  1. Thread: NAE Problem

    by DST-Tech
    Replies
    14
    Views
    1,156

    Does the NUT have specific files for the version...

    Does the NUT have specific files for the version running on the NAE? We are running 4.1.4500 on our controllers at this site? Do I have to get the proper files to flash the controller? Thanks...
  2. Thread: NAE Problem

    by DST-Tech
    Replies
    14
    Views
    1,156

    Copied over the new xml file and made some...

    Copied over the new xml file and made some progress. I do not get the initial error. It allows me to enter my login information, but once it gets to 75%, it stops, then gives me a new error,"The...
  3. Thread: NAE Problem

    by DST-Tech
    Replies
    14
    Views
    1,156

    I'm getting it now. Thanks, I'll let you know...

    I'm getting it now. Thanks, I'll let you know what happens.
  4. Thread: NAE Problem

    by DST-Tech
    Replies
    14
    Views
    1,156

    I went through the PC that has SCT, but do not...

    I went through the PC that has SCT, but do not see any SecurityDB folder. I also searched the XML files and don;t see anything related to security. When I am back on the site, I will remote into...
  5. Thread: NAE Problem

    by DST-Tech
    Replies
    14
    Views
    1,156

    I tried doing that a few times, doesn't make a...

    I tried doing that a few times, doesn't make a difference. Also used another computer and I get the same Error Window. The error window opens just as the java window says "initializing...
  6. Thread: NAE Problem

    by DST-Tech
    Replies
    14
    Views
    1,156

    I am able to get into the NAE using Remote...

    I am able to get into the NAE using Remote Desktop Connection and can run explorer once the command window opens. I am not sure what to do next. There is a folder called SecurityDB in the root and...
  7. Thread: NAE Problem

    by DST-Tech
    Replies
    14
    Views
    1,156

    I do not have access to the local OEM people and...

    I do not have access to the local OEM people and that is not an option for me. I have limited tools available to me, just my PC. I found some other information searching the archives, so I will try...
  8. Thread: NAE Problem

    by DST-Tech
    Replies
    14
    Views
    1,156

    NAE Problem

    I have an NAE55 at version 4.1 that we are working on in the shop for testing purposes. All of a sudden, I cannot log into the device with the standard Metasys password. The PC has SCT on it and...
  9. Sorry for the late response. Been busy. I sent...

    Sorry for the late response. Been busy. I sent you an email with an Assembly. It is simple and has the functionality that I mentioned. From your questions above, I believe the System Resources...
  10. I have many systems running using the RTC doing...

    I have many systems running using the RTC doing Lead Lag in the FX. I have not utilized an outside schedule. We rotate Leads every Monday. We have a lot of two and three pump setups like this. ...
  11. It's hard to say definitively, but I would think...

    It's hard to say definitively, but I would think that if the timer is in its cycle and someone changes the setpoint, this could possibly affect the timer. I know that these timers have issues with...
  12. In that case, you could make a Schedule in the...

    In that case, you could make a Schedule in the FX60 and they can change the schedule if they want. You would then have the schedule trigger your switch point going into your logic. There are many...
  13. I have done lead lag a couple of different ways,...

    I have done lead lag a couple of different ways, using PLC and in one case using some logic blocks. Sometimes the timers act strange in the FX. Try this: First, you need a System Resources Block...
  14. How are you doing your Lead-Lag? Are you using...

    How are you doing your Lead-Lag? Are you using PLC? What is your trigger event to call the switch under normal conditions? Like, every Monday at 7 am.
  15. The pilot_status snvt 10160 has pre-defined...

    The pilot_status snvt 10160 has pre-defined states. Usually 255 is a null condition. State 0 is defined as pilot_auto, State 4 is defined as pilot_on and State 5 is defined as pilot_off. That is...
  16. Try it, you'll like it. You should use the bits...

    Try it, you'll like it. You should use the bits as specified, since these are what the controller recognizes. The bits have their default names, which also works, but putting in more familiar User...
  17. Replies
    15
    Views
    3,013

    You should be able to connect your laptop to your...

