  1. Replies
    0
    Views
    166

    quick-connect on Friedrich

    I just became aware of the Friedrich "Breeze" systems geared toward
    the DIY market, which evidently come with a pre-charged lineset
    and this wacky both-at-once quick connector with a big locking...
  2. Replies
    54
    Views
    4,954

    Am I allowed to ask this here? It's for another...

    Am I allowed to ask this here? It's for another "theory"
    clarification ... the various mentions that subcooling on
    the indoor coil in heating mode would generally be greater
    than [presumably...
  3. Thread: clearing a leak

    by hobbit
    Replies
    5
    Views
    460

    I think it's the drain because I saw a quick...

    I think it's the drain because I saw a quick video the owner
    had shot, showing the typical white PVC with a U-trap coming
    out of the unit and heading away and water dripping out of
    the box about...
  4. Thread: clearing a leak

    by hobbit
    Replies
    5
    Views
    460

    clearing a leak

    Hopefully this doesn't tread too close to DIY but I've got some
    friends who are in a pickle this warm Sunday evening and can't
    get anybody in until tomorrow. They've got an a/c unit in the
    attic...
  5. Replies
    7
    Views
    978

    Thanks for the responses so far! The end goal,...

    Thanks for the responses so far! The end goal, really, is simply
    determining whether to run my HP system on high fan or low fan
    in heating mode, and have broader perspective on the advantages
    or...
  6. Replies
    7
    Views
    978

    Heating airflow theory Q

    In the tradition of my little headscratchers which are either
    thought-provoking or totally stupid, I'm not sure which, here's
    another theory question. This would be a purely heating scenario,...
  7. Thread: Wet duct

    by hobbit
    Replies
    1
    Views
    383

    Wet duct

    Hopefully this doesn't tread too far toward DIY territory, but
    I've got a little problem with a cold-air intake that someone
    might have some insight into. You guys must deal with
    fresh-air inlet...
  8. Replies
    19
    Views
    2,318

    beenthere, that's awesome; a quick look at a...

    beenthere, that's awesome; a quick look at a psych chart makes
    it make sense, except that the chart I usually use only goes
    down to 20F. Still, clearly not a whole lot of grains to be
    had in air...
  9. Replies
    19
    Views
    2,318

    I'm aware of how the indoor and outdoor coils...

    I'm aware of how the indoor and outdoor coils have to swap functions,
    and even know exactly where my reversing valve is... what I'm trying to
    understand is what happens to subfreezing *air* when it...
  10. Replies
    19
    Views
    2,318

    cold weather operation

    I've got a couple of general questions about heat-pump operation
    in cold ambients. One practical, one more theory.

    Most units either have a crankcase heater or use the inverter to
    bleed about...
  11. Replies
    0
    Views
    521

    heat pump fan high or low?

    Swinging into heating season here, I'm wondering if it's better
    to run a heat pump's AHU blower at a higher or lower speed?
    While lower is better for summer dehumidification, if we're only...
  12. Replies
    16
    Views
    2,119

    Trust me, the second company will be who gets...

    Trust me, the second company will be who gets called next [unless
    I have an actual warranty issue] but really, with periodic simple
    care/cleaning that I can do myself I'm hoping to not have to call...
  13. Replies
    16
    Views
    2,119

    I don't know if it's better to follow up on a...

    I don't know if it's better to follow up on a really old thread
    or start a new one; I'll try it this way first.

    I finally had another service company come out and eyeball my
    Daikin setup and...
  14. Replies
    4
    Views
    611

    Yup, the Daikin FTQ type air handler. Quoting...

    Yup, the Daikin FTQ type air handler. Quoting from the
    install manual description for option block terminals 9,10:
    "Receives input: Forced closure of indoor unit Electronic
    Expansion Valve during...
  15. Replies
    4
    Views
    611

    EXV forced closure?

    I recently noticed that my air handler / indoor coil has a pair
    of dry-contact input terminals to force its EXV to CLOSED during
    cooling mode.

    When/why would you want to do this, and/or why...
  16. Replies
    0
    Views
    322

    Daikin: no emergency operation??

    I've run into what might be the first notable downside of a two-wire
    digital 'stat interface, as opposed to the typical W1/W2/Y/G/etc bundle
    of wires between a typical stat and an indoor unit. ...
  17. Replies
    6
    Views
    1,004

    That would all likely be true *IF* this rig had a...

    That would all likely be true *IF* this rig had a traditional stat.
    It doesn't. Daikin's big thing WRT control is two-wire data
    links -- one two-wire shot to the stat, and another one from the...
  18. Replies
    13
    Views
    2,237

    It finally got warm enough again that I was able...

    It finally got warm enough again that I was able to get the coil loaded
    up and try to take a CFM measurement. The filter slot opening is
    about the same dimension as the main return duct, so I pull...
  19. Replies
    6
    Views
    1,004

    I did have that thought ... except that OAT can't...

    I did have that thought ... except that OAT can't be measured if the
    outdoor unit doesn't have power anyway. The scenario I'm thinking
    is indoor AHU powered, outdoor unit dead ... I should still...
  20. Replies
    6
    Views
    1,004

    when does emergency/backup heat kick in

    This is kind of a general question and the specifics for particular
    brands/units might be all over the place. I'm in New England, where
    we have ice storms and weird "snowpocalypse" events and...
  21. Replies
    13
    Views
    2,237

    That's about what I was thinking, re: COP. The...

    That's about what I was thinking, re: COP. The outdoor unit was
    drawing all of 3 or 4 amps at 240V, less than a kilowatt for several
    hours. This particular experiment went on fairly far into the...
  22. Replies
    13
    Views
    2,237

    another silly psych question

    No, this isn't about my "macguyvered" windowshaker-turned-dehum; that's
    been put away for the moment because the real system is doing so much
    better at water removal. So I've been studying that a...
  23. Replies
    10
    Views
    2,220

    Sorry, it probably came out a little wrong as can...

    Sorry, it probably came out a little wrong as can often happen in
    email. And yes, the spam-filters are pretty strict over here, but
    the rejection should have indicated something about why it...
  24. Replies
    10
    Views
    2,220

    Hmm. That's one of the issues, finding someone...

    Hmm. That's one of the issues, finding someone who is willing to
    do all that due diligence. The guy who installed this rig for me
    apparently isn't.

    It probably seems like I'm going too hard on...
  25. Replies
    10
    Views
    2,220

    Okay, good to know about the PVE -- the Daikin...

    Okay, good to know about the PVE -- the Daikin doc never mentions
    anything about oil type one way or the other, and I just assumed it was
    POE. Having studied automotive coolant and brake-fluid...