies
    20
    Views
    1,359

    Have you checkef to see if you have restriction...

    Have you checkef to see if you have restriction at the strainer for the right hot gas circuit
  19. Replies
    16
    Views
    1,264

    Some service seminars csn be helpful but having...

    Some service seminars csn be helpful but having someone available that is experienced is probably best tech support is good too I believe learning the sequence of operation is the most important...
  20. Replies
    25
    Views
    1,791

    If your super heat is high why would you try to...

    If your super heat is high why would you try to close the txv?
  21. Replies
    5
    Views
    772

    Sounds like that machine is making good ice What...

    Sounds like that machine is making good ice
    What was the original complaint?
  22. Replies
    28
    Views
    1,915

    Check receiver level make sure youre not low on...

    Check receiver level make sure youre not low on gas
  23. Are you checking voltage at compressor?

    Are you checking voltage at compressor?
  24. Replies
    56
    Views
    4,722

    If you charge to clear glass with a 65 degree box...

    If you charge to clear glass with a 65 degree box and then valves throttle down as box reaches temp you're going to stack.liquid and.end.up with high receiver level. My experience may come from...
  25. Replies
    56
    Views
    4,722

    Agreed. I never rely on sight glass to set charge...

    Agreed. I never rely on sight glass to set charge only finish off once proper receiver level set. Very easy to overcharge system using sight glass only especially when dealing with high ambient temps.