    You should be able to connect your laptop to your network and upload the ADS through the SCT. As stated here, I don't think you can re-download the NAE at 4.1 after saving the database under 5.2 on...
  18. Replies
    8
    Views
    705

    I am in Northern NJ, but all of our work is in...

    I am in Northern NJ, but all of our work is in NYC and Brooklyn.
  19. Replies
    8
    Views
    705

    In our marketplace, there is everything from JCI...

    In our marketplace, there is everything from JCI to Siemens, to Andover, to Automated Logic, etc., etc. Most of the larger manufacturers, like Siemens and JCI keep things real close to home. ...
  20. Replies
    8
    Views
    705

    Hardware Recommendations

    I have been working with JCI hardware/software for around 25 years now and am not satisfied overall with the quality and support of the newer products, starting with the FX control line. By the time...
  21. Replies
    13
    Views
    1,321

    We are using relays. It has been a habit ever...

    We are using relays. It has been a habit ever since DXs came out with all Triacs on their DOs. We are also driving multiple valves from each box, so relays were a must. I will be on site myself in...
  22. Replies
    13
    Views
    1,321

    The AHU does have heating and cooling, typical...

    The AHU does have heating and cooling, typical mixed air AHU with enthalpy economizer. Seems that we also have another issue with the PCV. Three of the sixteen control Fin Tube Radiation zones. ...
  23. Replies
    13
    Views
    1,321

    Working on one now. I deleted and brought the...

    Working on one now. I deleted and brought the point back as Writable and it takes the command. I did not get the Write error on this box. I told it to go into Cooldown Mode and the box states that...
  24. Replies
    13
    Views
    1,321

    I think we tried writing to that point as it...

    I think we tried writing to that point as it shows up as a Boolean Writable, but it went into Fault until we removed our command. There's got to be a way to do it; we will keep trying until it...
  25. Replies
    13
    Views
    1,321

    FX-PCV1620 question

    We are currently commissioning a job that has 16 VAV's with reheat using the FX-PCV controllers. We also have an FX16 controller running the AHU. We are supposed to be using a Warmup-Cooldown mode...
  26. Replies
    6
    Views
    864

    This particular trunk is also pretty long. The...

    This particular trunk is also pretty long. The FX60 runs the entire building, 45 stories to the top; all of the plant equipment below grade, plus a few small AHUs, then the towers at the top of the...
  27. Replies
    6
    Views
    864

    Items 1 & 2 are OK. I did not realize that a...

    Items 1 & 2 are OK. I did not realize that a repeater would be needed for more than 32 devices. Right now, the network seems stable with 31 controllers on it. That would make sense, because we had...
  28. Replies
    6
    Views
    864

    I don't think so. As each device was addressed,...

    I don't think so. As each device was addressed, the "Device ID" was also set to the address, but in the 57000 range. So, address 16 is 57016, 17 is 57017 and so on. I am assuming that this relates...
  29. Replies
    6
    Views
    864

    Onicon System 10 MS/TP issues on FX60

    We have one of our customers where we are setting up some Onicon System 10 BTU meters. They are on a separate stand-alone loop right now and when we connect them to the existing FX60 BACnet MS/TP...
  30. I did not read your entire post at first;...

    I did not read your entire post at first; selective reading. Try setting up your Override point into the DO on the override input as a SNVT 10160. Then, clear all of the bits, but select only...
  31. Replies
    14
    Views
    1,944

    They used to call it Builder Express. But as...

    They used to call it Builder Express. But as mentioned, they program all the Q&A that's possible into them, so when you select what you want, the program includes the stuff you want. I had to modify...
  32. The only time I have had something similar happen...

    The only time I have had something similar happen is when the bus was not terminated properly with EOL resistors. I build overrides into every program and have never seen that happen specifically. ...
  33. Replies
    2
    Views
    1,178

    Thanks for the link. It has some great...

