Search:

Type: Posts; User: jimmyed

Page 1 of 13 1 2 3 4

Search: Search took 0.02 seconds; generated 33 minute(s) ago.

  1. Replies
    0
    Views
    416

    Mitsubishi Fail...

    Took 3 tries to get me a fan motor.

    First two showed up like this.
    https://farm9.staticflickr.com/8675/16628509962_f6d58feaa8_h.jpg

    So I had the supply house put on the PO to package the...
  2. Replies
    3
    Views
    357

    ADP Coils? With what outdoor? Why not just use...

    ADP Coils? With what outdoor? Why not just use bryant coils?

    Media filters... Not sure why y'all hacked the side of the fan coil open. Put it on a base.
  3. Replies
    17
    Views
    632

    It still lets dust by is the point. We put media...

    It still lets dust by is the point. We put media filters on everything and most get changed once a year. We never have to clean coils, seldom if ever have condensate drains plug, and a clean fan...
  4. Replies
    17
    Views
    632

    All kinds of room, We don't give them the option....

    All kinds of room, We don't give them the option. Just include it in every bid...
  5. Replies
    0
    Views
    158

    Veto LC and MC comparison?

    I bought the MC, impressed with the bag, but could use a bit more room. Does anyone have the LC and the MC and could get a picture of the two side by side? I am not so sure I want to move up to a...
  6. Replies
    17
    Views
    632

    Media filter..... Put one on every furnace!

    Media filter..... Put one on every furnace!
  7. Replies
    30
    Views
    6,001

    Could have made it straight and changed...

    Could have made it straight and changed transition to the coil. I wanted it up close to the wall, there is another wall to the left of the return fairly close, wanted to leave as much room as I...
  8. Replies
    8
    Views
    519

    Those amazon ones look decent if they have big...

    Those amazon ones look decent if they have big enough clips.
  9. Replies
    8
    Views
    519

    Jumper wires, aka limit switches.

    I would give $20 for one that was 12" long, had 2 nice alligator clips on it with soft covers, and really soft wire, like silicone coated fine stranded wire.

    Ones I have now are grossly over...
  10. Replies
    15
    Views
    1,547

    Cool stuff!

    Cool stuff!
  11. Replies
    6
    Views
    973

    More barn madness

    Uhhhhh... We put this modular blower in this pole barn 8 years ago. Worked fine, just had a Y fitting on the supply with 2 registers and heated the barn well. Then she had a loft built. Then she...
  12. Replies
    19
    Views
    1,863

    The only thing that left me wondering, was the...

    The only thing that left me wondering, was the intake right in the way of the coil but I'm sure its removable.

    Straighten up the wires and you good.
  13. Replies
    39
    Views
    3,002

    Doesn't need a trap, drip leg is about useless...

    Doesn't need a trap, drip leg is about useless here but there is one. Oatey clear glue and cleaner.
  14. Replies
    39
    Views
    3,002

    I used Price registers, the louvers are each...

    I used Price registers, the louvers are each individually adjustable, both up and down and left to right. Barn is only 30' wide I think. Easy to throw that much air across it, even with a rather...
  15. Replies
    39
    Views
    3,002

    thanks for the compliments everyone!

    thanks for the compliments everyone!
  16. Replies
    39
    Views
    3,002

    And I do the opposite! Tried leaving the return...

    And I do the opposite! Tried leaving the return up high, but that didn't work. Just warmed up the air up top and never got any of the cold air off the floor. We experimented on the unit in our shop,...
  17. Replies
    39
    Views
    3,002

    You're talking about an ssu.. Those are for old...

    You're talking about an ssu.. Those are for old homes with 30amp circuits. Basically fuse down the appliance. Unit had a 15 amp breaker. No need for a fuse. I'll replace a handful of those...
  18. Replies
    39
    Views
    3,002

    Barn/Shop unit. Heat only.

    https://farm8.staticflickr.com/7544/16131820845_c422330778_h.jpg

    https://farm8.staticflickr.com/7540/15946060157_6b717010b7_h.jpg
    ...
  19. Replies
    14
    Views
    2,286

    https://farm9.staticflickr.com/8600/15944389008_b1...

    https://farm9.staticflickr.com/8600/15944389008_b164e400c2_h.jpg

    Didn't take long. Wouldn't get past 66 degrees in the house. Filter full of drywall dust and paint. Filter stopped most of it...
  20. Replies
    32
    Views
    3,491

    Who doesn't keep pilot orifices on their truck?...

    Who doesn't keep pilot orifices on their truck? Both natural and LP. Their cheap. I would have fixed it and left.
  21. Replies
    39
    Views
    5,861

    Filter is in the box on the right side of the...

    Filter is in the box on the right side of the furnace. 5" media filter. I don't use the slot in the fan coil.
  22. Replies
    14
    Views
    2,286

    Homeowner was in charge, wanted trunk ducts up...

    Homeowner was in charge, wanted trunk ducts up tight with the beam. There again, homeowner in charge that knows absolutely nothing about building a house... It was a frustrating job..

