Search:

Type: Posts; User: richvacr

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    262
    Views
    16,966

    Really A wise man's heart is at his right...

    Really

    A wise man's heart is at his right hand; but a fool's heart at his left. Ecc. 10:2 KJV
  2. Replies
    28
    Views
    1,715

    Good point I asked a few weeks ago and problem...

    Good point
    I asked a few weeks ago and problem has not recurred
  3. Replies
    2
    Views
    324

    Last thing a few days ago is that they are...

    Last thing a few days ago is that they are getting financing to pay bills - so we were told
  4. Replies
    2
    Views
    324

    MTL Cool / Petfresh @ Petco

    Does anyone have experience dealing with MTL Cool out of Quebec Canada?

    Been trying to collect on 3 jobs performed in the states but nothing

    Accounts payable is out of the office and non...
  5. Replies
    28
    Views
    1,715

    Funky looking but t off the same source As for...

    Funky looking but t off the same source
    As for where inside the wall i do not know not in ceiling so either from 3 compartment sink or hand sink
  6. Replies
    28
    Views
    1,715

    If HGV is sticking it is not when I am watching...

    If HGV is sticking it is not when I am watching it
    Dip switches were set to factory default
  7. Replies
    28
    Views
    1,715

    Machine resets - thermistor if it is the problem...

    Machine resets - thermistor if it is the problem is intermittently bad
  8. Replies
    28
    Views
    1,715

    could be but why only the top not the bottom

    could be but why only the top not the bottom
  9. Replies
    28
    Views
    1,715

    I would think faulty thermistor would be more...

    I would think faulty thermistor would be more consistent - at least one out of three cycles

    but i told them i will price a thermistor since it is the cheapest fix
  10. Replies
    28
    Views
    1,715

    Hoshizaki One Beep

    I have a KM1300 SRH stacked units with the top unit every couple days going off on high temperature safety (one beep)

    When I reset and run it everything is close to normal (freeze time is a bit...
  11. Replies
    21
    Views
    1,778

    What is needed is a either a push rod or if the...

    What is needed is a either a push rod or if the door is locked an internal way of forcing it open

    I know when i go into a beer cooler especially that has a padlock I take the padlock with me...
  12. Replies
    11
    Views
    861

    Digital or Manual

    I have been tempted to get digital gauges - Testo's I lean towards
    But I wonder how much a difference it could make
    I'd say my sense of touch & hearing play a large roll (well sight to as a giving...
  13. Replies
    9
    Views
    1,122

    Yes I agree but what are people thinking when...

    Yes I agree but what are people thinking when they mount it in the supply
  14. Replies
    9
    Views
    1,122

    Thermostat bulb in supply air

    Thermostat sensor like a A19 mounted so the supply air effects its operation.

    I have come across this a few times and I don't like it. For a while I thought someone did not know the direction of...
  15. Replies
    1
    Views
    650

    Solar powered RTUs

    Does anyone here have info to learn more about solar hvac applications. I looked Lennox thing.

    Is there anything else out there?
  16. Replies
    7
    Views
    1,142

    price of silver: 15% or dynaflow

    I have been using 15% for sometime but the price is getting crazy. Are people switching to cheaper stuff or paying the price.

    Wish I bought a box when it was around $50 then I could sell it on...
  17. Replies
    0
    Views
    316

    Polaris water heat problems

    Having serious problems with a polaris 130 installed since 2003 (w/o problems) at 5000' above sea level.. Polaris when asked said nothing about elevation.

    Not the first on the scene the others...
  18. Replies
    16
    Views
    3,170

    My gripe is the amount of paperwork and their...

    My gripe is the amount of paperwork and their dysfunctional website
    I can not input the proper local tax rate (fm does not have a cert) in the quote but can in the invoice
    Why do I have to re-enter...
  19. Thread: TXV hot swap

    by richvacr
    Replies
    49
    Views
    5,000

    it you have the change the txv because it is...

    it you have the change the txv because it is malfunctioning possibly from debris changing the lld would be a good thing.

    damm i must be slow not sure if it could change it out with presssure...
  20. Replies
    30
    Views
    4,864

    7 rtu in an hour by yourself? it would take me...

    7 rtu in an hour by yourself? it would take me about that long with gear to walk between units

    maybe you use the makita impact not just for screws
  21. Replies
    2
    Views
    1,182

    Thanks that answered a few questions. Now it...

    Thanks that answered a few questions.

    Now it looks like there is a fault with the board's compressor off timer because I had it running for a while before I took the covers off and found it to...
  22. Replies
    2
    Views
    1,182

    Carrier 38tdb Questions

    Today I came upon a Carrier 38tdb060310 with a problem with the condensate pump - replaced that but

    Back up a minute. The unit is running off a single stage tstat (enough wires to convert to 2...
  23. Replies
    12
    Views
    1,898

    As far as i can tell water flow is good the 3/8...

    As far as i can tell water flow is good the 3/8 tubing from the chill pot to the resevoir apears to be at max flow

    Temp controller just a mech tstat remote bulb in resevoir and a freezestat in...
  24. Replies
    12
    Views
    1,898

    filter need to be changed - none on hand but...

    filter need to be changed - none on hand but water flow is good

    to me dirty filters would lead to low suction pressure, chiller cycling on freezestat
  25. Replies
    12
    Views
    1,898

    Forgot another thing did a compressor efficency...

    Forgot another thing did a compressor efficency test packed it and held 10" hg vacuum for 10 mins.
Results 1 to 25 of 93