Search:

Type: Posts; User: eduardo grueso

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Replies
    11
    Views
    1,043

    They are not all as bad or as ugly as the one in...

    They are not all as bad or as ugly as the one in the mirror
  2. Replies
    11
    Views
    1,043

    I started reading this thread late, but it sure...

    I started reading this thread late, but it sure is nice when the person who starts the thread comes back with an update on what the final problem and solution was.
  3. Replies
    4
    Views
    550

    Got to be cool to be a mod

    Got to be cool to be a mod
  4. I like refrtech and the absorber guy, they really...

    I like refrtech and the absorber guy, they really helped me out in a jam. I like the hvacpope guy too but not in that way.
  5. Replies
    54
    Views
    4,272

    I want to thank you guys for all your help...

    I want to thank you guys for all your help especially refrtech, the boss was so impressed with me I even got a 5 dollar an hour raise.

    I was so scared I was going to get fired, but being able to...
  6. Replies
    54
    Views
    4,272

    Thank you everyone for your help and support....

    Thank you everyone for your help and support. What a long night. Well we got it running, just in time too, the big boss walked in around an hour after we started it up. He was very impressed with me...
  7. Replies
    54
    Views
    4,272

    We jumped out a low something, im not sure what...

    We jumped out a low something, im not sure what it did but we think it was bad. It kept shutting the chiller off.
  8. Replies
    54
    Views
    4,272

    That is not nice reftech. I am just looking for...

    That is not nice reftech. I am just looking for help.
  9. Replies
    54
    Views
    4,272

    The plumber say he can fix the leak by putting...

    The plumber say he can fix the leak by putting some kind of plate or a cap on it. He says it should run then. It left some kind of oily stuff on the floor.
  10. Replies
    54
    Views
    4,272

    The chiller wont start now, the breaker keeps...

    The chiller wont start now, the breaker keeps getting stuck in the middle. Our electrician says its bad.
  11. Replies
    54
    Views
    4,272

    The other 2 chillers seem to be doing ok. I found...

    The other 2 chillers seem to be doing ok. I found out from the operater that these are 900 ton cvhe chillers. I just need to get the leak fixed by the morning.
  12. Replies
    54
    Views
    4,272

    How big? I got to get it fixed before the big...

    How big? I got to get it fixed before the big boss comes in in the morning. I hope I dont lose my job over this.
  13. Replies
    54
    Views
    4,272

    Well the operator wanted colder water, so we were...

    Well the operator wanted colder water, so we were trying to get it down to 28f. It kept going of on some kind of reset so we figured it was bad and jumped it out. Thats when the water started comming...
  14. Replies
    54
    Views
    4,272

    The water just keeps comming out the end. I think...

    The water just keeps comming out the end. I think its the reief valve but I dont see anyplace to shut it off.
  15. Replies
    54
    Views
    4,272

    I just got a new job. Ive never seen one before....

    I just got a new job. Ive never seen one before. But I am the in house mainanence guy now. We dont want to have the manufacturer in becuase they charge us way too much. Anyways the chiller is beige...
  16. Replies
    8
    Views
    1,125

    Sorry, just nit picking on a technicality. You...

    Sorry, just nit picking on a technicality.

    You could have hot or warm outdoor air in Arizona touching an uninsulated duct and nothing would sweat.

    You could have humid air, at 68 degrees touch...
  17. Replies
    8
    Views
    1,125

    Sweating has nothing to do with warm air touching...

    Sweating has nothing to do with warm air touching something cold. It is about humid air touching a cool surface.

    Many northern houses have un-insultated ductwork and no condensation when running...
  18. Replies
    5
    Views
    724

    If you could keep an air handler on the second...

    If you could keep an air handler on the second floor in a conditioned space you could have one with a heating and cooling coil.

    A hot water coil allows warm air heat, a second cooling coil in the...
  19. Replies
    6
    Views
    1,735

    Geenheck

    Geenheck
  20. Replies
    150
    Views
    45,513

    I would agree that an overcharge would raise...

    I would agree that an overcharge would raise suction pressure and SST. I do not believe an overcharge will cause icing up like you will see with an undercharge.

    Low airflow is another story but...
  21. Replies
    4
    Views
    866

    You should be able to treat the mainfloor as...

    You should be able to treat the mainfloor as being above an unconditioned space at the temperature you figure that basement will be in the dead of winter.You would also have to enter the 55 or 60...
  22. Replies
    24
    Views
    1,734

    Re: Hi Andy.

    Those radiant tube heaters are a great idea, you do not have to worry about dust. If they were building the shop from scratch radiant floor would be good, however it would not be as convenient if the...
  23. To bud in late, it sounds as if the unit keeps...

    To bud in late, it sounds as if the unit keeps humidity in check and the only real complaint is how fast a bucket used to fill.
  24. Replies
    49
    Views
    3,270

    I am saving my money for a big weber

    I am saving my money for a big weber
Results 1 to 24 of 26
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event