Search:

Type: Posts; User: AllStateTech

Page 1 of 7 1 2 3 4

Search: Search took 0.01 seconds.

  1. It's supposed to cool all the time;)

    It's supposed to cool all the time;)
  2. Replies
    47
    Views
    1,742

    Yeah like many things on cond unit....i mean for...

    Yeah like many things on cond unit....i mean for real cheap ypull get a 3 ton no safeties just barebone but youll end up paying down the road...thats what i hear on recips their good but not...
  3. Replies
    47
    Views
    1,742

    Yeah it makes sense on places that have funny...

    Yeah it makes sense on places that have funny voltage but i too am curious as to why...i know it helps overecome pressure after a system has equallized but do they really help? Is there any data or...
  4. Replies
    14
    Views
    641

    Im installing a tempstar unit and because of...

    Im installing a tempstar unit and because of space issues im mounting the txv outside the cabinet as well as the equalizing line. Im going to insulate it as always. On pipes smaller than 7/8 the bulb...
  5. Replies
    10
    Views
    368

    Use an aed much easier!

    Use an aed much easier!
  6. Replies
    19
    Views
    636

    It could hypothetically cause a large pressure...

    It could hypothetically cause a large pressure drop..i wouldnt just another place a restriction could occur
  7. Replies
    5
    Views
    296

    I guess i didnt mean converting just using a 410...

    I guess i didnt mean converting just using a 410 coil and a 22 txv
    Brcause the custome doesnt want to pay for a 410 system
  8. Replies
    5
    Views
    296

    Txv mounting

    Installing a tempstar a/h and converting it from 410 to 22. The issue is that after removing the piston to install the txv there isnt much room to braze in the txv. What are your guys thoughts on...
  9. Replies
    4
    Views
    249

    Meet me there at beer 30!

    Meet me there at beer 30!
  10. Replies
    11
    Views
    601

    Wow...customers do the darnest things

    Wow...customers do the darnest things
  11. Replies
    11
    Views
    601

    Ive seen this when i was in school...for all the...

    Ive seen this when i was in school...for all the super cheapies out there i guess aka hack jobs. The is a company that manufactures sheet metal that screws to the floor joists and creates a duct...
  12. Replies
    8
    Views
    385

    I doubt it would be that significant

    I doubt it would be that significant
  13. Replies
    8
    Views
    385

    When i see stuff like that or sometimes it...

    When i see stuff like that or sometimes it happens to me (whistle whislte ) i grab my adjustable and round it out best i can...that mighy just be considered a hack job trick!
  14. Replies
    4
    Views
    249

    Dawg you the best! Beers on me

    Dawg you the best! Beers on me
  15. Replies
    15
    Views
    702

    I woukd also sand the line vefore testing, you...

    I woukd also sand the line vefore testing, you would be surprised how much temp difference there is on a clean piece of copper. In ny we used to do and energy efficiency testing on units and we found...
  16. Replies
    4
    Views
    249

    First company a/h

    Have an a/h mn: 30vdxo-hp its a 2.5 ton r-22 coil. Its from a very old quote and i cant find the voltage on it, any help is appreciated. Is there any one site a tech can sign up for to have acess to...
  17. Thread: TXV???

    by AllStateTech
    Replies
    28
    Views
    2,003

    Rundawg can you send me that info as well please...

    Rundawg can you send me that info as well please

    Sent from my SCH-I545 using Tapatalk
  18. Replies
    6
    Views
    247

    I never clicked your profile to check but the...

    I never clicked your profile to check but the proper way would be a one room load calc. Whats the dimensions of the room, how many windows any doors?

    Sent from my SCH-I545 using Tapatalk
  19. Replies
    6
    Views
    247

    Do you know how to do installs? Are you a tech or...

    Do you know how to do installs? Are you a tech or a homeowner? You need to do a load calc

    Sent from my SCH-I545 using Tapatalk
  20. Thread: r22

    by AllStateTech
    Replies
    7
    Views
    507

    Sent from my SCH-I545 using Tapatalk

    Sent from my SCH-I545 using Tapatalk
  21. Replies
    3
    Views
    208

    Agreed nebeast.. cap tube isnt specific to...

    Agreed nebeast.. cap tube isnt specific to refrigerant bwd11 yet just the design temp and compressor....length of cap tube is impprtabt to achieve the design temp but ive also worked on some units...
  22. Thread: r22

    by AllStateTech
    Replies
    7
    Views
    507

    From what someone told me at the supple house...

    From what someone told me at the supple house their was so much excess they lowered the prices to sell it..people were having a lot of luck with mo99 and nu22 that they stopped buying r22 because it...
  23. Replies
    31
    Views
    2,061

    And the answer is...airflow, is it an ecm...

    And the answer is...airflow, is it an ecm motor....is the plastic still on the filter? Ive seen it before

    Sent from my SCH-I545 using Tapatalk
  24. Replies
    24
    Views
    905

    Yeah i assume it woulf be similar to a series a...

    Yeah i assume it woulf be similar to a series a brand sells such as luxaire acclimate etc.... almost anything from home depot is junk st ranger lol

    Sent from my SCH-I545 using Tapatalk
  25. Replies
    24
    Views
    905

    Builders Grade Equipment?

    Just thought id share, I was talking to a supply house for a price for a 3 ton temp star r-22 unit, dry charged obviously. The counter guy asked me if i wanted the builders grade condenser or the...
Results 1 to 25 of 174
Page 1 of 7 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event