  1. Thread: Brixing

    by joegrind
    Replies
    15
    Views
    998

    It's important to have the refrigeration system...

    It's important to have the refrigeration system working properly as the syrup will run slower The colder it gets
  2. Replies
    51
    Views
    3,146

    The older Alco two-piece TXVs had a superheat to...

    The older Alco two-piece TXVs had a superheat to turn adjustment ratio! I forget the Ratio but it was something like a turn =.5 deg sh. If you were 2 deg low you would simply turn it in 4 turns and...
  3. Replies
    9
    Views
    1,345

    Don't want to sound like a parts changer...

    Don't want to sound like a parts changer but....... Ignition modules are just not a lot of money! If all of the usual checks come up with nothing, I go for the module and ignition assembly in one...
  4. Replies
    6
    Views
    446

    1500 4x4 Locking differential and Z 71 package,

    1500 4x4 Locking differential and Z 71 package,
  5. Replies
    6
    Views
    446

    Obviously I posted in the wrong forum.... It does...

    Obviously I posted in the wrong forum.... It does have a gun rack!!!!!!!!
  6. Replies
    6
    Views
    446

    2011 Sierra 5.3 w/ 6 speed!

    Had the truck since new, always found a little clunky in the back end. Had it at the dealer couple of times they said the leaf springs need to be torqued but problem is not solved any of you guys...
  7. Replies
    15
    Views
    1,504

    Sounds like you're working through it, just take...

    Sounds like you're working through it, just take an extra look at that oil pressure control. If memory serves me correct an OEM cuts out at six Pounds. In a pinch some guys will use a Ranco/ Penn,...
  8. Replies
    15
    Views
    1,504

    Carlisle compressors usually run a lower oil...

    Carlisle compressors usually run a lower oil pressure if you reference it to a Copeland, 12 psid isn't out of line, Is it actually cutting out on you?
  9. That's a sweet looking set up!

    That's a sweet looking set up!
  10. It's hard to believe that you would require a...

    It's hard to believe that you would require a "cold trap" for this application, but try searching for some threads, I was involved in one recently. If you have one that's easily accessible it would...
  11. Replies
    619
    Views
    113,374

    No heat in master bedroom was the complaint !...

    No heat in master bedroom was the complaint ! Poor airflow coming from floor diffuser, lift grill and feel for damper and found humongous dildo being hidden in the boot! Husband was looking over my...
  12. Replies
    26
    Views
    2,303

    I mean no offense to my esteemed colleagues with...

    I mean no offense to my esteemed colleagues with my previous post! All of that information does come into play, Sometimes we forget how we need to be flexible in this industry. There is rarely a...
  13. Replies
    26
    Views
    2,303

    That's funny Riderman! About a week ago I tried...

    That's funny Riderman! About a week ago I tried to give a simple answer to a simple question similar to like you're asking and just got railroaded. He asked a simple superheat question that required...
  14. just because we picked this industry doesn't mean...

    just because we picked this industry doesn't mean we forfeit our summer as well! We have to nut up a little bit this time of year but at the end of the day you deserve a good quality of life and...
  15. Replies
    17
    Views
    1,331

    One of the other members recently posted a great...

    One of the other members recently posted a great video from YouTube as to the value of running nitrogen through While brazing! I don't recall which forum it was in, try to search it
  16. Wow, seven calls a day! I can't remember the last...

    Wow, seven calls a day! I can't remember the last time I pulled that off! I think that is an unrealistic expectation and puts a lot of undue stress on the service tech If it is expected daily! That...
  17. Replies
    6
    Views
    1,092

    Sorry boss, I did not realize I was in the AOP

    Sorry boss, I did not realize I was in the AOP
  18. Replies
    6
    Views
    1,092

    Check the manufacturer Of the chillers Integrated...

