Search:

Type: Posts; User: stat

Page 1 of 3 1 2 3

Search: Search took 0.00 seconds.

  1. Replies
    21
    Views
    3,924

    To the op, Did you get the hot side going?

    To the op,

    Did you get the hot side going?
  2. Replies
    37
    Views
    2,820

    +1

    +1
  3. Replies
    7
    Views
    399

    Trip charge. We are T&M. For flat rate I see...

    Trip charge. We are T&M. For flat rate I see how it could already be figured in and not listed separately.
  4. Replies
    7
    Views
    1,247

    To many times to remember...

    To many times to remember...
  5. Thread: Evap. goes where?

    by stat
    Replies
    16
    Views
    4,046

    Good dehumidification/reheat set up!

    Good dehumidification/reheat set up!
  6. Replies
    20
    Views
    2,031

    They may be running the condenser fan to cool...

    They may be running the condenser fan to cool things down even if the HP switch kills the contactor.
  7. Replies
    33
    Views
    3,251

    I set all me outdoor R22 units CI 10lbs and CO...

    I set all me outdoor R22 units CI 10lbs and CO 2lbs.
  8. SOG in my front pocket

    SOG in my front pocket
  9. Replies
    35
    Views
    1,790

    Fixed many condensers. Like others have said...

    Fixed many condensers. Like others have said Silphosing over the leak is first choice. I have spliced in a piece by sliding a piece of 1/2" over the tube sliding it back and pinching the ends down....
  10. Replies
    28
    Views
    2,711

    Nine years? Really? May be better to start a new...

    Nine years? Really? May be better to start a new thread...
  11. Replies
    29
    Views
    5,419

    I changed one similar to that a while back. The...

    I changed one similar to that a while back. The tenant says you just changed that two years ago, you should have done a better job. I say this what happens if you don't replace the filter. Tenant...
  12. Replies
    26
    Views
    1,921

    +1 on the Windows app.

    +1 on the Windows app.
  13. Replies
    18
    Views
    1,533

    Plenty of small stores and restaurants out there...

    Plenty of small stores and restaurants out there with refrigeration condensing units in the basement.
  14. Replies
    53
    Views
    3,351

    Is the condensing unit indoors or outdoors? If...

    Is the condensing unit indoors or outdoors? If indoors, follow icemeister's advice.
  15. Replies
    18
    Views
    1,533

    Are the evap and condenser in the same space? If...

    Are the evap and condenser in the same space? If not, and the bedroom is 3000sq ft it should work just fine.
  16. Thread: subcooling

    by stat
    Replies
    74
    Views
    4,653

    In other words, excessive subcooling makes the...

    In other words, excessive subcooling makes the TXV oversized.
  17. Replies
    53
    Views
    3,351

    Add a second receiver in series with the first. ...

    Add a second receiver in series with the first. Receivers are cheap. Cost about the same as the suction stop and you don't have to change how the system operates.
  18. Replies
    7
    Views
    813

    My reply to a similar query "The day I can...

    My reply to a similar query

    "The day I can see the future is the day I stop carrying tools for a living."
  19. Replies
    25
    Views
    1,577

    x2 The AC compressor in the store I service has...

    x2
    The AC compressor in the store I service has been out for two years..
  20. Kwik Trip?

    Kwik Trip?
  21. Replies
    41
    Views
    3,654

    There are three roof heights and two wheel bases....

    There are three roof heights and two wheel bases. The picture is of the standard height. I am interested in the medium height long wheel base which I believe is approximately 5'10" inside. Three...
  22. Replies
    41
    Views
    3,654

    Yes. I think it is what I want next. I want to...

    Yes. I think it is what I want next. I want to see one in person.
  23. Replies
    6
    Views
    518

    5%, 45% and staybrite

    5%, 45% and staybrite
  24. Replies
    71
    Views
    3,034

    So now you have a cap tube system with a receiver...

    So now you have a cap tube system with a receiver ?
  25. Replies
    71
    Views
    3,034

    Isn't that second condenser completely full of...

    Isn't that second condenser completely full of liquid?
  26. I just bought MB2 bag to use for trouble...

    I just bought MB2 bag to use for trouble shooting. I was wishing it was a little bigger.
  27. Replies
    29
    Views
    2,470

    In my jurisdiction the fire inspector will shut...

    In my jurisdiction the fire inspector will shut down a kitchen if the exhaust fans are found not to be working. The exhaust fans need to be running in case of fire. He will also require any cooking...
  28. Replies
    71
    Views
    3,034

    Condensing unit R404 TXV/receiver ETC ...

    Condensing unit
    R404
    TXV/receiver
    ETC

    Everybody wins
  29. Replies
    11
    Views
    1,395

    Suction line icing back on a freezer means...

