  1. Replies
    10
    Views
    2,182

    In that case replace the line set always. Why do...

    In that case replace the line set always. Why do you want to put a new 410a system on a line set that ran R-22 and mineral oil in it for lord knows how long. You have two things going for you to tell...
  2. Replies
    7
    Views
    803

    I never use flex. Insulated metal is the way to...

    I never use flex. Insulated metal is the way to go. How far is the run?
  3. Replies
    10
    Views
    2,182

    Are you replacing an R-22 unit?

    Are you replacing an R-22 unit?
  4. Replies
    10
    Views
    2,182

    1/2" liquid line won't cause a pressure drop if...

    1/2" liquid line won't cause a pressure drop if it's too big. It will cause a drop in velocity which in turn could cause oil problems with 410A. What is the length of the line set? I don't install ...
  5. Replies
    23
    Views
    3,609

    What kind of filter do you have on the system?

    What kind of filter do you have on the system?
  6. First off, did you make sure you don't have any...

    First off, did you make sure you don't have any problem with the drain line or drain pan.
    I couldn't see your pics to understand where the leaks are exactly ,but If your running on low speed most...
  7. Replies
    27
    Views
    2,090

    What it did for me was to never trust anyone...

    What it did for me was to never trust anyone again. Which is sad because my business is in a small town where you used to not have worry about things like this so much.
  8. Replies
    11
    Views
    2,534

    Wow! That looks really sad. Like said above , you...

    Wow! That looks really sad. Like said above , you need a complete redue. Don't get the same guy that put it in the first time back. It really upsets me to see work like that. I hope you find someone...
  9. Are you really a tech? Put an ambient thermostat...

    Are you really a tech? Put an ambient thermostat on the fan that shuts it off at 70deg air temp. HUMM , you might as well go buy a new compressor while your at it.
  10. Replies
    4
    Views
    717

    WORD! The green gas valve is the modulating one.

    WORD! The green gas valve is the modulating one.
  11. Thread: superheat

    by suksinline
    Replies
    19
    Views
    1,379

    Superheat and subcooling are always important...

    Superheat and subcooling are always important ,but in your case it will be used more for protecting the compressor and making sure the system charge isn't to far out of wack.

    There will be no one...
  12. Replies
    27
    Views
    2,090

    I feel for you as I had the same thing happen to...

    I feel for you as I had the same thing happen to me. About 15 years ago I was working on starting up some Fryers at a fairground and needed a part. I left me tools in the main building and was gone...
  13. Replies
    11
    Views
    925

    I have two problems with this whole thing. First...

    I have two problems with this whole thing. First you say your company has been adding freon to the system every year. Also What made you think the system was low on freon when you found the problem...
  14. I'm new to this site but not to the field. I'm a...

    I'm new to this site but not to the field. I'm a carrier dealer and I've read most of this thread. There are many questions that need to be answered before a size can be given. To the Op, you said...