    Check the manufacturer Of the chillers Integrated Part load values, You may be running a lot more efficient than you think When running both machines
  19. Thread: capacitors?

    by joegrind
    Replies
    22
    Views
    1,870

    Above and beyond the shock value of the capacitor...

    Above and beyond the shock value of the capacitor itself, a lot of injuries Occurr with the reaction of pulling your arm back And cutting it on something or jumping back and tripping and falling....
  20. Thread: psycrometer

    by joegrind
    Replies
    42
    Views
    3,928

    No, in the post you quoted of me I clearly...

    No, in the post you quoted of me I clearly stated that I guess I misunderstood'But for the record in my humble opinion superheat and subcooling to me are just two numbers, what you do with those...
  21. Thread: psycrometer

    by joegrind
    Replies
    42
    Views
    3,928

    the OP Originally asked a very simple question ,...

    the OP Originally asked a very simple question , Everybody is offering up opinions and charging procedures for equipment that he never asked for, All are valid and differ depending on the equipment...
  22. Thread: truck stock?

    by joegrind
    Replies
    15
    Views
    1,492

    I would like to see a couple of hard start...

    I would like to see a couple of hard start kiits,filter/dryers, single and dual capacitors, some contactors and a few transformers, And a couple of the bullet style low and high pressure switches
  23. Thread: psycrometer

    by joegrind
    Replies
    42
    Views
    3,928

    Maybe you got me on a technicality, maybe I've...

    Maybe you got me on a technicality, maybe I've been out of the residential arena for too long! I guess I don't understand how it can be calculated as it is a real-time measurement of the here and now...
  24. Thread: psycrometer

    by joegrind
    Replies
    42
    Views
    3,928

    The original posters question has distorted...

    The original posters question has distorted throughout the thread is a simple yes or no question as superheat is the temperature above the refrigerant saturation and subcooling is a temperature below...
  25. Replies
    3
    Views
    650

    Double check the pneumatic tubing is installed as...

    Double check the pneumatic tubing is installed as per installation instructions, If you're showing a lot of miscellaneous sensor faults, usually it is one bad sensor or transducer Stealing voltage...
  26. I think I read the whole thread, and hope I...

    I think I read the whole thread, and hope I didn't miss anything, If you change the condensing unit and kept the original evaporator with the appropriate TX valve , All things being equal it is the...
  27. Thread: CVHF surging

    by joegrind
    Replies
    39
    Views
    4,732

    Does a CVHF like 65 deg tower water????? Maybe...

    Does a CVHF like 65 deg tower water????? Maybe It's just growling at you a little bit!
  28. Thread: Optispeed!

    by joegrind
    Replies
    0
    Views
    480

    Optispeed!

    Why do I have so much coolant left over???? Been doing alot of "Form 7" Re-assemblys on Yk's of various sizes! After draining, filling, and toping up, I am still left with 2.5 gal of...
  29. Replies
    8
    Views
    1,725

    had this problem once! the bas would shut the...

    had this problem once! the bas would shut the pump down on a sched. therefor opening flow switch and stoping chiller.. BUT>>> the flow switch was stuck closed and it would fault this code
  30. Replies
    18
    Views
    1,515

    I'll through in my 2 bits... All s/h is really...

    I'll through in my 2 bits... All s/h is really doing is insuring no liquid is coming back to the comp! the lower the s/h the better the nre ( in a truly theoretical sense) true efficiency would be @...
  31. Replies
    24
    Views
    3,211

    Just got home from this exact call. spent a while...

    Just got home from this exact call. spent a while troubleshooting the starter before I bumbed my head on the igv arm fully extended out ! ouch that hurt. igv works in manual, will have to...
  32. Replies
    11
    Views
    1,138

    Only problem was throwing belts monthly. threw it...

