    The circuit does turn on and off with the...

    The circuit does turn on and off with the thermostat. If I increase temp, I will see a red light on the zone indicating a call for heat. I think the check flow was tested for another problem and...
  2. Replies
    13
    Views
    1,446

    I appreciate the comments, the only thing I can...

    I appreciate the comments, the only thing I can conclude is that the thermostats are not wired correctly. The basement thermostat was always set to the lowest possible temperature.

    The main...
  3. Replies
    13
    Views
    1,446

    Two thermostats ... There is a switching relay. ...

    Two thermostats ... There is a switching relay. Here are some of the specs and think I attached a picture too.

    • Boiler: Buderus G215/4
    • Burner: Riello 40 F5 262T C8512120 Buderus G215/4...
  4. Replies
    13
    Views
    1,446

    The logimatic controls the temperature based upon...

    The logimatic controls the temperature based upon a program (these can be modified), there is also an outside temperature sensor that regulates the boiler temperature based upon the outside air temp....
  5. Replies
    13
    Views
    1,446

    Buderus Logimatic R2107 Assistnace

    Hello Everyone,

    I need some help with my Buderus Logimatic R2107 configuration. I’m running a Burderus G215-4 boiler (OIL) and have 3 zones in the house. Zone 1 is the main living area (upstairs...
  6. Replies
    11
    Views
    1,789

    Thanks for the advice. One final question...

    Thanks for the advice. One final question regarding the expansion tank. The specs on the Watts ETX-60 Gallon: 6.0Gallon / @12PSI Accepted Volume: 3.0 .... Would this make a difference during a...
  7. Replies
    11
    Views
    1,789

    Yes the entire system is new. This boiler room...

    Yes the entire system is new. This boiler room used to be a wood fired sauna; I removed the sauna stove (which was destroyed) and now use the room to house my boiler. The old boiler was a (1950's)...
  8. Replies
    11
    Views
    1,789

    Thank you. I really appreciate it. This forum...

    Thank you. I really appreciate it. This forum has taught me a lot so anything you can share is definitely helpful. I'm located in NY. The system was installed about 6 months ago.

    I guess my...
  9. Replies
    11
    Views
    1,789

    Thank you for the reply. I think "b" is a...

    Thank you for the reply. I think "b" is a definite, not sure about the others.
    Since I last posted I observed a slight drip coming from the monoflow pipe where it enters the boiler room. I...
  10. Replies
    11
    Views
    1,789

    Thanks for the responses and suggestions. I...

    Thanks for the responses and suggestions. I wrote a response to this thread but for some reason it's being rejected for forbidden words and/or links. The post contains neither, so I'm not sure why...
  11. Replies
    11
    Views
    1,789

    Buderus G215 - Pressure Too High

    Hi Everyone,

    I have a Buderus G215/Riello 40 F5 with a Logimatic 2107 control. Sometime during the night my heating system shutdown. This morning when I looked at the Logimatic display, it...
  12. Replies
    1
    Views
    363

    Heating & Venting Question?

    Hi Everyone,

    I'm hoping someone can provide some advice and/or suggestions. I just purchased a home that has three stacks (1=Oil Burner 2=Fireplace 3=Sauna). I need to replace the oil burner as...