    Thanks for the link. It has some great information. My main concern is how do we physically connect from the JACE to the NetController? Am I using the JACE serial port or making a cable from the...
  34. Replies
    2
    Views
    1,178

    Andover Infinet/Continuum to Tridium

    I have a customer that has an Andover NetController running a network of around 100 field controllers, a mix of VAVs and Fan Coils, using Infinet. Their front end has finally crashed and they are...
  35. Replies
    8
    Views
    836

    There are several other GE devices I believe that...

    There are several other GE devices I believe that are providing data to the Field Server. If I change its IP address, it may not be able to communicate with the other devices. Once we replace the...
  36. Replies
    8
    Views
    836

    I have configured routers before and I understand...

    I have configured routers before and I understand that the translation is going from the WAN to the LAN. I have never setup a Field Server and do not want to mess with it unless absolutely...
  37. Replies
    8
    Views
    836

    I also asked the same question about the device. ...

    I also asked the same question about the device. It is a Field Server and I don't know if the limitation is there or with the other stuff it is collecting data from. I personally think it is the...
  38. Replies
    8
    Views
    836

    ADX/NAE IP Routing

    We currently have an ADX and several NAE's on a dedicated LAN, using Static Addressing. One of the NAE's was setup to bring in some BACnet IP points from third party controllers onto the system for...
  39. Replies
    2
    Views
    837

    Thanks. Got it to work. Why didn't I think of...

    Thanks. Got it to work. Why didn't I think of that.
  40. Replies
    2
    Views
    837

    FX Comm Pro N2 Open

    We have been running FX tools on various laptops without problems, but most of them are XP based. We have just setup a Win 7 Pro 32 bit laptop and am having trouble getting the N2 Comm Pro to work. ...
  41. Replies
    1
    Views
    681

    Metasys ADX Remote Access

    We have requested remote access to an ADX on one of our customers' sites. The IT people did a security scan and requested that we apply a windows patch to Win 2003 Server and secondly disable FTP. ...
  42. Replies
    4
    Views
    613

    Somehow, I finally got it to work. I basically...

    Somehow, I finally got it to work. I basically put the points through the Niagara Network, but had to pull them through the Server. I could not directly discover the FX60 points through the FX70. ...
  43. Replies
    4
    Views
    613

    How do you create the new converted point in the...

    How do you create the new converted point in the FX60? I added a new point to the FX-7 as a boolean and gave it a fictitious address, like BD-100. It looks as if it is communicating, and I was able...
  44. Replies
    4
    Views
    613

    FX Server Link question

    I have a customer that currently has two FX70s and one FX60, connected to the facility network with an FX Server. I have an FX-7 controller on the FX60 where I am trying to send an enumerated point...
  45. Replies
    10
    Views
    1,022

    There is no archive OWS on site. The GPL can...

    There is no archive OWS on site. The GPL can still be compiled and downloaded via laptop if needed. I understand what you are saying about the NC requiring downloads, if necessary. The JCI...
  46. Replies
    10
    Views
    1,022

    I have done a little more homework on it and...

    I have done a little more homework on it and managed to get into the system the other day. I was able to setup a newer laptop with XP Pro and loaded PMI 12.03 onto it. Once I got into the system, I...
  47. Replies
    10
    Views
    1,034

    Thanks for the information. I am still learning...

    Thanks for the information. I am still learning every day. This product is so deep and offers a lot of flexibility. That's the good thing about the trade. You always have to keep yourself moving...
  48. Replies
    10
    Views
    1,022

    I do remember doing that and also that everything...

    I do remember doing that and also that everything will be in the systems directory. Thanks for waking up that part of my brain. I believe I still have a copy of the last PMI. Do you know if it...
  49. Replies
    10
    Views
    1,022

    PMI was used to connect as a workstation on the...

    PMI was used to connect as a workstation on the network. I only want to be able to add points to the single NC. I know that you can configure the laptop to log on as an unconfigured workstation,...
  50. Replies
    10
    Views
    1,022

    Johnson NCM help

    We have several NCM's on a customer site that are connected to an NIE-85. I need to add points to one of the NCM's, but haven't done so for a few years. Can anyone point me in the right direction? ...