Search:

Type: Posts; User: gje1

Page 1 of 8 1 2 3 4

Search: Search took 0.01 seconds.

  1. Thread: chat room

    by gje1
    Replies
    13
    Views
    4,113

    HVAC PRO(s) FORUM(s) such as this one have cool...

    HVAC PRO(s) FORUM(s) such as this one have cool idea's and extremely intelligent people who have a world of knowledge to share. Free to register like this one. Hope you can find the way to chat.
  2. Replies
    5
    Views
    1,407

    Mike, Did you register as Professional member?...

    Mike,

    Did you register as Professional member? Post your problems on the "Pro Tech" forum. You'll get a better response. Try to add the model number or serial number on your post. Great job on the...
  3. Replies
    12
    Views
    1,394

    Thanks jtp

    Thanks jtp
  4. Replies
    12
    Views
    1,394

    Jtp sounds like you're a installer of gas logs....

    Jtp sounds like you're a installer of gas logs. Was wondering if it was acceptable to have a flex line inside the fire box? We've been having some problems with home owners and some contractors using...
  5. Replies
    12
    Views
    1,394

    works for me Mike

    works for me Mike
  6. Thread: power outages

    by gje1
    Replies
    10
    Views
    899

    Hope you have a good one Mike. See you when you...

    Hope you have a good one Mike. See you when you get back. I know you took your laptop with you, so you'll be checking in from time to time. Looks like we're almost out of this so it should be cool up...
  7. Thread: power outages

    by gje1
    Replies
    10
    Views
    899

    Hey Snipe. Were you a boilerman in the navy?

    Hey Snipe. Were you a boilerman in the navy?
  8. Replies
    54
    Views
    5,009

    Water heater vent pipe needs a raise of 1" per...

    Water heater vent pipe needs a raise of 1" per foot. Yours looks like its horizontal to "Y". You may have some venting problems with the inducer fan running and water heater burner inoperation. I'm...
  9. Replies
    53
    Views
    2,772

    Did her shirt say inflate to 60 psi?

    Did her shirt say inflate to 60 psi?
  10. Replies
    23
    Views
    1,535

    Just like what some have posted 42. Bad HX....

    Just like what some have posted 42. Bad HX. Blowing the flame back out when fan starts. That's what those flameroll out switches are for. They work great, don't they?
  11. Replies
    4
    Views
    910

    jbtecnico1, Don't go to Home Depot and...

    jbtecnico1,

    Don't go to Home Depot and purchase ceramic logs and install them with that log lighter burner. It is not designed to run continuously with decorative logs. Make sure you do your...
  12. Thread: Gas Vs Wood

    by gje1
    Replies
    3
    Views
    1,124

    Pellit stove. Even the EPA likes them. check to...

    Pellit stove. Even the EPA likes them. check to make sure you can run the auger manually if power is lost. May be alittle expense up front but some have very high btu output. Nice thing about cutting...
  13. Replies
    7
    Views
    1,631

    If it has a cooling fan for the motor. Make sure...

    If it has a cooling fan for the motor. Make sure the fan is not coming in contact with the guard cage. You can correct this by pushing the fan back on is shaft away from the guard cage.
  14. Thread: Floor funnace

    by gje1
    Replies
    29
    Views
    1,958

    shouldn't you be in bed?

    shouldn't you be in bed?
  15. Thread: Floor funnace

    by gje1
    Replies
    29
    Views
    1,958

    Mike3 is probably right. It's got an obstruction...

    Mike3 is probably right. It's got an obstruction in the orifice and a spider web is a good bet. Removed a dozen myself. Mike3 has probably removed hundreds. Floor furnaces are not the easiest to get...
  16. Replies
    5
    Views
    1,070

    Williams makes a decorative log wall furnace....

    Williams makes a decorative log wall furnace. Kind of cool. You might want to check into a Coleman or Kenmore counterflow wall furnace. Fans circulate air from top to bottom of furnace. Very...
  17. Thread: gas valve

    by gje1
    Replies
    15
    Views
    1,122

    Rookie 19, Calling the Gas Company to report a...

    Rookie 19,
    Calling the Gas Company to report a gas leak to have your furnace checked is like calling the Fire Department to report a fire when all you want is tickets to the next firemens ball. I...
  18. Replies
    15
    Views
    1,216

    BoldLoonie is right, but i would check the dip...

    BoldLoonie is right, but i would check the dip switches to make sure they are in the correct positions for 2 stage firing and not in high fire mode. See the owners manual. You should easily be able...
  19. Replies
    19
    Views
    2,163

    2 stage t-stat are nice and very expensive. You...

    2 stage t-stat are nice and very expensive. You can see by some posts, that some recommend a 2 stage t-stat. Yours should run fine on a single stage t-stat. See your owners manual and makse sure it...
  20. Replies
    20
    Views
    1,094

    That would be gje1,but it was close Mike.

    That would be gje1,but it was close Mike.
  21. Replies
    18
    Views
    3,874

    Better check owners manual to see if it's a self...

    Better check owners manual to see if it's a self adjusting heat anticipator or have someone adjust it. Should be some info on cycle times too.
  22. Thread: Gas Pressure

    by gje1
    Replies
    7
    Views
    958

    Did he adjust it up or down? Why was it out of...

    Did he adjust it up or down? Why was it out of adjustment it the first place? Yeah, great job in checking the pressure but if there is an obstruction in the orfices than when it becomes dislodge,...
  23. Replies
    22
    Views
    2,100

    Not sure this will help now but for the future....

    Not sure this will help now but for the future. Check this web site out. Got alot of nice stuff. http://www.govliquidation.com/index.html
    Good luck. Hope things turn out all right for you.
  24. Replies
    1
    Views
    780

    Replacing old furnace (Nat gas) and adding AC....

    Replacing old furnace (Nat gas) and adding AC. New furnace is a Carrier. Model # 58DLX090-14 80%. Compressor is a Carrier Performance Series 11-15 seer. House is 1400 sq ft has R30 insulation in...
  25. Thread: Copper gaslines

    by gje1
    Replies
    13
    Views
    1,735

    In the State of California, copper gas lines are...

    In the State of California, copper gas lines are illegal. However, there's talk about legalizing it again due to the fact that most sulfites have been removed from the Natural Gas. The verdict is...
Results 1 to 25 of 184
Page 1 of 8 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event