Search:
Type: Posts; User: wrecknician
Search: Search took 0.00 seconds.
-
06-26-2009, 07:57 PM
- Replies
- 46
- Views
- 1,287
yep there are other themostats that will do what...
yep there are other themostats that will do what you want, Just didnt want you to buy an iaq and be disappointed. Totaline makes one too, I cant remember the model, and its prbably changed, but it...
-
06-25-2009, 10:13 PM
- Replies
- 46
- Views
- 1,287
last year our salesman sold an iaq with a...
last year our salesman sold an iaq with a truesteam, with the promise of summertime operation. the installers couldnt make it work,
after reading the instructions, I added a duct mounted manual... -
06-25-2009, 06:30 AM
- Replies
- 46
- Views
- 1,287
Stick with the truesteam and a standard...
Stick with the truesteam and a standard humidistat.
If you want a new tstat i like the HW 8000.
You wont get any real humidification from anything but steam in the summer months. Bypass and fan... -
06-24-2009, 09:48 PM
- Replies
- 46
- Views
- 1,287
Dont, Dont, Dont use a HW iaq tstat with true...
Dont, Dont, Dont use a HW iaq tstat with true steam if you need summertime humidity. The Iaq tstat must either be calling for heat or the last call from the thermostat had to be a call for heat. I...
-
04-26-2006, 07:03 AM
Thread: Soleus Air
by wrecknician- Replies
- 6
- Views
- 866
Soleus is cheep to buy, and they work ok, This...
Soleus is cheep to buy, and they work ok, This product used to be Hitachi.
Soleus customer support for homeowners and sevice companies is horrible.
If you buy it, be prepared to throw it away when... -
02-17-2005, 08:00 PM
Thread: comfortmaker furnace problem
by wrecknician- Replies
- 22
- Views
- 10,477
The general 90 board, first generation 50a50 only...
The general 90 board, first generation 50a50 only has 5 code flashes, A code of 6 flashes means "call a more experiaced tech". Hope this helps....Wreck
Flame sensor failure. -
02-16-2005, 05:17 AM
- Replies
- 12
- Views
- 1,080
Could not see your pics on the post. I would...
Could not see your pics on the post.
I would need a M# S#.
ICP had a 14 seer unit with an equalization tube for the heating cycle.
It did not work well. You need to contact ICP if you are a... -
01-29-2005, 06:19 PM
Thread: Carrier GF
by wrecknician- Replies
- 2
- Views
- 1,222
got it,thanks
got it,thanks
-
01-29-2005, 12:56 PM
Thread: Carrier GF
by wrecknician- Replies
- 2
- Views
- 1,222
I have a tech working on a 58EFA050-GC, was it...
I have a tech working on a 58EFA050-GC, was it capable of being intsalled downfow??? thanks Wreck
-
02-23-2004, 06:55 PM
Thread: bypassed humidifier
by wrecknician- Replies
- 2
- Views
- 2,169
http://home.earthlink.net/~cpeckgo/DSC00034.JPG ...
http://home.earthlink.net/~cpeckgo/DSC00034.JPG
this Scuttle steam is beyond all of the takeoffs save one on this supply plenum, The one rin of duct that is actually being fed is a 100 Sq.Ft....
Results 1 to 10 of 20