    Only problem was throwing belts monthly. threw it out there, changed to " standard" B belts vs cogged and belts lasted until next ssv and beyond.???? Cant explain why. Just saving the world one...
  33. Replies
    13
    Views
    1,018

    try the local 787 union hall in brampton. I'm...

    try the local 787 union hall in brampton. I'm fairly new to the union but am in awe with the training and hands on available for apprentices and journeymen alike
  34. Replies
    11
    Views
    1,138

    sorry i was a little getting back on this one.......

    sorry i was a little getting back on this one.... changed from bx to "standard "b" belts and problem solved
  35. Replies
    6
    Views
    1,265

    could only find pics with Buddy and lady...

    could only find pics with Buddy and lady love???Am I on the right site?????
  36. Replies
    9
    Views
    757

    Is a 48HJ cooling only ????? If it has a heating...

    Is a 48HJ cooling only ????? If it has a heating section, could have a bad / shorted ignition module????
  37. Replies
    6
    Views
    1,265

    got pics of my handsome mug sandwiched between...

    got pics of my handsome mug sandwiched between 2000 ton trane cent and two york 1200 ton absorbers up for grabs.. could not find contact info?????
  38. Replies
    16
    Views
    3,144

    will you quit making me drink booze then post!...

    will you quit making me drink booze then post! its not fair to me or the other members
  39. Replies
    16
    Views
    3,144

    should you guys really be talking about...

    should you guys really be talking about this??????? the admin password is privelaged info and you better have a good F#@$ing reason why you want it! Why would anyone want this info????? note .......
  40. I would love to here a rule of thumb here!

    I would love to here a rule of thumb here!
  41. Replies
    17
    Views
    1,830

    the problem in canada being a joegrind is that...

    the problem in canada being a joegrind is that the husbands want you to take their wives with you and the only thing to steal out of the fridge is organic vegetables and soya milk
  42. Replies
    17
    Views
    1,830

    The Hyatt has cooling towers, Check with their...

    The Hyatt has cooling towers, Check with their maint dept. I've seen their chemical feed pumps and chems, Most systems once set up, are automatic as long as you have the chemicals and everything is...
  43. Replies
    8
    Views
    1,236

    What are you reseting??? the control panel or the...

    What are you reseting??? the control panel or the overloads?? if its the latter, Ive installed ICM 450 phase?voltage monitors to shut machines down before a manual reset is required.
  44. Replies
    11
    Views
    1,138

    installation 1.5 years, slide wear,alligned...

    installation 1.5 years, slide wear,alligned properly. belts seem to last about 1 month, drive 6" adj,blower around 9"
  45. Replies
    11
    Views
    1,138

    blowing belts at a rapid pace!! has a 20 hp...

    blowing belts at a rapid pace!! has a 20 hp supply fan,with two bx43 belts.pullys are fine, wondering if drive was undersized??? thinking of changing double pully for a triple. any thoughts...
  46. Replies
    9
    Views
    2,395

    don't forget about the contactor>>>take a voltage...

    don't forget about the contactor>>>take a voltage drop reading across each pole.
  47. Replies
    33
    Views
    3,730

    subcooling has an added bonus, that for every 1...

    subcooling has an added bonus, that for every 1 deg sc = .5% increase in refrigeration effect
  48. Replies
    7
    Views
    1,698

    I have twenty two large ahu's 20-45 tons seems...

    I have twenty two large ahu's 20-45 tons seems like i've tried everything, every 3 months I treat coil with self rinsing cleaner, vacuum drainpan, use bleach nd water to scrub pan then put tabs in...
  49. Replies
    4
    Views
    796

    Sorry for my momentary lapse of reason!!!!!after...

    Sorry for my momentary lapse of reason!!!!!after doing large comm & industrial A/C for so long sometimes you look at small systems and and you feel their not worth your time. I know this is the wrong...
  50. Replies
    4
    Views
    796

    I came accross 2 15 year old 3/4 hp R-12...

    I came accross 2 15 year old 3/4 hp R-12 coolers(never serviced) systems are tight. cleaned evaps and a few bubbles are appearing in the sg now. Time and $ are preventing the cust from auth retro....