    Suction line icing back on a freezer means nothing. On most of my systems ice on the suction line means everything is working properly. Make sure the evap is ice free, the box is close to temp and...
  30. Thread: Age old debate

    by stat
    Replies
    22
    Views
    1,639

    Been using Stay Brite for 25 years, including R22...

    Been using Stay Brite for 25 years, including R22 medium temp discharge lines. Never had an issue.
  31. Replies
    77
    Views
    7,067

    Around here the service dept of the restaurant...

    Around here the service dept of the restaurant supply company tells the customer it can't be fixed and the unit needs to be replaced.

    Actually, they do that to all equipment they look at. Keeps...
  32. Replies
    32
    Views
    2,673

    Just like the CPR, the pressure limiting TXV...

    Just like the CPR, the pressure limiting TXV prevents the compressor from excessive suction pressure, not flooding. Using the pressure limiting TXV saves you the cost of buying a CPR valve. This...
  33. Replies
    32
    Views
    2,673

    Never installed a condensing unit with an...

    Never installed a condensing unit with an accumulator in 25yrs, including the two low temps I put in last week. I have however seen systems with accumulators still flood compressors.

    Use a...
  34. Replies
    77
    Views
    7,067

    Anything made by Cold-Tech

    Anything made by Cold-Tech
  35. I trap the cooler at the coil, trap the freezer...

    I trap the cooler at the coil, trap the freezer line inside the cooler then tee into the common line
  36. Replies
    8
    Views
    20,385

    Make sure the cut in pressure saturated suction...

    Make sure the cut in pressure saturated suction temperature is below the coldest ambient temperature. Around here on R22 I use 8lbs CI and 2lbs CO. This will keep it running when it is -20F.
  37. Replies
    22
    Views
    2,401

    Screen roller tool

    Screen roller tool
  38. Replies
    23
    Views
    2,417

    I have worked out of a pick up for nearly 25...

    I have worked out of a pick up for nearly 25 years. Most of my trucks have had high side boxes and a gang box behind the cab. I did have a Reading cap once similar to the A.R.E and I liked that...
  39. Thread: Veto tool bags

    by stat
    Replies
    75
    Views
    11,522

    I Have been using a Tech LC for about a year and...

    I Have been using a Tech LC for about a year and it is hands down the best bag I have used. I now also have a Pro Pac. It is a lot easier to haul up a ladder than a shoulder bag, but I don't like...
  40. Replies
    17
    Views
    1,684

    I use 409

    I use 409
  41. Replies
    10
    Views
    915

    I have one account with the furnace next to the...

    I have one account with the furnace next to the dryer and no outdoor CA. Flame sensor needs to be cleaned at least once a year, sometimes twice. I have suggested a second pipe as a solution but...
  42. Replies
    7
    Views
    620

    Refrigerant will migrate to the coldest part of...

    Refrigerant will migrate to the coldest part of the system. If it is colder out side than inside, that's where the refrigerant will be. Makes no difference if the furnace is running. On a -10F day...
  43. Sometimes I put a sight glass there to. Can save...

    Sometimes I put a sight glass there to. Can save having to drag a jug up to the roof.
  44. Thread: Cooler Problems

    by stat
    Replies
    7
    Views
    1,040

    >>>I never could understand why restaurants do...

    >>>I never could understand why restaurants do not adopt the rack system concept. It would be such a better system for them. Plus easier for techs, cheaper on energy. <<<

    Because most only all...
  45. Replies
    25
    Views
    2,232

    And if you want to get the oil out really really...

    And if you want to get the oil out really really fast, don't pump down the crankcase. Don't ask me how I know this....
  46. I have seen many units wired the way you...

    I have seen many units wired the way you describe. They came from the factory that way. I always wire them as the others have described.
  47. Replies
    3
    Views
    937

    Read the links posted on how it works. Be sure...

    Read the links posted on how it works. Be sure to read the section on checking the thermistors. I have found a lot of bad thermistors on these things.
  48. Thread: frosty freezer

    by stat
    Replies
    11
    Views
    1,121

    Is the coil getting completely defrosted during...

    Is the coil getting completely defrosted during defrost? Is the fan side of the coil clear of ice? Are all the heaters working?
  49. Replies
    16
    Views
    2,991

    The p trap is probably filled with muck, stopping...

    The p trap is probably filled with muck, stopping up the drain. Make sure you flush out the drain good once it is thawed.

    I have split armaflex and duck taped it on drain lines successfully many...
  50. Replies
    11
    Views
    5,017

    What type of timer do you have? With a Paragon...

    What type of timer do you have? With a Paragon 8000 series I typically use the 4x30 program. With a Paragon 4000 I use the one long one at night. If you build a frost load during the day affecting...
Results 1 to 50 of 118
Page 1 of 3 1 2 3

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Quality Home Comfort Awards