Search:

Type: Posts; User: push

Page 1 of 14 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    14
    Views
    2,691

    No Explanation Necessary

    Nifty water heater flue one of my guys ran into (& repaired) a few days ago. Homeowner said "It's been that way for years"
  2. Replies
    12
    Views
    2,173

    I took the picture at an apartment complex. I was...

    I took the picture at an apartment complex. I was there for a no heat call and wandered by that atrocity.
  3. Replies
    12
    Views
    2,173

    Modified Condenser

    Maintenance man handy work
  4. Replies
    10
    Views
    1,825

    Poor Cooling on 3rd Floor Apartments

    Original call: AC just can't keep up in the heat of the day. That last pic is where the siding has rotted out and pigeons have taken up residency in the walls. The only thing separating the apartment...
  5. Replies
    40
    Views
    4,139

    That system is less than a year old and it had 0...

    That system is less than a year old and it had 0 refrigerant in it. I gave them there options and all they wanted was for me to add refrigerant, So I charged it. I have no doubt that it will leak out...
  6. Replies
    43
    Views
    6,889

    HAHAHA, I almost made reference about it being...

    HAHAHA, I almost made reference about it being 100% efficient (not about Dice though) But I figured some wise ass would come along and point out that due to the mechanical inefficiencies of burning...
  7. Replies
    43
    Views
    6,889

    No but in my area Tempstar runs a real close 2nd...

    No but in my area Tempstar runs a real close 2nd because both distributors sell to ANYONE!!!!
  8. Replies
    43
    Views
    6,889

    No, it's dedicated to the garage. It's where him...

    No, it's dedicated to the garage. It's where him and his buddies shoot pool and drink beer.
  9. Replies
    43
    Views
    6,889

    Sadly, not.

    Sadly, not.
  10. Replies
    43
    Views
    6,889

    The Opposite of Awesome

    Furnace in a garage, that's the homeowner standing there. original call was for no cool. I said "You're gonna kill yourself with that furnace" he said "is that pipe supposed to go through the roof?"...
  11. Replies
    40
    Views
    4,139

    Lipstick on a PIG!

    This is some high quality installerin'
  12. Replies
    30
    Views
    18,438

    We've sold ~12 of them and had zero problems as...

    We've sold ~12 of them and had zero problems as of yet. Everyone who has purchased one has been pleased. The 900 series thermostat has some features that are not available in the Honeywell IAQ stat.
  13. Replies
    4
    Views
    2,434

    1969-1971, 7.1 SEER, 24,000btu

    1969-1971, 7.1 SEER, 24,000btu
  14. Thread: What Crack?

    by push
    Replies
    5
    Views
    1,365

    heh, that's the rest of the story. It had about a...

    heh, that's the rest of the story. It had about a 6" split in it as well. :rolleyes:
    Couldn't get a picture of it though. :(
  15. Thread: What Crack?

    by push
    Replies
    5
    Views
    1,365

    What Crack?

    Landlord wall furnace repair.
  16. Thread: Trane unit info?

    by push
    Replies
    11
    Views
    2,821

    3 Ton XL20i ARI numbers, 3220685 3220716...

    3 Ton XL20i ARI numbers,
    3220685
    3220716
    3220717
    3220686
    3220677
    3220691
    3220718
    3220699
    3220678
  17. Replies
    9
    Views
    1,471

    The XL15i is aesthetically more pleasing,...

    The XL15i is aesthetically more pleasing, considerably quieter, and will drive the entire system warranty up to 10 year parts. That's in addition to the 2 SEER point increase.
  18. Replies
    47
    Views
    4,267

    Warning Propaganda Ahead

    Linked from another thread on this site and not entirely applicable to your question. But semi-related to some of your questions.
    ...
  19. One more comparison chart

    One more comparison chart
  20. spine fin propaganda

    spine fin propaganda
  21. Spine fin performance study may or may not be...

    Spine fin performance study may or may not be relative to what you're after
  22. I'm not entirely sure I would call that outdated....

    I'm not entirely sure I would call that outdated. I understand the 20i's are slowly becoming available (in our area anyway) but we still sell 19i's as well.
  23. I'm not familiar with the pulse noise you're...

    I'm not familiar with the pulse noise you're talking about, but the reason the coil cabinet is wider than the furnace is because the only rated match with any size XL19i heat pump is a 5 ton indoor...
  24. Replies
    9
    Views
    1,593

    I asked the homeowner that exact question, and he...

    I asked the homeowner that exact question, and he said "No one had touched it". I take that to mean he did it himself, because obviously that furnace has not ran in that condition.
  25. Replies
    9
    Views
    1,593

    It just wont light!!

    Original call was "No Heat".......I get there and find the burner rack had removed and then put back in using the wrong screw holes leaving a good 1 1/2" between the burners and the orifices. They...
Results 1 to 25 of 346
Page 1 of 14 1 2 3 4
Comfortech Show Promo Image