    I put a...
  23. Replies
    14
    Views
    2,286

    Dozer return ducts man!

    Dozer return ducts man!
  24. Replies
    14
    Views
    2,286

    Waterfurnace series 3 geo. New home

    New home, home owner is in charge. Amish are building it. Whole project is a huge cluster ****. That big mess of 2x's next the the furnace is what the beam sits on because it was cut too short. No...
  25. Replies
    35
    Views
    3,816

    heat tape in the crawl? It's not gonna freeze...

    heat tape in the crawl? It's not gonna freeze there. It is gonna freeze in the furnace in the attic!
  26. Replies
    35
    Views
    3,816

    So whats to keep the furnace drain from freezing...

    So whats to keep the furnace drain from freezing up when it gets cold? No way that would fly here.
  27. Replies
    30
    Views
    6,001

    Get to job at 8, finish up around 4-5. All the...

    Get to job at 8, finish up around 4-5. All the sheet metal stuff is made before we start tearing things out.
  28. Replies
    30
    Views
    6,001

    probably rector seal tru blue

    probably rector seal tru blue
  29. Replies
    30
    Views
    6,001

    It does, how would you know it didn't? You can't...

    It does, how would you know it didn't? You can't even see it...
  30. There is, That is a 1/2" cpvc street 90 slipped...

    There is, That is a 1/2" cpvc street 90 slipped inside a 3/4 pvc 90, no glue or anything. Plenty of air gap there.
  31. Replies
    39
    Views
    5,861

    Shop Ticket holders, office supply places have...

    Shop Ticket holders, office supply places have them.

    Not sure on the drywall.
  32. Replies
    39
    Views
    5,861

    There are a lot of pieces to a filter box. Cut...

    There are a lot of pieces to a filter box. Cut out on a plasma table. They are insulated as well. Many different variations of them. Ill snap some pictures next time I have one in my hands.
    Filter...
  33. Honeywell lol Never had a Jackson board go bad....

    Honeywell lol Never had a Jackson board go bad. I am replacing honeywell products on a regular basis. Zone boards, thermostats… Not a fan of their stuff.

    A guy just about has to keep a...
  34. Media filter? O_O

    Media filter? O_O
  35. ahh cool! Wondered if it was staged. Probably...

    ahh cool! Wondered if it was staged. Probably run in low stage most of the time..
  36. Replies
    70
    Views
    7,351

    Only people that make money driving up and down...

    Only people that make money driving up and down the roads are truck drivers….
  37. Is there a big crawl space or? I just don't see 6...

    Is there a big crawl space or? I just don't see 6 tons of house there, unless it is glass maybe? ha
  38. Replies
    70
    Views
    7,351

    Motors on the truck 2- 1860 1861 1862 2- 5460...

    Motors on the truck
    2- 1860
    1861
    1862
    2- 5460
    5461
    5462
    5464
    5471
    5441h
  39. Replies
    70
    Views
    7,351

    We probably go through 15 wheels a year. Keep...

    We probably go through 15 wheels a year. Keep extra's in the shop to restock with.
    There are a slew of rescue motors and some others, Ill get back to you with numbers.





    We keep the 3...
  40. Looks good! Real shame about the Lennox part...

    Looks good! Real shame about the Lennox part though!
  41. Replies
    70
    Views
    7,351

    Where do you keep all the parts? We keep at least...

    Where do you keep all the parts? We keep at least 15 motors and 3 blower wheels on the service truck at all times. Where would those go?
    What about inducers in the winter. Keep half dozen or so...
  42. Replies
    33
    Views
    4,107

    Weird y'all don't see this much. We keep 3 blower...

    Weird y'all don't see this much. We keep 3 blower wheels in stock on the truck and a slew of them at the shop. Changed one yesterday, had it on the truck.

    Probably do 10-15 of them a year.
  43. I am not sure off hand, I know other cartridge...

    I am not sure off hand, I know other cartridge pumps like that draw very little.
  44. Figured out how much return I needed. The area...

    Figured out how much return I needed. The area of a 10" circle is 78sq" roughly. The area of a 18" circle is 254sq", subtract the 10" from that and you get 176sq", which is equivalent to a 15"...
  45. Wandered around the house for an hour trying to...

    Wandered around the house for an hour trying to figure out how to get supply and return upstairs. This was best idea I could come up with
  46. Yes a concentric.. Seemed to be the best option....

    Yes a concentric.. Seemed to be the best option. I threw out the idea then canned it and the more I thought about the more I thought i could make it work.
    ...
  47. Lol foil tape.

    Lol foil tape.
  48. I only insulate them if they are in an attic or a...

    I only insulate them if they are in an attic or a garage.
  49. That's an 18" return... 10" supply runs right...

    That's an 18" return... 10" supply runs right through it.
  50. I think he was referencing it not having ac...

    I think he was referencing it not having ac before I got there.

    Owner build home. Guess they thought they didn't need ac. You should see the ****ting mess of a boiler setup I have to figure out…...
Results 1 to 50 of 626
Page 1 of 13 1 2 3 4