  1. Replies
    3
    Views
    1,500

    Wow, never realized great stuff was UL181 listed!...

    Wow, never realized great stuff was UL181 listed! :gah:
  2. Thread: New Boots

    by Miller257
    Replies
    15
    Views
    2,081

    Power was off, and how would it be any different...

    Power was off, and how would it be any different than a linesman in plastic bucket on a boom truck working on a live wire. I guess we could have let the building freeze...
  3. Thread: New Boots

    by Miller257
    Replies
    15
    Views
    2,081

    why would using buckets to prevent your feet from...

    why would using buckets to prevent your feet from getting wet get you a darwin award?
  4. Weld on a 1/4" coupling, thread on a ball valve,...

    Weld on a 1/4" coupling, thread on a ball valve, drill it out and shut the valve. then thread on a service port.
  5. Thread: New Boots

    by Miller257
    Replies
    15
    Views
    2,081

    Plumbing burst on the second floor, ran all the...

    Plumbing burst on the second floor, ran all the way down to the basement, where the floor drain was plugged. I think the wire is for a pump, as they pumped the water out instead of unclogging the...
  6. Replies
    4
    Views
    1,108

    I have the uniqure oppertunity of being a...

    I have the uniqure oppertunity of being a estimator project manager and engineer, I do the same, medium or high static drives. Upsize the drive on furnaces. the best thing in the world is the DC...
  7. Thread: New Boots

    by Miller257
    Replies
    15
    Views
    2,081

    New Boots

    My boss

    450161

    After all they they didn't get the floor drain unplugged! :Faint:
  8. Replies
    4
    Views
    1,108

    No, they installed the HVAC and we installed the...

    No, they installed the HVAC and we installed the kitchen hood.
  9. Replies
    4
    Views
    1,108

    It does not actually matter.

    Contractor to inspector;

    "I understand that the balancing report and results of air flow are nothing like the plans we submitted and that were approved through your office but it is my...
  10. Replies
    65
    Views
    5,326

    It's a quick easy way to cover your ass, If you...

    It's a quick easy way to cover your ass, If you do a PM, compressor runs fine, pressure and amps. Do a meg and megs kind of low, you can note it on your report.

    Nothing worse than doing a PM, and...
  11. Replies
    24
    Views
    3,281

    Inspector wanted it every marked every 5 feet. I...

    Inspector wanted it every marked every 5 feet. I went a little nuts...
  12. Replies
    65
    Views
    5,326

    It depends, typically 1.25 hours in spring, .75...

    It depends, typically 1.25 hours in spring, .75 hours in fall 25 tons and under.

    Spring;
    Clean coils
    check amp draws, meg out compressors
    check amp draws and meg out blower motors
    check all...
  13. Replies
    76
    Views
    3,469

    wow some of you guys throw a lot of hours on...

    wow some of you guys throw a lot of hours on there, cranes to get them on the roof. 24 hours???
  14. Replies
    12
    Views
    1,842

    I was agreeing with Marc, I tell all my guys to...

    I was agreeing with Marc, I tell all my guys to do it that way, not as pictured.
  15. Replies
    24
    Views
    3,281

    It's a commercial building, but we run 2 psi for...

    It's a commercial building, but we run 2 psi for everything. I put 2 psi in my house as well. I can run 1/2 CSST instead of 1-1/4 blackpipe.
  16. Replies
    12
    Views
    1,842

    That's the way I always do it.

    That's the way I always do it.
  17. Replies
    12
    Views
    1,842

    Is this wrong or not?

    I always go valve, trap, regulator, union, unit.

    Trap always on a change of direction....443141
  18. Replies
    24
    Views
    3,281

    This dives me nuts

    Some of my guys, Can't paint the 3' of rusty gas pipe going into the building on a brand new million dollar building.443131
  19. Replies
    11
    Views
    2,282

    by the looks of that unit, the A/C might have...

    by the looks of that unit, the A/C might have been there first :)
  20. Replies
    19
    Views
    4,453

    Who buries a lineset underground. I at least run...

    Who buries a lineset underground. I at least run them in PVC
  21. Replies
    19
    Views
    2,509

    better air flow

    better air flow
  22. Replies
    5
    Views
    1,075

    it may but it was not setup that way. 40ton...

    it may but it was not setup that way. 40ton luxaire :gah:
  23. Thread: P-Traps

    by Miller257
    Replies
    1
    Views
    1,216

    P-Traps

    427711427721427731

    Gotta love it.
  24. Replies
    5
    Views
    1,075

    No need for a 3H4C on a 40 ton

    427701

    Surprised they didn't put a single stage stat on it.
  25. Thread: Got fuse'?

    by Miller257
    Replies
    10
    Views
    1,928

    You guys have never seen these???

    You guys have never seen these???